Part Number Hot Search : 
6TPE100 75A54E SPIC33 M5240 BCR16 1N4002G D1204 10022054
Product Description
Full Text Search
  gamewell-fci Datasheet PDF File

For gamewell-fci Found Datasheets File :: 144    Search Time::1.031ms    
Page :: | 1 | 2 | 3 | 4 | 5 | 6 | <7> | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

    MS95-DL MS95-SL BG-TR

Gamewell-FCI by Honeywell
Part No. MS95-DL MS95-SL BG-TR
OCR Text gamewell-fci MS95-L Series is a state-of-the-art, single- or dual-action XP95 pull station that includes an XP95 addressable interface for any gamewell-fci 600 Series Fire Alarm Control Panel (FACP). Because the MS95-L Series is addressable...
Description Addressable XP95 Manual Pull Stations

File Size 440.96K  /  2 Page

View it Online

Download Datasheet





    MS95-SD MS95-SS

Gamewell-FCI by Honeywell
Part No. MS95-SD MS95-SS
OCR Text Gamewell MS95-S Series is a state-of-the-art, single- or dualaction pull station that includes an addressable interface for any Gamewell 600...FCI 12 Clintonville Road Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell...
Description Addressable Manual Pull Station with SmartScan

File Size 118.43K  /  2 Page

View it Online

Download Datasheet

    XP95-LI

Gamewell-FCI by Honeywell
Part No. XP95-LI
OCR Text gamewell-fci analog addressable systems can be wired as Style 7 (Class A) closed-loop systems. These systems can be interrogated from either end so that all devices can remain in operation if an open circuit fault in the wiring occurs. A sh...
Description Analog XP95 line isolator with mounting base

File Size 66.45K  /  2 Page

View it Online

Download Datasheet

    BCD BCE-95

Gamewell-FCI by Honeywell
Part No. BCD BCE-95
OCR Text gamewell-fci's Building Control Element (BCE-95) is the interface between the IF632 or IF650 Fire Alarm Control Panel (FACP) and building functions that require a three position (HOA) (On/Off/Auto) control capability. The BCE95 connects to ...
Description Building control element device

File Size 69.12K  /  2 Page

View it Online

Download Datasheet

    M46-SL M46-OL M46-OLB M46-DL

Gamewell-FCI by Honeywell
Part No. M46-SL M46-OL M46-OLB M46-DL
OCR Text gamewell-fci M46-L Series is a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications used by the installer and end-user. The M46-L Series features a variety of mode...
Description Conventional Fire Alarm Pull Stations

File Size 208.38K  /  2 Page

View it Online

Download Datasheet

    ADB-FL ASD-LS B224BI RA-400Z

Gamewell-FCI by Honeywell
Part No. ADB-FL ASD-LS B224BI RA-400Z
OCR Text ...no responsibility is assumed by gamewell-fci for their use. Specifications subject to change without notice. (c) 2006 All Rights Reserved gamewell-fci 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 Fax: (203) 484-7118 ww...
Description Low Profile Analog Laser Sensor

File Size 48.91K  /  2 Page

View it Online

Download Datasheet

    BEAMLRK BEAMSMK ABD-RT2F RTS451 RTS451KEY ABD-2F

Gamewell-FCI by Honeywell
http://
Gamewell-FCI by Honeywe...
Part No. BEAMLRK BEAMSMK ABD-RT2F RTS451 RTS451KEY ABD-2F
OCR Text gamewell-fci VelocitiTM Series, ABD-2F and addressable projected beam smoke sensor is uniquely suited to sense smoke in hostile environments or open areas with high ceilings where spot-type sensors are unsuitable or difficult to install and...
Description Single-ended reflected type beam smoke sensor

File Size 60.67K  /  2 Page

View it Online

Download Datasheet

    MPS-8

Gamewell-FCI by Honeywell
Part No. MPS-8
OCR Text gamewell-fci's 600 Series power supplies, the MPS-8 and the APS-8, have been developed for today's critical power requirements that demand high efficiency and outstanding reliability. The extensive use of audio/visual devices for ADA signal...
Description Main power supply, complete with lead acid battery chrger module

File Size 102.89K  /  2 Page

View it Online

Download Datasheet

    70896-02 70896-05 70896-10 XP95-I XP95-ID XP95-IDR XP95-P XP95-PD XP95-PDR 30203-01 30007-02

Gamewell-FCI by Honeywell
Gamewell-FCI by Honeywe...
Part No. 70896-02 70896-05 70896-10 XP95-I XP95-ID XP95-IDR XP95-P XP95-PD XP95-PDR 30203-01 30007-02
OCR Text gamewell-fci analog addressable duct smoke detectors provide early detection of smoke and products with combustion present in air moving through an HVAC duct. Fans, blowers and complete systems may be shut down or activated in fire alarm mo...
Description Analog Addressable Duct Smoke Detectors

File Size 243.19K  /  2 Page

View it Online

Download Datasheet

    2151 RA-400Z PAM-1

Gamewell-FCI by Honeywell
Part No. 2151 RA-400Z PAM-1
OCR Text ...inches (4.2 cm) 3.6 oz. (104 g) gamewell-fci 12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to cha...
Description Photoelectronic detector

File Size 81.55K  /  2 Page

View it Online

Download Datasheet

For gamewell-fci Found Datasheets File :: 144    Search Time::1.031ms    
Page :: | 1 | 2 | 3 | 4 | 5 | 6 | <7> | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

▲Up To Search▲

 




Price and Availability




 
Price & Availability of gamewell-fci

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X
0.40362191200256