 PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
PM7346
S/UNI-QJET
SATURN USER NETWORK INTERFACE (QJET)
ERRATA
ISSUE1 JUNE 1999
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
REVISION HISTORY Issue No. 1 Issue Date Details of Change
June 1999
This document contains errata information corresponding to the issue 5 datasheet.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
CONTENTS
1
ISSUE 1 ERRATA ..................................................................................... 1 1.1 DEVICE IDENTIFICATION............................................................. 1
2
SOFTWARE RESET REQUIRED AFTER POWER UP............................ 2
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
i
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
1
ISSUE 1 ERRATA This issue 1 contains errata applied to the PMC-960835 S/UNI-QJET Issue 5 datasheet. The issue 5 datasheet and issue 1 errata supersede all prior editions and versions.
1.1
Device Identification The information contains in this document applies to the PM7346 S/UNI-QJET revision E. The device revision code is marked at the end of the Wafer Batch Code on the face of the device (as shown in Figure 1). PM7346 S/UNI-QJET revision E is packaged in a 256 pin Super BGA package. Figure 1: PM7346 S/UNI-QJET Branding Format
Pin A1 Index Mark
PMC Logo
S/UNI-QJET Logo
TM
S /UNI-QJET
PM7346-BI C E Myyww
TOP VIEW SCALE : 2:1 (APPROX.)
Part Number Wafer Batch Code Assembly Date Code
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
1
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
2
SOFTWARE RESET REQUIRED AFTER POWER UP After hardware reset the S/UNI-QJET needs a software reset to reduce power consumption. This problem has no implications to the functionality of the part except for excessive power consumption and resulting excess heat dissipation. Software initialization sequence: A modification to the software initialization sequence used will guarantee that the S/UNI QJET operates with normal power consumption. The sequence below will set the all the RAM in the QJET to a low power state. 1. Reset the S/UNI QJET. 2. Set IOTST (bit 2) in the Master Test Register (datasheet pg. 291) to '1' (by writing 00000100 to register 400H). 3. Put the QJET Receive Cell Processor (RXCP) into test mode by writing: 00000101 to test register 461H 00000101 to test register 561H 00000101 to test register 661H 00000101 to test register 761H 4. Set QJET Receive Cell Processor block built in self-test (BIST) controls signals by writing: 01000000 to test register 462H 01000000 to test register 562H 01000000 to test register 662H 01000000 to test register 762H 10101010 to test register 463H 10101010 to test register 563H 10101010 to test register 663H 10101010 to test register 763H 5. Put the QJET Transmit Cell Processor (TXCP) into test mode by writing: 00000011 to test register 481H 00000011 to test register 581H 00000011 to test register 681H 00000011 to test register 781H 6. Set QJET Transmit Cell Processor block built in self-test (BIST) controls signals by writing: 10000000 to test register 480H 10000000 to test register 580H 10000000 to test register 680H
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
10000000 to test register 780H 10101010 to test register 482H 10101010 to test register 582H 10101010 to test register 682H 10101010 to test register 782H 7. Toggle REF8KI (pin T3, datasheet page 29) signal several times (this provides the clock to the RAM). REF8KI is the test clock used by the TXCP and RXCP blocks when in test mode. 8. Set IOTST (bit 2) in the Master Test register (datasheet pg. 291) to '0' (by writing 00000000 to register 400H). This sequence will correct the excess power consumption of the internal RAM. Performance without software sequence: Failure to run this sequence will result in excess power consumption and a degraded long term reliability. Therefore, it is critical that the above software fix be implemented.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
NOTES
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
4
PRELIMINARY ERRATA PMC-990537 ISSUE 1
PM7346 S/UNI-QJET
S/UNI-QJET DATASHEET ERRATA
CONTACTING PMC-SIERRA, INC. PMC-Sierra, Inc. 105-8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: Fax: (604) 415-6000 (604) 415-6200
Document Information: document@pmc-sierra.com Corporate Information: info@pmc-sierra.com Application Information: apps@pmc-sierra.com (604) 415-4533 Web Site: http://www.pmc-sierra.com
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 1999 PMC-Sierra, Inc. PMC-990537 (R1) ref PMC 960835 (R5) Issue date: June 1999
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE


▲Up To Search▲   

 
Price & Availability of 1990537

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X