![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
PM150CSD120 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 IntellimodTM Module Three Phase IGBT Inverter Output 150 Amperes/1200 Volts A B AA - DIA. (4 TYP.) H Y AC W W W RY AC Y Z V 12 3 4 5678 9 11 13 15 17 19 T Q Q 10 12 14 16 18 AE (15 TYP.) F EC B J AB - THD (6 TYP.) 1. V UPC 2. UFO 3. U P 4. V UPI 5. V VPC 6. VFO 7. V P 8. V VPI 9. V WPC 10. WFO 11. W P 12. V WPI 13. V NC 14. V NI 15. NC 16. U N 17. V N 18. W N 19. FO P N W U V W AH AH Z G M D M S Z Z Y 2.54 MM DIA. (2 TYP.) 0.5 MM SQ. PIN (19 TYP.) AF AG X P AD U N L K Description: Powerex IntellimodTM Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to 20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel diode power devices. Features: Complete Output Power Circuit Gate Drive Circuit Protection Logic - Short Circuit - Over Current - Over Temperature - Under Voltage Low Loss Using 4th Generation IGBT Chip Applications: Inverters UPS Motion/Servo Control Power Supplies Ordering Information: Example: Select the complete part number from the table below -i.e. PM150CSD120 is a 1200V, 150 Ampere IntellimodTM Intelligent Power Module. Type PM Current Rating Amperes 150 VCES Volts (x 10) 120 V WPC WP W FO V WPI OUT VCC OUT VCC OUT VCC OUT VCC OUT VCC GND GND GND GND GND GND GND GND GND GND GND GND TEMP NC N W V U OUT VCC P FO FO FO FO FO SI SI SI SI SI Outline Drawing and Circuit Diagram Dimensions A B C D E F G H J K L M N P Q R Inches 5.310.04 4.740.02 4.330.04 4.27 3.760.02 3.29 2.01 1.602 1.54 1.37 1.33 1.02 Millimeters 135.01.0 120.50.5 110.01.0 108.5 95.50.5 83.5 51.0 40.68 39.0 34.7 33.7 26.0 Dimensions S T U V W X Y Z AA AB AC AD AE AF AG AH Inches 0.69 0.65 0.52 0.43 0.39 0.16 0.285 0.24 0.22 Dia. Metric M5 0.128 0.10 0.08 0.07 0.06 0.02 Millimeters 17.5 16.5 13.2 11.0 10.0 4.0 7.25 6.0 Dia. 5.5 M5 3.22 2.6 2.0 1.8 1.6 0.5 0.95 +0.06/-0.0 24.1 +1.5/-0.0 0.85 0.79 0.780 21.5 20.0 19.82 SI FO IN IN IN IN IN IN V UPC UP U FO V UPI V VPC VP V FO V VPI V NC WN FO NC VNI VN UN 1 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM150CSD120 IntellimodTM Module Three Phase IGBT Inverter Output 150 Amperes/1200 Volts Absolute Maximum Ratings, Tj = 25C unless otherwise specified Characteristics Power Device Junction Temperature Storage Temperature Case Operating Temperature* Mounting Torque, M5 Mounting Screws Mounting Torque, M5 Main Terminal Screws Module Weight (Typical) Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V, Inverter Part) Tj = 125C Isolation Voltage, AC 1 minute, 60Hz Sinusoidal Symbol Tj Tstg TC -- -- -- VCC(prot.) VISO PM150CSD120 -20 to 150 -40 to 125 -20 to 100 31 31 920 800 2500 Units C C C in-lb in-lb Grams Volts Volts IGBT Inverter Sector Collector-Emitter Voltage (VD = 15V, VCIN = 15V) Collector Current, (TC = 25C) Peak Collector Current, (TC = 25C) Supply Voltage (Applied between P - N) Supply Voltage, Surge (Applied between P - N) Collector Dissipation (TC = 25C) VCES IC ICP VCC VCC(surge) PC 1200 150 300 800 1000 781 Volts Amperes Amperes Volts Volts Watts Control Sector Supply Voltage Applied between (VUP1-VUPC, VVP1-VVPC, VWP1-VWPC, VN1-VNC) Input Voltage Applied between (UP-VUPC, VP-VVPC, WP-VWPC, UN- VN- WN-VNC) Fault Output Supply Voltage (Applied between UFO-VUPC, VFO-VVPC, WFO-VWPC, FO-VNC) Fault Output Current (UFO, VFO, WFO, FO) IFO 20 mA VD VCIN VFO 20 20 20 Volts Volts Volts Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector Cutoff Current ICES VEC VCE(sat) ton trr tC(on) toff tC(off) VD = 15V, VCIN = 0 ~ 15V VCC = 600V, IC = 150A Tj = 125C, Inductive Load VCE = VCES, Tj = 25C, VD = 15V, VCIN = 15V VCE = VCES, Tj = 125C, VD = 15V, VCIN = 15V Diode Forward Voltage Collector-Emitter Saturation Voltage Inductive Load Switching Times -IC = 150A, VD = 15V, VCIN = 15V VD = 15V, VCIN = 0V, IC = 150A, Pulsed, Tj = 25C VD = 15V, VCIN = 0V, IC = 150A, Pulsed, Tj = 125C -- -- -- -- -- 0.5 -- -- -- -- -- -- 2.5 2.4 2.1 1.0 0.15 0.4 2.5 0.7 1.0 10 3.5 3.2 2.8 2.5 0.3 1.0 3.5 1.2 mA mA Volts Volts Volts S S S S S *TC Measure Point 10 12 12 3 4 5678 9 11 14 16 18 13 15 17 19 P N B TC 63MM U V W 2 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM150CSD120 IntellimodTM Module Three Phase IGBT Inverter Output 150 Amperes/1200 Volts Electrical and Mechanical Characteristics, Tj = 25C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Control Sector Over Current Trip Level (VD = 15V) Short Circuit Trip Level Over Current Delay Time Over Temperature Protection (VD = 15V) (Lower Arm) Supply Circuit Under Voltage Protection (-20 Tj 125C) Circuit Current SC toff(OC) OT OTR UV UVR ID VCIN(on) VCIN(off) IFO(H) IFO(L) Minimum Fault Output Pulse Width* tFO OC Tj = 25C Tj = 125C -20C Tj 125C, VD = 15V VD = 15V Trip Level Reset Level Trip Level Reset Level VD = 15V, VCIN = 15V, VN1-VNC VD = 15V, VCIN = 15V, VXP1-VXPC Input ON Threshold Voltage Input OFF Threshold Voltage Fault Output Current* Applied between UP-VUPC, VP-VVPC, WP-VWPC, UN, VN, WN-VNC VD = 15V, VCIN = 15V VD = 15V, VCIN = 15V VD = 15V 282 200 -- -- 111 -- 11.5 -- -- -- 1.2 1.7 -- -- 1.0 410 -- 540 10 118 100 12.0 12.5 45 15 1.5 2.0 -- 10 1.8 -- -- -- -- 125 -- 12.5 -- 62 20 1.8 2.3 0.01 15 -- Amperes Amperes Amperes S C C Volts Volts mA mA Volts Volts mA mA mS *Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower devide operate to protect it. Thermal Characteristics Characteristic Junction to Case Thermal Resistance Symbol Rth(j-c)Q Rth(j-c)F Rth(j-c)Q Rth(j-c)F Contact Thermal Resistance Rth(c-f) Condition Each IGBT Each FWDi Each IGBT** Each FWDi** Case to Fin Per Module, Thermal Grease Applied ** TC measured point is just under chip. If you use this value, Rth(f-a) should be measured just under the chips. Min. -- -- -- -- -- Typ. -- -- -- -- -- Max. 0.16 0.24 0.10 0.16 0.018 Units C/Watt C/Watt C/Watt C/Watt C/Watt Recommended Conditions for Use Characteristic Supply Voltage Control Supply Voltage*** Symbol VCC VD VCIN(on) VCIN(off) fPWM tDEAD Condition Applied across P-N Terminals Applied between VUP1-VUPC, VN1-VNC, VVP1-VVPC, VWP1-VWPC Input ON Voltage Input OFF Voltage PWM Input Frequency Minimum Dead Time Applied between UP-VUPC, VP-VVPC, WP-VWPC, UN, VN, WN-VNC Using Application Circuit Input Signal 0 ~ 0.8 4.0 ~ VD 0 ~ 20 3.0 Volts Volts kHz S Value 0 ~ 800 15 1.5 Units Volts Volts *** With ripple satisfying the following conditions: dv/dt swing 5V/s, Variation 2V peak to peak. 3 Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 PM150CSD120 IntellimodTM Module Three Phase IGBT Inverter Output 150 Amperes/1200 Volts SATURATION VOLTAGE CHARACTERISTICS (TYPICAL) DIODE FORWARD CHARACTERISTICS (TYPICAL) SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) 3.0 SATURATION VOLTAGE, VCE(sat), (VOLTS) 103 VD = 15V VCIN = 0V Tj = 25oC Tj = 125oC VD = 15V Tj = 25oC Tj = 125oC 101 DIODE CURRENT, -IC, (AMPERES) 2.5 2.0 1.5 1.0 0.5 0 0 SWITCHING TIMES, ton, toff, (s) toff 102 100 ton 101 40 80 120 160 200 0 0.5 1.0 1.5 2.0 2.5 COLLECTOR CURRENT, IC, (AMPERES) DIODE FORWARD VOLTAGE, VEC, (VOLTS) VCC = 600V VD = 15V Tj = 25oC Tj = 125oC INDUCTIVE LOAD 10-1 101 102 COLLECTOR CURRENT, IC, (AMPERES) 103 SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL) REVERSE RECOVERY CURRENT VS. COLLECTOR CURRENT (TYPICAL) SWITCHING LOSS CHARACTERISTICS (TYPICAL) 101 REVERSE RECOVERY TIME, trr, (S) 100 VCC = 600V VD = 15V Tj = 25oC Tj = 125oC INDUCTIVE LOAD 103 REVERSE RECOVERY CURRENT, Irr, (AMPERES) SWITCHING LOSS, ESW, (m)J/PULSE) 102 SWITCHING TIMES, tc(on), tc(off), (s) Esw(off) 101 Esw(on) Esw(off) trr 100 tc(off) tc(off) 10-1 Irr 102 tc(on) VCC = 600V VD = 15V Tj = 25oC Tj = 125oC INDUCTIVE LOAD 100 VCC = 600V VD = 15V Tj = 25oC Tj = 125oC INDUCTIVE LOAD 10-1 101 102 COLLECTOR CURRENT, IC, (AMPERES) 103 10-2 101 102 COLLECTOR CURRENT, -IC, (AMPERES) 101 103 10-1 101 102 COLLECTOR CURRENT, IC, (AMPERES) 103 TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (IGBT & FWDi - INVERTER PART) TRANSIENT IMPEDANCE, Zth(j-c), (NORMALIZED VALUE) CIRCUIT CURRENT VS. CARRIER FREQUENCY 101 120 Tj = 25oC 100 CIRCUIT CURRENT, ID, (mA) N-SIDE 100 80 60 40 P-SIDE 10-1 10-2 STANDARD VALUE Rth(j-c)Q = 0.16oC/W (IGBT) Rth(j-c)F = 0.24oC/W (FWDi) SINGLE PULSE 20 0 10-3 10-3 10-2 10-1 TIME, (s) 100 101 0 5 10 15 20 25 CARRIER FREQUENCY, fC, (kHz) 4 |
Price & Availability of PM150CSD12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |