If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
CR04AM Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts OUTLINE DRAWING B B A Description: The Powerex CR04AM Lead Mounted, Phase Control SCRs are glass-passivated thyristors for use in low power control and rectification. These devices are molded silicone plastic types. Features: Glass Passivation Short Turn-on Time - Suitable to Pulse Use Applications: Phase Control Triggering of High Power Thyristors, Pulse Generators and Counters Static Switch Motor Control Strobe Flasher Outline Drawing (Conforms to JEDEC TO-92) Dimensions A B C D E F Inches 0.5 Min. 0.20 Max. 0.15 Max. 0.05 0.05 0.028 Dia. Millimeters 12.5 Min. 5.0 Max. 3.9 Max. 1.3 1.25 0.7 Dia. Type CR04AM E E CIRCUMSCRIBE CIRCLE F - DIA. D C CONNECTION DIAGRAM CATHODE ANODE GATE Ordering Information: Example: Select the complete seven or eight digit part number you desire from the table - i.e. CR04AM-8 is a 400 Volt, 0.4 Ampere Phase Control SCR. VDRM/VRRM Volts 400 600 Code -8 -12 P-11 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR04AM Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts Absolute Maximum Ratings, Ta = 25 C unless otherwise specified Ratings Repetitive Peak Off-state Voltage Repetitive Peak Reverse Voltage Non-repetitive Peak Reverse Voltage DC Reverse Voltage DC Forward Voltage RMS On-state Current Average On-state Current (Nominal, See Graphs) Ta = 54C I2t for Fusing, t = 8.3 msec Peak Gate Power Dissipation Average Gate Power Dissipation Peak Forward Gate Current Peak Forward Gate Voltage Peak Reverse Gate Voltage Storage Temperature Operating Temperature Weight Symbol VDRM VRRM VRSM VR(DC) VD(DC) IT(RMS) IT(avg) I2t PGM PG(avg) IFGM VFGM VRGM Tstg Tj - CR04AM-8 400 400 500 320 320 0.63 0.4 10 0.4 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 0.23 CR04AM-12 600 600 720 480 480 0.63 0.4 10 0.4 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 0.23 Units Volts Volts Volts Volts Volts Amperes Amperes Amperes A2sec Watts Watts Amperes Volts Volts C C Grams Non-repetitive Peak Surge, On-state Current One Cycle (60 Hz) ITSM P-12 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR04AM Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified Characteristics Voltage - Blocking State Peak Forward Leakage Peak Reverse Leakage Current - Conducting State Peak On-state Voltage DC Holding Current Thermal Resistance, Junction-to-ambient Gate - Parameters Gate Current to Trigger Gate Voltage to Trigger Non-triggering Gate Voltage I ,V GT GT Measurement Circuit Symbol IDRM IRRM VTM IH Rth(j-a) IGT VGT VGD Test Conditions Tj =125C, VD = VDRM Tj = 125C, VR = VRRM Ta = 25C, ITM = 1.2A VD = 12V, RGK = 1K , Tj = 25C - VD = 6V, RL = 60 , Tj = 25C VD = 6V, RL = 60 , Tj = 25C VD = 1/2VDRM, RGK = 1k , Tj = 125C Min. - - - - - 1 - 0.2 Typ. - - - 1.5 - - - - Max. 0.5 0.5 1.2 3.0 150 100 0.8 - Units mA mA Volts mA C/W A Volts Volts IGS A3 3V DC IGT A2 V1 VGT A1 TUT 60 6V DC RGK 1 2 1k SWITCH SWITCH 1: IGT Measurement SWITCH 2: VGT Measurement (Inner resistance of voltage meter is about 1k ) P-13 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR04AM Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts MAXIMUM ON-STATE CHARACTERISTICS INSTANTANEOUS ON-STATE VOLTAGE, VTM, (VOLTS) TRANSIENT THERMAL IMPEDANCE, Zth(j-a), (C/WATT) 5.0 Tj = 25oC 103 100 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-AMBIENT) 101 102 GATE CHARACTERISTICS 103 102 Tj = 25 GATE VOLTAGE, VG, (VOLTS) 4.0 101 VFGM = 6V PGM = 0.5W 102 3.0 PG(avg) = 0.1W 100 VGT = 0.8V IGT = 100 A 2.0 101 10-1 VGD = 0.2V 1.0 IFGM = 0.3A 0 10-1 100 101 102 100 10-3 10-2 TIME, t, (s) 10-1 100 10-2 10-2 10-1 100 101 102 103 INSTANTANEOUS ON-STATE CURRENT, ITM, (AMPERES) GATE CURRENT, IG, (mA) MAXIMUM SURGE CURRENT FOLLOWING RATED LOAD CONDITIONS MAXIMUM PEAK SURGE CURRENT, ITSM, (AMPERES) ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVEFORM) MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE HALF WAVEFORM) 10 160 MAXIMUM POWER DISSIPATION, (WATTS) 0.8 RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION 360 140 8 AMBIENT TEMPERATURE, Ta, (C) 0.7 = 30 60 90 120 180 120 100 80 90 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.2 RESISTIVE, INDUCTIVE LOADS 6 4 60 40 = 30 120 60 180 2 20 0 100 0 101 CYCLES AT 60 Hz 102 0 0.2 0.4 0.6 0.8 0.4 0.6 0.8 AVERAGE ON-STATE CURRENT, I T(avg), (AMPERES) AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE FULL WAVEFORM) MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE FULL WAVEFORM) MAXIMUM ALLOWABLE AMBIENT TEMPERATURE, Ta, (C) MAXIMUM ALLOWABLE AMBIENT TEMPERATURE (RECTANGULAR WAVEFORM) 160 MAXIMUM POWER DISSIPATION, (WATTS) 0.8 RESISTIVE LOADS NATURAL CONVECTION 360 160 140 120 100 80 60 40 20 = 30 DC 60 90 120 180 270 RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION 360 140 AMBIENT TEMPERATURE, Ta, (C) 0.7 = 30 120 100 80 60 90 0.6 0.5 0.4 0.3 0.2 0.1 120 60 90 180 40 20 = 30 60 120 180 RESISTIVE LOADS 360 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) 0 0 0.2 0.4 0.6 0.8 AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) 0 0 0.2 0.4 0.6 0.8 AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) P-14 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR04AM Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts MAXIMUM ON-STATE POWER DISSIPATION (RECTANGULAR WAVEFORM) GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL) 0.8 GATE TRIGGER CURRENT, (tC) x 100% GATE TRIGGER CURRENT, (25C) MAXIMUM POWER DISSIPATION, (WATTS) 103 GATE TRIGGER VOLTAGE, (tC) x 100% GATE TRIGGER VOLTAGE, (25C) 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 -40 -20 0 20 40 60 80 100 120 DISTRIBUTION TYPICAL EXAMPLE 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.2 120 180 270 = 30 60 90 DC 102 101 RESISTIVE, INDUCTIVE LOADS 360 100 0.4 0.6 0.8 -40 0 40 80 120 160 AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES) JUNCTION TEMPERATURE, Tj, (C) JUNCTION TEMPERATURE, Tj, (C) HOLDING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL) HOLDING CURRENT VS. GATE TRIGGER CURRENT HOLDING CURRENT VS. GATE-TO-CATHODE RESISTANCE (TYPICAL) 102 (RGK = 1k ) HOLDING CURRENT, IH, (mA) HOLDING CURRENT, IH, (mA) 4.0 Ta = 25C 500 x 100% HOLDING CURRENT, (RGK = 1k ) HOLDING CURRENT, (RGK = rk ) 3.5 3.0 2.5 2.0 1.5 1.0 0.5 400 101 DISTRIBUTION TYPICAL EXAMPLE 300 200 100 100 10-1 -40 0 40 80 120 160 JUNCTION TEMPERATURE, Tj, (C) 0 100 101 102 103 0 10-1 100 101 102 GATE TRIGGER CURRENT, IGT, (mA) GATE-TO-CATHODE RESISTANCE, RGK, (k ) BREAKOVER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL) BREAKOVER VOLTAGE VS. RATE OF RISE OF OFF-STATE VOLTAGE (TYPICAL) BREAKOVER VOLTAGE VS. GATE TO CATHODE RESISTANCE (TYPICAL) 160 RGK = 1k BREAKOVER VOLTAGE, (tC) x 100% BREAKOVER VOLTAGE, (25C) x 100% 160 140 120 100 80 60 40 20 0 100 101 102 103 EXPONENTIAL WAVE Tj = 125C RGK = 1k x 100% 160 140 120 100 80 60 40 20 0 10-1 100 101 102 Tj = 125C 140 120 100 80 60 40 20 0 -40 0 40 80 120 160 JUNCTION TEMPERATURE, Tj, (C) BREAKOVER VOLTAGE, (dv/dt = x V/ s) BREAKOVER VOLTAGE, (dv/dt = 1V/ s) RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s) BREAKOVER VOLTAGE, (RGK = rk ) BREAKOVER VOLTAGE, (RGK = 1k ) GATE TO CATHODE RESISTANCE, RGK ,(k ) P-15 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR04AM Lead-Mount, Phase Control SCR 0.4 Amperes/400-600 Volts REPETITIVE PEAK REVERSE VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL) REPETITIVE PEAK REVERSE VOLTAGE, (tC) x 100% REPETITIVE PEAK REVERSE VOLTAGE, (25C) GATE TRIGGER CURRENT VS. GATE CURRENT PULSE WIDTH (TYPICAL) TURN-OFF TIME VS. JUNCTION TEMPERATURE (TYPICAL) 160 GATE TRIGGER CURRENT, (tw) x 100% GATE TRIGGER CURRENT, (DC) 105 Tj = 25C RGK = 1k tw 102 VD = 100V, RL = 47 , RGK = 1k , Ta = 25C 140 120 100 80 60 40 20 0 -40 0 40 80 120 160 JUNCTION TEMPERATURE, Tj, (C) 104 TURN-OFF TIME, tq, ( s) 0.1 s 101 103 100 102 100 101 102 103 10-1 10-1 100 101 102 GATE CURRENT PULSE WIDTH, tw, ( s) JUNCTION TEMPERATURE, Tj, (C) TURN-ON TIME VS. GATE CURRENT (TYPICAL) 40 35 TURN-ON TIME, Tgt, ( s) 30 25 VD = 50V, VR = 50V, IT = 2A, RGK = 1k , Ta = 25C DISTRIBUTION 20 15 10 5 0 0 40 80 120 160 GATE CURRENT, IGT, (mA) TYPICAL EXAMPLE P-16 |
Price & Availability of CR04AM400-12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |