If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PA THE SLIM POWER RELAY PA-RELAYS FEATURES 20 .787 5 .197 12.5 .492 mm inch * Slim size (width 5 mm .197 inch, height 12.5 mm .492 inch) permits higher density mounting * Wide switching capacity: Control from 100A 100 mV to 5 A 250 V AC, 30 V DC * High sensitivity: 120 mW (Nominal) (5 to 18 V DC type) * High surge voltage (4000 V) and high breakdown voltage (2000 V) * Shock & vibration resistance (functional): Min. 147m/s2 {15 G} * SIL (single in line) terminal layout * Reinforced according to IEC1131-2 (TUV) SPECIFICATIONS Contacts (at 20C 68F) Characteristics Max. operating speed Initial insulation resistance*1 Initial break- Between open contacts down Between contacts and coil voltage*2 Surge voltage between contacts and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Temperature rise Shock resistance 120 mW 180 mW Functional*5 Destructive*6 Functional*7 Vibration resistance Destructive 20 cpm at rated load Min. 1,000 M at 500 V DC 1,000 Vrms 2,000 Vrms 4,000 V Approx. 6 ms Approx. 3 ms Max. 45C with nominal coil voltage across coil and at nominal switching capacity Min. 147 m/s2 {15 G} Min. 980 m/s2 {100 G} Min. 147 m/s2 {15 G}, 10 to 55 Hz at double amplitude of 2.5 mm Min. 205.8 m/s2 {21 G}, 10 to 55 Hz at double amplitude of 3.5 mm Arrangement 1a Contact material Gold-clad silver alloy Initial contact resistance, max. 30 m (By voltage drop 6 V DC 1 A) Nominal switching capacity 5 A 250 V AC, 5 A 30 V DC Maximum switching power 750 VA, 90 W Rating Maximum switching voltage 250 V AC, 110 V DC (resistive) Max. switching current 5A Min. switching capacity 100A, 100 mV DC 2x107 Expected life Mechanical (min. 3 A 250 V AC, 3 A 30 V DC, 105 operations) Electrical (at 20 cpm) 5 A 250 V AC, 5 A 30 V DC, 5x104 Coil (at 25C 77F, 50% R.H.) Nominal operating power Remarks * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10mA *3 Wave is standard shock voltage of 1.2x50s according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 11ms; detection time: 10s *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10s *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). 5 to 18 V DC 24 V DC Conditions for operation, Ambient temp. transport and storage*8 (Not freezing and condensHumidity ing at low temperature) Unit weight -40C to +70C -40F to +158F 5 to 85%R.H. Approx. 3 g .15 oz TYPICAL APPLICATIONS * Interface relays for programmable controllers * Output relays for measuring equipment, timers, counters and temperature controllers * Industrial equipment, office equipment ORDERING INFORMATION Ex. PA 1a 12V Coil voltage (DC) 5, 6, 9, 12, 18, 24V Contact arrangement 1a: 1 Form A Note: Standard packing: Tube: 25 pcs.; Case: 1,000 pcs. UL/CSA, TUV approved type is standard. TYPES AND COIL DATA Part No. PA1A-5VV PA1a-6VV PA1a-9VV PA1a-12V PA1a-18V PA1a-24V *1 Pulse driving (at 20C 68F) Drop-out voltage,* V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 Nominal operating current, mA (10%) 24 20 13.3 10 6.7 7.5 Nominal operating power, mW 120 120 120 120 120 180 Coil resistance, (10%) 208 300 675 1,200 2,700 3,200 Max. allowable voltage, V DC 6 7.2 10.8 14.4 21.6 28.8 Nominal voltage, V DC 5 6 9 12 18 24 Pick-up voltage,* V DC (max.) 3.5 4.2 6.3 8.4 12.6 16.8 214 PA DIMENSIONS 1. PA relay 1.3 .051 8.8 .346 0.5 .020 1.2 .047 12.5 2.9 (12.8 max.) .114 .492 (.504 max.) 3.5 .138 5 .197 2.54 .100 0.5 .020 10.16 .400 20 .787 5.08 .200 0.8 .031 1.11 .044 0.25 .010 1.18 .046 2.54 .100 1.0 dia. .039 dia. 1.0 dia. .039dia. 1.2 dia. .047 dia. 1.2 dia. .047 dia. mm inch PC board pattern (Copper-side view) 6 4.8 .237 .189 10.16 .400 5.08 .200 Tolerance: 0.1 .004 Schematic (Bottom view) General tolerance: 0.3 .012 N.O. COM Coil 2. Socket Standard type 5+0.2 -0.6 .197.008 -.024 Self clinching type 5+0.2 -0.6 .197.008 -.024 2.54 .100 90.6 .354.024 5.30.6 .209.024 0.25 .010 1.23 .048 10.25 .039.010 1.23 .048 3.9 .154 0.5 .020 2.54 .100 6.35 .250 0.8 .031 (0.3) (.012) 5.08 .200 2.54 .100 1.30.15 .051.006 PC board pattern (Copper-side view) 6 1 2 3 4 5 6 1 2 3 4 5 Standard type 10.16 .400 2-1 dia. 2-.039 dia. 5.08 .200 22.60.6 .890.024 22.60.6 .890.024 90.6 .354.024 5.30.6 .209.024 2-1.2 dia. 2-.047 dia. Self clinching type 10.16 .400 5.08 .200 PA1a-PS 4 .157 0.5 .020 2.54 .100 6.35 .250 0.8 .031 3.81 .150 (0.3) (.012) 5.08 .200 3.81 .150 2-0.80.25 dia. 2-.031002 dia. 2-1.20.05 dia. 2-.047002 dia. PA1a-PS PA1a-PS-H Tolerance: 0.1 .004 REFERENCE DATA 1. Max. switching capacity 2. Life curve 3.-(1) Coil temperature rise (120 mW) Sample: PA1a-12V Ambient temperature: 20C 68F Measured portion: Inside the coil 100 No. of operations, x104 90 Temperature rise, C 80 70 60 50 40 30 20 10 20 30 50 100 200 300 Contact voltage, V 0.5 1 2 3 5 10 Swiching capacity, A 100 0 100 110 120 130 140 150 Coil applied voltage, %V 5A 3A 2A 0A Contact current, A AC resistive load 5 4 3 2 1 0.5 0.4 0.3 0.2 DC resistive load 100 50 30 20 10 AC 125 V resistive load DC 30 V resistive load AC 250 V resistive load 3.-(2) Coil temperature rise (180 mW) Sample: PA1a-24V Ambient temperature: 20C 68F Measured portion: Inside the coil 100 4.-(1) Operate & release time (120 mW) Sample: PA1a-12V No. of samples: n = 20 4.-(2) Operate & release time (180 mW) Sample: PA1a-24V No. of samples: n = 20 10 Operate & release time, ms Operate & release time, ms 9 8 7 6 5 4 3 2 1 100 110 120 130 140 150 Coil applied voltage, %V 0 80 Release time Max. x Min. Max. x Min. 90 100 110 120 Coil applied voltage, %V Operate time 10 9 8 7 6 5 4 3 2 1 0 80 Release time Max. x Min. Max. x Min. Operate time 90 Temperature rise, C 80 70 60 50 40 30 20 10 0 5A 3A 2A 0A 90 100 110 120 Coil applied voltage, %V 215 PA 5. Ambient temperature characteristics Sample: PA1a-12V No. of samples: n = 6 40 Rate of change, % 30 20 10 Drop-out voltage -40 -20 0 -10 -20 -30 -40 20 50 75 980m/s2 Z' Pick-up voltage X Z 6. Malfunctional shock Sample: PA1a-12V No. of samples: n = 6 Z'Y' Y Y 980m/s2 80 60 40 20 20 40 60 80 100 Y' Deenergized condition Energized condition Z 980m/s2 X' X 980m/s2 Ambient temperature, C 980m/s2 X' NOTES 1. Specification values for pick-up and drop-out voltages are for the relay mounting with its terminals below. 100 90 80 70 Voltage, %V 60 50 40 30 20 10 0 Mounting direction Drop-out voltage Max. - x Min. Pick-up voltage Max. - x Min. 2. When mounting the relays within 1 mm. .039 inch , please notice the condition below. 1) Mount the relays in the same direction. Within 1 mm .039 inch 3) Allowable contact current is 2 A. 4) About the electrical life for close mounting, please refer to data below. 3.0 2.0 Contact current, A AC resistive load 1.0 DC resistive load 0.5 0.4 0.3 0.2 2) Coil terminals (Terminal No. 1 & 2) polarity should be arranged in the same direction. 20 30 50 100 Contact voltage, V 200 300 -. +. -. +. -. +. -. +. -. +. +. -. +. -. +. -. +. -. +. -. No. of operations, x104 100 50 40 30 20 AC 125V resistive load DC 30 V resistive load AC 250 V resistive load 10 0.5 1.0 2.0 3.0 Switching capacity, A For Cautions for Use, see Relay Technical Information (Page 48 to 76). 216 9/1/2000 All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd. Go To Online Catalog |
Price & Availability of PA1A-5V
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |