Part Number Hot Search : 
MX29L S1X70000 K3020 UPD70 CPC5610 01524 DDA122TU 5532K
Product Description
Full Text Search
 

To Download 1140-G111-P1M1-10A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Thermal Overcurrent Circuit Breaker 1140-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset tease-free, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Available in versions for panel mounting, snap-in or threadneck, or as an integral type. For lower current ratings see types 104, 105, 106. Approved to CBE standard EN 60934 (IEC 60934).
1
Typical applications
Motors, transformers, solenoids, hand-held machines and appliances.
1140-E... Ordering information
Type No. 1140 single pole thermal circuit breaker Mounting E2 integral mounting F1 snap-in panel mounting G1 threadneck panel mounting 3/8-27UNS with hex nut and knurled nut * G2 threadneck panel mounting 3/8-27UNS for standard fuseholder cut-out* with plastic knurled nut Number of poles 1 1 pole protected Actuator style 1 black push button (standard) Terminal design P1 blade terminals A6.3-0.8 (QC .250) Characteristic curve M1 medium delay Current ratings 3.5...16 A 1140 - F1 1 1 - P1 M1 - 10 A *mounting hardware bulk shipped Packaging quantity: 125 pcs ordering example
1140-F...
1140-G.1.
Technical data
Voltage rating Current ratings Typical life Ambient temperature Insulation co-ordination (IEC 60664 and 60664A) AC 240 V; DC 48 V (AC 250 V; DC 50 V UL/CSA) 3.5...16 A 3.5...8 A 1000 operations at 2 x IN 10...16 A 50 operations at 2 x IN -20...+60 C (-4...+140 F) T 60 Rated impulse Pollution withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Test voltage AC 3,000 V > 100 M (DC 500 V) 3.5... 8 A 8 x IN 10...16 A 120 A IN 3.5...16 A 3.5 ... 7A 8 ...16 A UN DC 50 V AC 250 V AC 250 V 200 A 1,000 A 2,000 A
Dielectric strength (IEC 60664 and 60664A) operating area Insulation resistance Interrupting capacity Icn Interrupting capacity (UL 1077)
Degree of protection (IEC 60529/DIN 40 050) Vibration
operating area IP 40 terminal area IP 00 10 g (57-500 Hz) 0.76 mm (10-57 Hz), to IEC 60068-2-6, Test Fc, 10 frequency cycles/axis 25 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 10 g
Standard current ratings and typical internal resistance values Shock
Current rating (A) 3.5 4 5 6 7 8 Internal resistance () 0.06 0.04 0.03 0.02 < 0.02 < 0.02 Current rating (A) 10 12 13 15 16 Internal resistance () < 0.02 < 0.02 < 0.02 < 0.02 < 0.02
Corrosion Humidity Mass
Approvals
Authority VDE UL / CSA Semko Kema (EN 60934) Voltage ratings AC 240 V; DC 28 V AC 250 V; DC 50 V AC 240 V AC 240 V; DC 48 V Current ratings 7 ...16 A 3.5...16 A 7 ...16 A 3.5...16 A
All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.
Issue C
USA (847) 827-7600 - CANADA (905) 764-9510
45
Thermal Overcurrent Circuit Breaker 1140-...
Dimensions
1140-E211-P1M1
11 OFF .433 ON 7.8 .307
o4.2 .165 o7 .276
Internal connection diagram
1
Accessory
Water splash cover/knurled nut assembly, transparent X 201 285 01 (IP 64)
27.5 1.08
1
4 .157
34.5 1.36
2
Typical time/current characteristics at +23C/+73.4F
19 .748 blade terminal DIN 46244-A6.3-0.8 (QC .250)
10000
9 .354
11 .433
1000
Trip time in seconds
hole for mounting screw M2x5
100
1140-F111-P1M1
11 OFF .433 ON 7.8 .307 4 .157
o4.2 .165 o7 .276
10
2 .079
1
27.5 1.08
34.5 1.36
0.1
1 2
9 .354
19 .748 25 .984
blade terminal DIN 46244-A6.3-0.8 (QC .250) panel cut-out
11 .433
4 6 8 10 20 ... times rated current
40
11.3 +0.3
.445 +.012
The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 - Technical information. Ambient temperature F C Multiplication factor -4 +14 +32 +73.4 +104 +122 +140 -20 -10 0 +23 +40 +50 +60 0.76 0.84 0.92 1 1.08 1.16 1.24
1140-G111-P1M1
8 .315
OFF
o4.2 .165
d
a
mm 0.8 1.0 1.5 2-3
a inch mm inch .031 21.9 .862 .039 22 .866 .059 22.1 .870 .079-.118 22.2 .874
d
14 .551
Installation drawings
1140-F...
operating area
14 .551 10.8 .425
ON
7 .276
8 .315
mounting area
0.7 .028 27.5 1.08
34.5 1.36
1140-E...
8 .315
operating area
blade terminal DIN 46244-A6.3-0.8 (QC .250) mounting hole SW 14 .551
8 .315
mounting area
1140-G...
operating area
11 .433
9 .354 19 .748
.378 -.004
o9.6 -0.1
8.9 -0.1 .350 -.004
8 .315
8 .315
mounting area
8 .315
8 .315
mm
This is a metric design and millimeter dimensions take precedence ( inch )
46
USA (847) 827-7600 - CANADA (905) 764-9510
8 .315
8 .315
8 .315
8 .315
tightening torque max. 1 Nm 3/8-27 UNS-2A
Issue C
Thermal Overcurrent Circuit Breaker 1140-... (2 pole)
Description
Miniaturised double pole thermal circuit breaker with push-to-reset teasefree, trip-free, snap action mechanism (R-type TO CBE to EN 60934). Threadneck panel mounting. Suitable for line and neutral switching - the thermal actuator operating on one pole simultaneously opens both poles under overload conditions. Approved to CBE standard EN 60934 (IEC 60934).
1
Typical applications
Motors, transformers, solenoids, hand-held machines and appliances. Especially suited to AC duties where the correct orientation of line/ neutral is not known/cannot be guaranteed.
1140-G.5. Technical data
Voltage rating Current ratings Typical life AC 240 V; DC 48 V (AC250 V; DC 50 V UL/CSA) 0.05...16 A 0.05...3 A 3,000 operations at 2 x IN 3.5... 8 A 1,000 operations at 2 x IN 10... 16 A 50 operations at 2 x IN -20...+60 C (-4...+140 F) T 60 Rated impulse Pollution withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Test voltage AC 3,000 V AC 1,500 V > 100 M (DC 500 V) 0.05...3 A 3.5... 8 A 10... 16 A IN 0.05...16 A 0.05...7 A 8...16 A 6 x IN 8 x IN 120 A UN DC 50 V AC 250 V AC 250 V 200 A 1,000 A 2,000 A
Ordering information
Type No. 1140 double pole threadneck panel mounting Mounting G1 threadneck panel mounting 3/8-27UNS, with hex nut and knurled nut * G2 threadneck panel mounting 3/8-27UNS, with plastic knurled nut* Number of poles 5 double pole, 1 pole protected Actuator style 1 black push button (standard) Terminal design P7 blade terminals DIN 46244-C (QC 2x.110) Characteristic curve M1 medium delay Current ratings 0.05...16 A 1140 - G1 5 1 - P7 M1 - 16 A *mounting hardware bulk shipped Packaging quantity: 125 pcs ordering example
Ambient temperature Insulation co-ordination (IEC 60664 and 60664A)
Dielectric strength (IEC 60664 and 60664A) operating area pole/pole Insulation resistance Interrupting capacity Icn
Interrupting capacity (UL 1077) Standard current ratings and typical internal resistance values
Current rating (A) 0.05 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1 1.2 1.5 Internal resistance () 345 240 142 88 24 9.9 5.9 3.7 2.2 1.9 1.4 0.9 0.6 0.5 Current rating (A) 1.8 2 2.5 3 3.5 4 5 6 7 8 10 12 15 16 Internal resistance () 0.3 0.3 0.2 0.1 0.06 0.04 0.03 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 Authority
All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted.
Degree of protection (IEC 60529/DIN 40050) Vibration
operating area IP 40 terminal area IP 00 10 g (57-500 Hz) 0.76 mm (10-57 Hz), to IEC 60068-2-6, Test Fc, 10 frequency cycles/axis 25 g (11 ms) to IEC 60068-2-27, test Ea 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-3, test Ca approx. 13 g
Shock Corrosion Humidity Mass
Approvals
Voltage ratings AC 240 V; DC 28 V AC 250 V; DC 50 V AC 240 V; DC 48 V Current ratings 0.05...16 A 0.05...16 A 0.05...16 A
VDE UL, CSA Kema (EN 60934)
Issue C
USA (847) 827-7600 - CANADA (905) 764-9510
47
Thermal Overcurrent Circuit Breaker 1140-... (2 pole)
Dimensions
1140-G15...
ON
Internal connection diagram
tightening moment max. 1 Nm 3/8-27 UNS-2A
OFF
o4.2 .165
1
3
14 .551 10.8 .425
0.7 .028
1
7 .276
4
49.5 1.95
2
blade terminal DIN 46244-A6.3-0.8 (QC .110) SW 14 .551
11 .433
mounting hole
Typical time/current characteristics at +23C/+73.4F
10000
0.05 - 3 A 3.5 - 16 A
9 .354 19 .748
.378 -.004
o9.6
8.9 -0.1 .350 -.004
1000
1140-G25...
tightening moment max. 1 Nm 3/8-27 UNS-2A
ON
o4.2 .165
Trip time in seconds
OFF
100
14 .551 10.8 .425
7 .276
10
0.7 .028 49.5 1.95
1
13.8 +0.15 -0.1
mounting holes
.543 +.006 - .004
blade terminal DIN 46244-A6.3-0.8 (QC .110)
0.1 1 2 4 6 8 10 ... times rated current 20 40
11 .433
9 .354 19 .748
o9.6 .378 -.004
8.9 -0.1 .350 -.004
The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section 9 - Technical information. Ambient temperature F C Multiplication factor -4 +14 +32 +73.4 +104 +122 +140 -20 -10 0 +23 +40 +50 +60 0.76 0.84 0.92 1 1.08 1.16 1.24
o160.1 .630.004 panel thickness >0.8 mm (.031in.)
Installation drawing
Accessories
Water splash cover/knurled nut assembly, transparent X 201 285 01 (IP 64)
operating area
8 .315
mounting area
8 .315
This is a metric design and millimeter dimensions take precedence ( inch )
mm
48
USA (847) 827-7600 - CANADA (905) 764-9510
Issue C


▲Up To Search▲   

 
Price & Availability of 1140-G111-P1M1-10A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X