List of Unclassifed Man...
|
Part No. |
SU6000RT3UHV
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v ac output 20 minutes runtime at half load (2100w) / 8 minutes at full load (4200w) with included bp240v7rt3u external battery pack expandable runtime with multiple external battery packs inno... |
Description |
SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240v Hardwire output
|
File Size |
527.50K /
7 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
PDUMH20HVATNET
|
OCR Text |
...c19 output nominal voltage 200; 208; 220; 230; 240 overload protection n/a customized load management receptacles 8 individually switched c13 output receptacles input pdu input voltage 200; 208; 220; 230; 240 recommended electrical service ... |
Description |
3.2-3.8kW Single-Phase ATS/Switched PDU, LX Platform Interface, 200-240v Outlets (8 C13 & 2 C19), 2 C20, 12ft Cord, 1U Rack-Mount, TAA
|
File Size |
153.54K /
4 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SUINT3000LCD2U
|
OCR Text |
208/230v 3kva 2.7kw double- conversion ups, 2u rack/tower, extended run, network card slot, lcd, usb, db9 model number: suint3000lcd2u high-...220/230/240v output voltage l 3000va/2700w capacity l highlights zero transfer time suitable for adv... |
Description |
SmartOnline 208/230V 3kVA 2.7kW Double-Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9
|
File Size |
167.98K /
7 Page |
View
it Online |
Download Datasheet
|
|
|
 |

http:// Altech corporation
|
Part No. |
GMD-80001C GMD-80001F GMD-80001P GMD-80010C GMD-80010F GMD-80010P GMD-800C GMD-800F GMD-800M01C GMD-800M01F GMD-800M01P GMD-800M10C GMD-800M10F GTK-600 GTK-6003 GTK-600H GTK-600H3 GTK-600M GTK-600M3 GTK-600MH GTK-600MH3 GMC-80001C GMC-80001F GMC-80001P GMC-80010C GMC-80010F GMC-80010P GMC-800C GMC-800F GMC-800M01C GMC-800M01F GMC-800M01P GMC-800M10C GMC-800M10F GMC-800M10P GMC-800MC GMC-800MF GMC-800MP GMC-800P GMC-600M01C GMD-600M01C GMC-600M01F GMD-600M01F GMC-600M01P GMD-600M01P GMC-600M10C GMD-600M10C GMC-600M10F GMD-600M10F GMC-600M10P GMD-600M10P GMC-901C GMC-901F GMC-901P GMC-60001P GMD-60001P GTK-22 GTK-223 GTK-22H GTK-22H3 GTK-22M GTK-22M3 GTK-22MH GTK-22MH3 GMC-60001C GMD-60001C GMC-60001F GMD-60001F GMD-9F GMC-60010C GMC-60010F GMC-60010P GMC-600C GMC-600F GMC-600MP GMD-600MP GTK-12 GTK-12MH GTH-22 GTH-223 GTH-22H GTH-22H3 GTH-22M GTH-22M3 GTH-22MH GTH-22MH3 GMD-901C GMD-901F GMD-901P GMD-910C GMD-910F GMD-910P GMD-9C GMD-9M01C GMD-9M01F GMD-9M01P GMD-9M10C GMD-9M10F GMD-9M10P GMD-9MC GMD-9MF GMD-9MP GMD-9P GMC-601C GMC-601F GMC-601P GTH-12 GTH-123 GTH-12H GTH-12H3 GTH-12M GTH-12M3 GTH-12MH GTH-12MH3 GMD-610C GMD-610F GMD-610P GTH-600 GTH-6003 GTH-600H GTH-600H3 GTH-600M
|
OCR Text |
...32
AC: 24, 42, 48, 110, 120, 208, 220, 240, 277, 380, 440, 480, 600V DC: 12, 20, 24, 48, 60, 80, 100, 110, 125, 200, 220, 250V Ordering Example: GMC-9-AC120V (see also page 6)
Additional Auxiliary Contacts
Configuration 2 N.O. 2 N.C.... |
Description |
Contactors (9 to 85A) Frame size
|
File Size |
864.11K /
14 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU16KRTHW
|
OCR Text |
...pports north american (l1,l2,g) 208/240v hardwire input / output, plus international 230/220/240v (l,n,pe) hardwire input / output optional su6000xfmr2u transformer offers 120v output in north american 208/240v (l1,l2,g) input configuration... |
Description |
SmartOnline 200-240v, 16kVA 14.4kW On-Line Double-Conversion UPS, N 1, Extended Run,SNMP, Webcard, 12U Rack-Tower, USB, DB9 Serial,Hardwire
|
File Size |
557.51K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU16KRTG
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v nominal supports 50/60hz operation for worldwide frequency compatibility expandable runtime with optional external battery packs some external battery configurations require the use of tripp ... |
Description |
SmartOnline 200-240v 16kVA 14.4kW On-Line Double-Conversion UPS, N 1, Extended Run,SNMP, Webcard, 12U Rack-Tower, USB, DB9 Serial,C19 Outlets
|
File Size |
559.69K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU20KRTHW
|
OCR Text |
...pports north american (l1,l2,g) 208/240v hardwire input / output, plus international 230/220/240v (l,n,pe) hardwire input / output optional su6000xfmr2u transformer offers 120v output in north american 208/240v (l1,l2,g) input configuration... |
Description |
SmartOnline 200-240v, 20kVA 18kW On-Line Double-Conversion UPS, N 1, Extended Run,SNMP, Webcard, 12U Rack-Tower, USB, DB9 Serial,Hardwire
|
File Size |
558.01K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU20KRTG
|
OCR Text |
...put within 2% of selectable 200/208/220/230/240v nominal supports 50/60hz operation for worldwide frequency compatibility expandable runtime with optional external battery packs some external battery configurations require the use of tripp ... |
Description |
SmartOnline 200-240v 20kVA 18kW On-Line Double-Conversion UPS, N 1, Extended Run,SNMP, Webcard, 12U Rack-Tower, USB, DB9 Serial,C19
|
File Size |
558.51K /
6 Page |
View
it Online |
Download Datasheet
|
|
|
 |
Tripp Lite. All Rights ...
|
Part No. |
SU8000RT3UHW-15
|
OCR Text |
...pports north american (l1,l2,g) 208/240v hardwire input / output, plus international 230/220/240v (l,n,pe) hardwire input / output optional su6000xfmr2u transformer offers 120v output in north american 208/240v (l1,l2,g) input configuration... |
Description |
SmartOnline 200-240v 8kVA 7.2kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 6U Rack/Tower, Bypass Switch, Hardwire
|
File Size |
541.27K /
6 Page |
View
it Online |
Download Datasheet
|
For