 SCC SERIES
Pressure Sensors
FEATURES
* 0 - 5 to 0 - 300 psi * Low Cost Sensor Element * Internal Temperature Compensation * Differential, Gage and Absolute
GENERAL DESCRIPTION
The SCC series offer an extremely low cost sensor element with a temperature stable output when driven with a constant current source. These integrated circuit sen-sors were designed for extremely cost sensitive applications where precise accuracy over a wide temperature range is not required. This series is intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Absolute devices have an internal vacuum reference and an output voltage proportional to applied pressure. The differential devices allow application of pressure to either side of the diaphragm and the devices are thereby available to measure both differential and/or gage pressures. This product is packaged either in SenSyms standard low cost chip carrier "button" package, a plastic ported "N" package, a metal package or a dual inline package (DIP). All packages are designed for applications where the sensing element is to be integral to the OEM equipment. These packages can be O-ring sealed, epoxied, and/or clamped onto a pressure fitting. A closed bridge four-pin SIP configuration is
APPLICATIONS
* Pneumatic Controls * Automotive Diagnostics * Medical Equipment * Dental Equipment * Environmental Controls
Scale:
1cm 1/2 inch
provided for electrical connection to the button package. The TO can and the DIP offer a 5-pin open bridge configuration.
EQUIVALENT CIRCUIT
Vs
ELECTRICAL CONNECTIONS
GND 1 out + 2 +VS 3 out - 4
+
Output
SCC.. Button Sensor
+Vs 1 out + GND +Vs 4 out vent hole
TO Can (buttom view)
1 +Vs
out + GND 1 P1 P2 4 +Vs +Vs
Button Sensor or "N" Package
out GND out +
4
+Vs
out -
Vs
SCCxxxGD2 DIP
SCCxxxAD2 DIP SCCxxxD4 DIP
Output
The polarity indicated is for pressure applied to SCC.../SCC...N : P1 (forward gage) SCC...ASO/GSO : P1 (forward gage) SCC...DD4 : P2 (backward gage)
SCC...GD2 SCC...AD2
: :
P2 P1
(backward gage) (forward gage)
+
(Open Bridge) TO Can or DIP Package
January 1998/040
Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com
SCC SERIES
Pressure Sensors
PRESSURE SENSOR CHARACTERISTICS
Maximum Ratings (For All Devices)
Supply Current, IS Temperature Ranges Compensated Operating Storage Humidity Lead Temperature (soldering 4 sec) Common-Mode Pressure 1.5 mA 0C to +50C -40C to +85C -55C to +125C 0 to 100 %RH 250C 150 psi
Performance Characteristics (Individual Models) IS = 1.0 mA, TA = 25C1
Part Number
SCC05(D,G) SCC15A SCC15(D,G) SCC30(A,D,G) SCC100A SCC100(D,G)9 SCC300A
Operating Pressure Range
0-5 psid(g) 0-15 psia 0-15 psid(g) 0-30 psid(g) 0-100 psia 0-100 psig 0-300 psia
Maximum Over Pressure
20 psi 30 psia 30 psi 60 psi 150 psia 150 psig 450 psia
Accuracy2
0.50% 0.50% 0.50% 0.50% 0.50% 0.50% 0.50%
Effect On Span3 (0C-50C)
1.50% 1.50% 1.50% 1.50% 1.50% 1.50% 1.50%
Effect On Offset4 (0C-50C)
2.00% 2.00% 2.00% 2.00% 2.00% 2.00% 2.00%
Full-Scale Span5 (mV)
25-65 30-95 40-95 60-150 85-225 85-225 50-120
Performance Characteristics (All Models) IS = 1.0 mA, TA = 25C
Characteristics
Zero Pressure Offset Combined, Linearity, Hysteresis, Repeatability2 Temperature Effect on Span3, 8 Temperature Effect on Offset4,8 Long Term Stability of Offset and Span6 Response Time (10% to 90%)7 Input Impedance Output Impedance
Min.
-30.0 ----------4.00 4.00
Typ.
-10 0.25 0.25 0.50 0.10 0.10 5.00 5.00
Max.
20.0 0.50 1.50 2.00 ----6.50 6.50
Unit
mV %FSO %FSO %FSO %FSO mSec k k
Specification Notes:
1: 2: 3: 4: 5: 6: Reference Conditions: Supply Current = 1.0 mA, TA=25C, Common-mode Line Pressure = 0 psig, Pressure Applied to P1, unless otherwise noted. Accuracy is the sum of Hysterisis and Linearity. Hysterisis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and 1/2 full-scale pressure at 25C. This is the maximum temperature shift for span when measured between 0C and 50C relative to the 25C reading. Typical temperature coefficients for span and resistance are -2200 ppm/C and +2200 ppm/C respectively. This is the maximum temperature shift for offset when measured between 0C and 50C relative to the 25C reading. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Maximum difference in output at any pressure with the operating pressure range and temperature within 0C to 50C after: a) 100 temperature cycles, 0C to 50C b) 1.0 million pressure cycles, 0 psi to full-scale span Response time for a 0 psi to full-scale span pressure step change. 10% to 90% rise time Temp effect on span and offset are guaranteed by design. Therefore these parameters are not 100% tested. The SCC100D devices can only be used in a forward gauge mode. Application of more than 30 psig to the back side of any of the SCC Series devices can result in device failure.
7: 8: 9:
January 1998/040
Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com
SCC SERIES
Pressure Sensors
PHYSICAL DIMENSIONS
Button Package
Basic Sensor DIP "D2" Package
January 1998/040
Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com
SCC SERIES
Pressure Sensors
PHYSICAL DIMENSIONS (cont.)
Basic Sensor DIP "D4" Package
N Package
January 1998/040
Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com
SCC SERIES
Pressure Sensors
PHYSICAL DIMENSIONS (cont.)
AHO Package (TO-5)
GSO Package (TO-39)
ORDERING INFORMATION
Pressure Range
Absolute Pressure 0 - 15 psi 0 - 30 psi 0 - 100 psi 0 - 300 psi Gage Pressure 0 - 5 psi 0 - 15 psi 0 - 30 psi 0 - 100 psi Differential Pressure 0 - 5 psi 0 - 15 psi 0 - 30 psi 0 - 100 psi(9)
Button Package
"N" Package
Order Part Number TO Package DIP Package single port
SCC15AHO SCC30AHO SCC100AHO SCC300AHO SCC05GSO SCC15GSO SCC30GSO ----------SCC15AD2 SCC30AD2 SCC100AD2
DIP Package Dual port
----------------SCC05DD4 SCC15DD4 SCC30DD4 SCC100DD4
SCC15A SCC30A SCC100A --use differential devices
SCC15AN SCC30AN SCC100AN --use differential devices
SCC05GD2 SCC15GD2 SCC30GD2 -----------
SCC05D SCC15D SCC30D SCC100D
SCC05DN SCC15DN SCC30DN SCC100DN
SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
January 1998/040
Aubinger Weg 27, 82178 Puchheim, Germany Phone 0049 - (0) 89 80 08 30, Fax 0049 - (0) 89 8 00 83 33 http://www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of SCC100AD2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X