Part Number Hot Search : 
IRGPC 2302M NTHD4502 25C256 IRF351 2N6395G AATIAN26 EPR1010
Product Description
Full Text Search
 

To Download 1990107 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
PM5350
S/UNI-155 ULTRA
SATURN USER NETWORK INTERFACE
DATASHEET ERRATA ISSUE 4: FEBRUARY 2002
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
1
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
REVISION HISTORY Issue No. 4 3 2 1 Issue Date Details of Change
February 2002 May 2000 Jun 1999 Jan 1999
Added Canadian patent number (Prep 6584) Added U.S., Canadian, UK and French patent numbers (Prep 7005) Capacitor needed between RCAP1 and RCAP2 for UTP-5 mode to function. Specification of power supply ramp in low temperature conditions. This document contains changes to the datasheet revision 5 and details changes for industrial temperature optical operation
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
CONTENTS 1 2 ISSUE 4 ERRATA ..........................................................................................2 INDUSTRIAL TEMPERATURE OPERATION .......................................................3 2.1 2.2 3 4 5 PAGE 183 .........................................................................................3 PAGES 197-199 .................................................................................3
ANALOG POWER-UP RAMP RATE REQUIREMENT AT LOW TEMPERATURE.........6 CAPACITOR NEEDED BETWEEN RCAP1 AND RCAP2 FOR UTP-5 MODE .............8 PATENT INFORMATION ...............................................................................10
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
1
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
1
ISSUE 4 ERRATA This issue 4 errata notifies that changes have been made to the issue 5 of the PMC-960924 data sheet. A summary of the changes made to the issue 5 datasheet is provided. The issue 5 datasheet and issue 4 errata supersede all prior editions and versions.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
2
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
2
INDUSTRIAL TEMPERATURE OPERATION The device has been re-qualified for operation in industrial temperature conditions under certain circumstances. Specifically, if the device is operated in PECL mode only (i.e. with PECLSEL selected TTL high) the device can be used in industrial temperature conditions (i.e. -40 to 85 degrees Celsius). However, if the device is used in UTP-5 applications (i.e. with PECLSEL selected TTL low) the device is only rated for commercial temperature operation (i.e. 0 to 70 degrees Celsius). If the device is used in PECL mode under industrial temperature conditions certain timing parameters will be changed. However, the device can be used in PECL mode under commercial temperatures without modifying the timing.
2.1
Page 183 Page 183 section 10 "Absolute maximums" has been changed to the following:
Ambient Temperature under Bias (UTP-5) Ambient Temperature under Bias (PECL) Storage Temperature Supply Voltage Voltage on Any Pin Static Discharge Voltage Latch-Up Current DC Input Current Lead Temperature Junction Temperature
0C to +70C -40C to +85C -40C to +125C -0.5V to +6.0V -0.5V to VDD+0.5V 1000 V 100 mA 20 mA +300C +150C
2.2
Pages 197-199 Pages 197-199 Tables 6 and 7 of the issue 5 datasheet has changed to the following:
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
3
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
Table 6 - Drop Side Receive Synchronous Interface (TSEN = 0) (Figure 28) Symbol Description RFCLK Frequency RFCLK Duty Cycle tSRRDENB tHRRDENB tPRDAT tPRXP tPRCA tPRSOC RRDENB to RFCLK High Setup RFCLK High to RRDENB Hold RFCLK High to RDAT[7:0] Valid RFCLK High to RXPRTY Valid RFCLK High to RCA Valid RFCLK High to RSOC Valid 40 4 1 2* 2* 2 2 14 14 14 14 Min Max 50 60 Units MHz % ns ns ns ns ns ns
* NOTE: For PECL mode (i.e. not for UTP-5, PECLSEL pin driven TTL high) under industrial temperature, -40C to 85C operation (instead of 0C to 70C operation), the following timing parameters change: tPRDAT is 1.5ns for MIN. instead of 2ns tPRXP is 1.5 ns. for MIN. instead of 2ns Note PECL operation under 0C to 70C conditions can use the original values in Table 6.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
4
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
Table 7 - Drop Side Receive Synchronous Interface (TSEN = 1) (Figure 29) Symbol Description RFCLK Frequency RFCLK Duty Cycle tSRRDENB tHRRDENB tPRDAT tZRDAT tPRXP tZRXP tPRCA tPRSOC tZRSOC RRDENB to RFCLK High Setup RFCLK High to RRDENB Hold RFCLK High to RDAT[7:0] Valid RFCLK High to RDAT[7:0] Tristate RFCLK High to RXPRTY Valid RFCLK High to RXPRTY Tristate RFCLK High to RCA Valid RFCLK High to RSOC Valid RFCLK High to RSOC Tristate 40 4 1 2 2 2 2* 2 2 2 14 14 14 14 14 14 14 Min Max 50 60 Units MHz % ns ns ns ns ns ns ns ns ns
* NOTE: For PECL mode (i.e. not for UTP-5, PECLSEL pin driven TTL high) under industrial temperature, -40C to 85C operation (instead of 0C to 70C operation), the following timing parameters change: tZRXP is 1ns. for MIN. instead of 2ns Note PECL operation under 0C to 70C conditions can use the original values in Table 7.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
5
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
3
ANALOG POWER-UP RAMP RATE REQUIREMENT AT LOW TEMPERATURE Description The analog supply voltage (RAVD2) requires a minimum voltage ramp rate during up power up. If the power ramp is too slow the S/UNI ULTRA will be unable to lock to received data. The required ramp rate is a strong function of temperature, as shown in Table 1. Table 1 Maximum RAVD2 Power-up Ramp Time vs. Temperature Tambient (C) 25 0 -40 Maximum Ramp Time Requirement (10% to 90% voltage ramp) 50ms 1ms 1ms
Devices that are not powered up correctly will recover normal operation when the ambient temperature rises. Once operating normally, a device will continue to operate normally over the full rated temperature range. Recommendation Some board-level power supplies cannot provide the required voltage ramp rates for proper operation at 0C or -40C, so an external circuit is needed to gate the power to RAVD2. A recommended circuit is given below.
VCC 2.7ohm Si2301DS 36
PM5350 S/UNI-ULTRA
RAVD2
68uF
0.1uF
RESET (active high) Resistor, capacitors are part of existing supply filtering recommendations in reference design.
The RESET signal is a standard CMOS signal: 0 to 5V swing with trise and tfall <20ns. During device power-up, RESET must be held active (high) for at least 10ms to allow the capacitors to discharge. Then, when RESET is brought low, the device will begin operating normally.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE 6
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
Please contact the PMC-Sierra Applications department for more information. Performance with Recommendation All devices will power-up correctly over the entire industrial temperature range (-40 to 80C). Performance without Recommendation Upon power-up at low temperature, some devices may not lock to reference clock (RROOLV=1 in register 08h) and to data (RDOOLV=1 in register 80h). In this condition, the reference clock output (RCLK, pin 55) may be DC or very low frequency.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
7
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
4
CAPACITOR NEEDED BETWEEN RCAP1 AND RCAP2 FOR UTP-5 MODE
Page 22 RCAP1 RCAP2 Analog 27 28 The RCAP1 and RCAP2 pins should be connected to the RAVS3 analog ground. A non-polarized 0.1 uF capacitor must be connected between RCAP1 and RCAP2 for UTP-5 mode. A proper capacitor CRX must be used to provide proper frequency response for the Twisted-pair baseline wander correction circuit. These inputs can be tied to RAVS3 analog ground for PECL mode operation. Please refer to the APPLICATIONS and the EXTERNAL COMPONENTS sections of this document for a detailed CRX specification.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
8
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
Figure 17 has been updated with the following diagram: Figure 17 Interfacing TXD+/- and RXD+/- with UTP-5
PM5350 S/UNI-ULTRA
RCAP1 0.1uF RCAP2 SD RXD+ 100 W RXD- +5V TXD+ 50 W TXD- 50 W
8 7 5 4 6 3 2 1
Note 1
UTP-5 Transforme r module
Note 2
50W
50 W 50 W 50 W 50 W
75W 75W 50W
Receive
UTP-5 Facility
RJ-45
Transmit
TRREF RREF
Note 1: This is one of the available options for common mode termination. Note 2: Examples of appropriate transformer modules include: BELFUSE PN# A558-5999-00 PULSE ENGINEERING PN# PE68517 Please see schematics for transformer pin-out details.
TVR EF
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
9
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
5
PATENT INFORMATION
No patent information in original data sheet. Note: The technology discussed is protected by one or more of the following Patents: U.S. Patent No. 6,188,692 U.S. Patent No. 6,104,277 U.S. Patent No. 5,987,065 U.S. Patent No. 6,054,884 Canadian Patent No. 2,217,985 Canadian Patent No. 2,227,097 Canadian Patent No. 2,149,076 Canadian Patent No. 2,179,246 UK Patent No. 2,305,541 UK Patent No. 2,290,438 French Patent No. 2,738,953 Relevant patent applications and other patents may also exist.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE
10
PM5350 S/UNI-ULTRA
DATASHEET ERRATA PMC-1990107 ISSUE 4 SATURN USER NETWORK INTERFACE
CONTACTING PMC-SIERRA, INC.
PMC-Sierra, Inc. 105-8555 Baxter Place Burnaby, BC Canada V5A 4V7 Tel: Fax: (604) 415-6000 (604) 415-6200
Document Information: document@pmc-sierra.com Corporate Information: info@pmc-sierra.com Application Information: apps@pmc-sierra.com (604) 415-4533 Web Site: http://www.pmc-sierra.com
None of the information contained in this document constitutes an express or implied warranty by PMC-Sierra, Inc. as to the sufficiency, fitness or suitability for a particular purpose of any such information or the fitness, or suitability for a particular purpose, merchantability, performance, compatibility with other parts or systems, of any of the products of PMC-Sierra, Inc., or any portion thereof, referred to in this document. PMC-Sierra, Inc. expressly disclaims all representations and warranties of any kind regarding the contents or use of the information, including, but not limited to, express and implied warranties of accuracy, completeness, merchantability, fitness for a particular use, or non-infringement. In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special, incidental or consequential damages, including, but not limited to, lost profits, lost business or lost data resulting from any use of or reliance upon the information, whether or not PMC-Sierra, Inc. has been advised of the possibility of such damage. (c) 2002 PMC-Sierra, Inc. PMC-1990107 (R3) ref PMC-960924 (R5) Issue date: February 2002
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS' INTERNAL USE


▲Up To Search▲   

 
Price & Availability of 1990107

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X