![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
HIGH-SPEED 3.3V 64K x 8 SYNCHRONOUS DUAL-PORT STATIC RAM Features: x x IDT70V9089S/L x x x True Dual-Ported memory cells which allow simultaneous access of the same memory location High-speed clock to data access - Commercial: 9/12/15ns (max.) Low-power operation - IDT70V9089S Active: 429mW (typ.) Standby: 3.3mW (typ.) - IDT70V9089L Active: 429mW (typ.) Standby: 660mW (typ.) Flow-Through or Pipelined output mode on either port via the FT/PIPE pin Counter enable and reset features x x x x x Dual chip enables allow for depth expansion without additional logic Full synchronous operation on both ports - 4ns setup to clock and 1ns hold on all control, data, and address inputs - Data input, address, and control registers - Fast 9ns clock to data out in the Pipelined output mode - Self-timed write allows fast cycle time - 15ns cycle time, 66MHz operation in the Pipelined output mode LVTTL- compatible, single 3.3V (0.3V) power supply Industrial temperature range (-40C to +85C) is available for selected speeds Available in a 100 pin Thin Quad Flatpack (TQFP) package Functional Block Diagram R/WL OEL CE0L CE1L R/WR OER CE0R CE1R 1 0 0/1 1 0 0/1 FT/PIPEL 0/1 1 0 0 1 0/1 FT/PIPER I/O0L - I/O7L I/O Control I/O Control I/O0R - I/O7R A15L A0L CLKL ADSL CNTENL CNTRSTL Counter/ Address Reg. MEMORY ARRAY Counter/ Address Reg. A15R A0R CLKR ADSR CNTENR CNTRSTR 3750 drw 01 JANUARY 2001 1 (c)2000 Integrated Device Technology, Inc. DSC 3750/6 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Description: The IDT70V9089 is a high-speed 64K x 8 bit synNchronous DualPort RAM. The memory array utilizes Dual-Port memory cells to allow simultaneous access of any address from both ports. Registers on control, data, and address inputs provide minimal setup and hold times. The timing latitude provided by this approach allows systems to be designed with very short cycle times. With an input data register, the IDT70V9089 has been optimized for applications having unidirectional or bidirectional data flow in bursts. An automatic power down feature, controlled by CE0 and CE1, permits the on-chip circuitry of each port to enter a very low standby power mode. Fabricated using IDT's CMOS high-performance technology, these devices typically operate on only 429mW of power. Pin Configurations(1,2,3) Index NC NC A7L A8L A9L A10L A11L A12L A13L A14L A15L NC VCC NC NC NC NC CE0L CE1L CNTRSTL R/WL OEL FT/PIPEL NC NC 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 3 73 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 72 71 70 69 68 67 NC NC A6L A5L A4L A3L A2L A1L A0L CNTENL CLKL ADSL GND ADSR CLKR CNTENR A0R A1R A2R A3R A4R A5R A6R NC NC IDT70V9089PF PN100-1(4) 100-PIN TQFP TOP VIEW(5) 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 NC NC A7R A8R A9R A10R A11R A12R A13R A14R A15R NC GND NC NC NC NC CE0R CE1R CNTRSTR R/WR OER FT/PIPER GND NC 3750 drw 02 , NOTES: 1. All Vcc pins must be connected to power supply. 2. All GND pins must be connected to ground. 3. Package body is approximately 14mm x 14mm x 1.4mm. 4. This package code is used to reference the package diagram. 5. This text does not indicate orientation of the actual part-marking. GND NC I/O7L I/O6L I/O5L I/O4L I/O3L I/O2L GND I/OIL I/O0L VCC GND I/O0R I/O1R I/O2R VCC I/O3R I/O4R I/O5R I/O6R I/O7R NC NC NC 2 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Pin Names Left Port CE0L, CE1L R/WL OEL A0L - A15L I/O0L - I/O7L CLKL ADSL CNTENL CNTRSTL FT/PIPEL Right Port CE0R, CE1R R/WR OER A0R - A15R I/O0R - I/O7R CLKR ADSR CNTENR CNTRSTR FT/PIPER VCC GND Names Chip Enables Read/Write Enable Output Enable Address Data Input/Output Clock Address Strobe Counter Enable Counter Reset Flow-Through/Pipeline Power Ground 3750 tbl 01 Truth Table IRead/Write and Enable Control(1,2,3) OE X X X L H CLK X CE0 H X L L L CE1 X L H H H R/W X X L H X I/O0-7 High-Z High-Z DIN DOUT High-Z Mode Deselected Deselected Write Read Outputs Disabled 3750 tbl 02 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. ADS, CNTEN, CNTRST = X. 3. OE is an asynchronous input signal. Truth Table IIAddress Counter Control(1,2) Address X An An X Previous Address X X Ap Ap Addr Used 0 An Ap Ap + 1 CLK(6) ADS X L (4) CNTEN X X H L (5) CNTRST L (4) I/O(3) DI/O(0) DI/O (n) DI/O(p) DI/O(p+1) Counter Reset to Address 0 External Address Used MODE H H H H H External Address Blocked--Counter disabled (Ap reused) Counter Enabled--Internal Address generation 3750 tbl 03 NOTES: 1. "H" = VIH, "L" = VIL, "X" = Don't Care. 2. CE0 and OE = VIL; CE1 and R/W = VIH. 3. Outputs configured in Flow-Through Output mode; if outputs are in Pipelined mode the data out will be delayed by one cycle. 4. ADS is independent of all other signals including CE0 and CE1. 5. The address counter advances if CNTEN = VIL on the rising edge of CLK, regardless of all other signals including CE0 and CE1. 6.42 3 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Recommended Operating Temperature and Supply Voltage(1,2) Grade Commercial Industrial Ambient Temperature 0OC to +70OC -40OC to +85OC GND 0V 0V Vcc 3.3V + 0.3V 3.3V + 0.3V 3750 tbl 04 Recommended DC Operating Conditions Symbol VCC GND VIH VIL Parameter Supply Voltage Ground Input High Voltage Input Low Voltage Min. 3.0 0 2.2 -0.3(2) Typ. 3.3 0 ____ Max. 3.6 0 VCC + 0.3V(1) 0.8 Unit V V V V 3750 tbl 05 NOTES: 1. This is the parameter TA. This is the "instant on" case temperature. 2. Industrial temperature: for specific speeds, packages and powers contact your sales office. ____ NOTES: 1. VTERM must not exceed VCC +0.3V. 2. VIL > -1.5V for pulse width less than 10ns. Absolute Maximum Ratings(1) Symbol VTERM(2) Rating Terminal Voltage with Respect to GND Temperature Under Bias Storage Temperature DC Output Current Commercial & Industrial -0.5 to +4.6 Unit V Capacitance (TA = +25C, f = 1.0MHz) Symbol CIN COUT (3) Parameter(1) Input Capacitance Output Capacitance Conditions(2) VIN = 3dV VOUT = 3dV Max. 9 10 Unit pF pF 3750 tbl 07 TBIAS TSTG IOUT -55 to +125 -65 to +150 50 o C C o NOTES: 1. These parameters are determined by device characterization, but are not production tested. 2. 3dV references the interpolated capacitance when the input and output switch from 0V to 3V or from 3V to 0V. 3. COUT also references CI/O. mA 3750 tbl 06 NOTES: 1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. VTERM must not exceed VCC +0.3V for more than 25% of the cycle time or 10ns maximum, and is limited to < 20mA for the period of VTERM > Vcc + 0.3V. 4 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range (VCC = 3.3V 0.3V) 70V9089S Symbol |ILI| |ILO| VOL VOH Parameter Input Leakage Current(1) Output Leakage Current Output Low Voltage Output High Voltage Test Conditions VCC = 3.3V, VIN = 0V to VCC CE0 = VIH or CE1 = VIL, VOUT = 0V to VCC IOL = +4mA IOH = -4mA Min. ___ 70V9089L Min. ___ Max. 10 10 0.4 ___ Max. 5 5 0.4 ___ Unit A A V V 3750 tbl 08 ___ ___ ___ ___ 2.4 2.4 NOTE: 1. At Vcc < 2.0V input leakages are undefined. DC Electrical Characteristics Over the Operating Temperature and Supply Voltage Range(6,7) (VCC = 3.3V 0.3V) 70V9089X9 Com'l Only Symbol ICC Parameter Dynamic Operating Current (Both Ports Active) Test Condition CEL and CER = VIL Outputs Disabled f = fMAX(1) Version COM'L IND COM'L IND CE"A" = VIL and CE"B" = VIH(3) Active Port Outputs Disabled, f=fMAX(1) Both Ports CER and CEL > VCC - 0.2V VIN > VCC - 0.2V or VIN < 0.2V, f = 0(2) CE"A" < 0.2V and CE"B" > VCC - 0.2V(5) VIN > VCC - 0.2V or VIN < 0.2V, Active Port Outp uts Disabled, f = fMAX(1) COM'L IND COM'L IND COM'L IND S L S L S L S L S L S L S L S L S L S L Typ.(4) 180 180 ____ ____ 70V9089X12 Com'l Only Typ.(4) 150 150 ____ ____ 70V9089X15 Com'l Only Typ.(4) 130 130 ____ ____ Max. 260 225 ____ ____ Max. 240 205 ____ ____ Max. 220 185 ____ ____ Unit mA ISB1 Standby Current (Both Ports - TTL Level Inputs) CEL and CER = VIH f = fMAX(1) 50 50 ____ ____ 75 65 ____ ____ 40 40 ____ ____ 65 50 ____ ____ 30 30 ____ ____ 55 35 ____ ____ mA ISB2 Standby Current (One Port - TTL Level Inputs) 110 110 ____ ____ 170 150 ____ ____ 100 100 ____ ____ 160 140 ____ ____ 90 90 ____ ____ 150 130 ____ ____ mA ISB3 Full Standby Current (Both Ports CMOS Level Inputs) 1.0 0.4 ____ ____ 5 3 ____ ____ 1.0 0.4 ____ ____ 5 3 ____ ____ 1.0 0.4 ____ ____ 5 3 ____ ____ mA ISB4 Full Standby Current (One Port CMOS Level Inputs) 100 100 ____ ____ 160 140 ____ ____ 90 90 ____ ____ 150 130 ____ ____ 80 80 ____ ____ 140 120 ____ ____ mA NOTES: 1. At f = fMAX, address and control lines (except Output Enable) are cycling at the maximum frequency clock cycle of 1/tCYC, using "AC TEST CONDITIONS" at input levels of GND to 3V. 2. f = 0 means no address, clock, or control lines change. Applies only to input at CMOS level standby. 3. Port "A" may be either left or right port. Port "B" is the opposite from port "A". 4. Vcc = 3.3V, TA = 25C for Typ, and are not production tested. ICC DC(f=0) = 90mA (Typ). 5. CEX = VIL means CE0X = VIL and CE1X = VIH CEX = VIH means CE0X = VIH or CE1X = VIL CEX < 0.2V means CE0X < 0.2V and CE1X > VCC - 0.2V CEX > VCC - 0.2V means CE0X > VCC - 0.2V or CE1X < 0.2V "X" represents "L" for left port or "R" for right port. 6. 'X' in part number indicates power rating (S or L). 7. Industrial temperature: for specific speeds, packages and powers contact your sales office. 3750 tbl 09 6.42 5 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges AC Test Conditions Input Pulse Levels Input Rise/Fall Times Input Timing Reference Levels Output Reference Levels Output Load GND to 3.0V 3ns Max. 1.5V 1.5V Figures 1,2 and 3 3750 tbl 10 3.3V 3.3V 590 DATAOUT 435 30pF DATAOUT 435 590 5pF* 3750 drw 03 3750 drw 04 Figure 1. AC Output Test load. Figure 2. Output Test Load (For tCKLZ, tCKHZ, tOLZ, and tOHZ). *Including scope and jig. 8 7 6 5 tCD1, tCD2 (Typical, ns) 4 3 2 1 0 -1 -10 pF is the I/O capacitance of this device, and 30pF is the AC Test Load Capacitance 20 40 60 80 100 120 140 160 180 200 Capacitance (pF) 3750 drw 05 , Figure 3. Typical Output Derating (Lumped Capacitive Load). 6 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges AC Electrical Characteristics Over the Operating Temperature Range (Read and Write Cycle Timing)(3,4,5) (VCC = 3.3V 0.3, TA = 0C to +70C) 70V9089X9 Com'l Only Symbol tCYC1 tCYC2 tCH1 tCL1 tCH2 tCL2 tR tF tSA tHA tSC tHC tSW tHW tSD tHD tSAD tHAD tSCN tHCN tSRST tHRST tOE tOLZ tOHZ tCD1 tCD2 tDC tCKHZ tCKLZ Clock Cycle Time (Flow-Through) Clock Cycle Time (Pipelined) (2) (2) 70V9089X12 Com'l Only Min. 30 20 12 12 8 8 ____ ____ 70V9089X15 Com'l Only Min. 35 25 12 12 10 10 ____ ____ Parameter (2) Min. 25 15 12 12 6 6 ____ ____ Max. ____ ____ ____ ____ ____ ____ Max. ____ ____ ____ ____ ____ ____ Max. ____ ____ ____ ____ ____ ____ Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns Clock High Time (Flow-Through) Clock Low Time (Flow-Through) Clock High Time (Pipelined) (2) (2) Clock Low Time (Pipelined)(2) Clock Rise Time Clock Fall Time Address Setup Time Address Hold Time Chip Enable Setup Time Chip Enable Hold Time R/W Setup Time R/W Hold Time Input Data Setup Time Input Data Hold Time ADS Setup Time ADS Hold Time CNTEN Setup Time CNTEN Hold Time CNTRST Setup Time CNTRST Hold Time Output Enable to Data Valid Output Enable to Output Low-Z(1) Output Enable to Output High-Z (1) (2) 3 3 ____ ____ ____ ____ ____ ____ ____ ____ ____ 3 3 ____ ____ ____ ____ ____ ____ ____ ____ ____ 3 3 ____ ____ ____ ____ ____ ____ ____ ____ ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ 4 1 4 1 4 1 4 1 4 1 4 1 4 1 ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 12 ____ 12 ____ 15 ____ 2 1 ____ ____ 2 1 ____ ____ 2 1 ____ ____ 7 20 9 ____ 7 25 12 ____ 7 30 15 ____ Clock to Data Valid (Flow-Through) Clock to Data Valid (Pipelined) (2) Data Output Hold After Clock High Clock High to Output High-Z (1) 2 2 2 2 2 2 2 2 2 9 ____ 9 ____ 9 ____ Clock High to Output Low-Z(1) Port-to-Port Delay tCWDD tCCS Write Port Clock High to Read Data Delay Clock-to-Clock Setup Time ____ ____ 35 15 ____ ____ 40 15 ____ ____ 50 20 ns ns 3750 tbl 11 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). This parameter is guaranteed by device characterization, but is not production tested. 2. The Pipelined output parameters (tCYC2, tCD2) apply to either or both left and right ports when FT/PIPE = VIH. Flow-through parameters (tCYC1, tCD1) apply when FT/PIPE = VIL for that port. 3. All input signals are synchronous with respect to the clock except for the asynchronous Output Enable (OE) and FT/PIPE. FT/PIPE should be treated as a DC signal, i.e. steady state during operation. 4. 'X' in part number indicates power rating (S or L). 5. Industrial temperature: for specific speeds, packages and powers contact your sales office. 6.42 7 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Read Cycle for Flow-Through Output (FT/PIPE"X" = VIL)(3,6) tCYC1 tCH1 CLK CE0 tSC CE1 tHC tSC (4) tCL1 tHC R/W tSW tSA tHW tHA An + 1 tCD1 tDC Qn tCKLZ (1) ADDRESS (5) An An + 2 An + 3 tCKHZ (1) DATAOUT Qn + 1 tOHZ (1) Qn + 2 tOLZ (1) tDC OE (2) tOE 3750 drw 06 Timing Waveform of Read Cycle for Pipelined Output (FT/PIPE"X" = VIH)(3,6) tCYC2 tCH2 CLK CE0 tSC CE1 tHC tCL2 tSC (4) tHC R/W tSW tSA tHW tHA An + 1 (1 Latency) tCD2 Qn tCKLZ (1) ADDRESS (5) An An + 2 tDC Qn + 1 An + 3 DATAOUT Qn + 2 (1) tOHZ tOLZ (1) OE (2) tOE 3750 drw 07 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. OE is asynchronously controlled; all other inputs are synchronous to the rising clock edge. 3. ADS = VIL, CNTEN and CNTRST = VIH. 4. The output is disabled (High-impedance state) by CE0 = VIH or CE1 = VIL following the next rising edge of clock. Refer to Truth Table 1. 5. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 6. "x" denotes Left or Right port. The diagram is with respect to that port. 8 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of a Bank Select Pipelined Read(1,2) tCH2 CLK tSA ADDRESS(B1) tSC CE0(B1) tCD2 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 Q0 tDC tHA A0 tHC tSC tHC tCD2 tCKHZ Q1 tDC (3) tCYC2 tCL2 A1 A2 A3 A4 A5 A6 tCD2 Q3 tCKLZ (3) tCKHZ (3) tSC CE0(B2) tSC tHC tHC tCD2 DATAOUT(B2) tCKLZ(3) Q2 tCKHZ(3) tCD2 tCKLZ (3) Q4 3750 drw 08 Timing Waveform of a Bank Select Flow-Through Read(6) tCH1 CLK tSA ADDRESS(B1) tSC tHA A0 tHC tSC tCD1 DATAOUT(B1) tSA ADDRESS(B2) tHA A0 A1 A2 A3 A4 A5 A6 D0 tDC tCD1 D1 tDC tCKLZ (1) tCYC1 tCL1 A1 A2 A3 A4 A5 A6 CE0(B1) tHC tCKHZ (1) tCD1 D3 tCKHZ (1) tCD1 D5 tCKLZ (1) tSC CE0(B2) tSC tHC tHC tCD1 DATAOUT(B2) tCKLZ (1) tCKHZ D2 (1) tCD1 tCKLZ (1) tCKHZ D4 (1) NOTES: 1. B1 Represents Bank #1; B2 Represents Bank #2. Each Bank consists of one IDT70V9089 for this waveform, and are setup for depth expansion in this example. ADDRESS(B1) = ADDRESS(B2) in this situation. 2. OE and ADS = VIL; CE1(B1), CE1(B2), R/W, CNTEN, and CNTRST = VIH. 3. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 4. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 5. OE = VIL for the Right Port, which is being read from. OE = VIH for the Left Port, which is being written to. 6. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 3750 drw 08a 6.42 9 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform Port-to-Port Flow-Through Read(1,2,3,5) CLK "A" tSW tHW R/W "A" tSA ADDRESS "A" tHA NO MATCH MATCH tSD DATAIN "A" tHD VALID tCCS (4) CLK "B" tCD1 R/W "B" tSW tHW tSA ADDRESS "B" tHA NO MATCH MATCH tCWDD (4) DATAOUT "B" tDC VALID tCD1 VALID tDC 3750 drw 09 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 3. OE = VIL for the Port "B", which is being read from. OE = VIH for the Port "A", which is being written to. 4. If tCCS < maximum specified, then data from right port READ is not valid until the maximum specified for tCWDD. If tCCS > maximum specified, then data from right port READ is not valid until tCCS + tCD1. tCWDD does not apply in this case. 5. All timing is the same for both left and right ports. Port "A" may be either left or right port. Port "B" is the opposite of Port "A". 10 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read-to-Write-to-Read (OE = VIL)(3) tCYC2 tCH2 tCL2 CLK CE0 tSC tHC CE1 tSW tHW R/W tSW tHW ADDRESS (4) An tSA tHA An +1 An + 2 An + 2 tSD tHD Dn + 2 An + 3 An + 4 DATAIN (2) tCD2 Qn READ tCKHZ (1) tCKLZ (1) tCD2 Qn + 3 DATAOUT NOP (5) WRITE READ 3750 drw 10 Timing Waveform of Pipelined Read-to-Write-to-Read (OE Controlled)(3) tCH2 CLK CE0 tSC CE1 tSW tHW R/W tSW tHW tHC tCYC2 tCL2 ADDRESS(4) An tSA tHA An +1 An + 2 tSD tHD An + 3 An + 4 An + 5 DATAIN (2) tCD2 Qn tOHZ (1) Dn + 2 Dn + 3 tCKLZ(1) tCD2 Qn + 4 DATAOUT OE READ WRITE READ 3750 drw 11 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 6.42 11 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Flow-Through Read-to-Write-to-Read (OE = VIL)(3) tCH1 CLK tCYC1 tCL1 CE0 tSC CE1 tSW tHW R/W tSW tHW tHC ADDRESS (4) An tSA tHA An +1 An + 2 An + 2 tSD tHD An + 3 An + 4 DATAIN (2) Dn + 2 tCD1 Qn tDC READ tCD1 Qn + 1 tCKHZ NOP (5) (1) tCD1 Qn + 3 tDC READ tCD1 DATAOUT tCKLZ WRITE (1) 3750 drw 12 Timing Waveform of Flow-Through Read-to-Write-to-Read (OE Controlled)(3) tCYC1 tCH1 tCL1 CLK CE0 tSC tHC CE1 tSW tHW R/W tSW tHW ADDRESS (4) An tSA tHA An +1 An + 2 tSD tHD Dn + 2 An + 3 An + 4 An + 5 DATAIN (2) Dn + 3 tCD1 Qn tDC tOE tCD1 (1) tCD1 Qn + 4 tDC DATAOUT tOHZ (1) OE READ WRITE tCKLZ READ 3750 drw 13 NOTES: 1. Transition is measured 0mV from Low or High-impedance voltage with the Output Test Load (Figure 2). 2. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 3. CE0 and ADS = VIL; CE1, CNTEN, and CNTRST = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. "NOP" is "No Operation." Data in memory at the selected address may be corrupted and should be re-written to guarantee data integrity. 12 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Pipelined Read with Address Counter Advance (1) tCH2 CLK tSA ADDRESS An tSAD tHAD ADS tSAD tHAD tHA tCYC2 tCL2 CNTEN tCD2 DATAOUT Qx - 1(2) Qx tDC READ EXTERNAL ADDRESS READ WITH COUNTER Qn tSCN tHCN Qn + 1 Qn + 2(2) Qn + 3 COUNTER HOLD READ WITH COUNTER 3750 drw 14 Timing Waveform of Flow-Through Counter Read with Address Counter Advance(1) tCH1 CLK tSA ADDRESS tHA tCYC1 tCL1 An tSAD tHAD ADS tSAD tHAD tSCN tHCN CNTEN tCD1 DATAOUT Qx(2) tDC READ EXTERNAL ADDRESS READ WITH COUNTER COUNTER HOLD READ WITH COUNTER 3750 drw 15 Qn Qn + 1 Qn + 2 Qn + 3(2) Qn + 4 NOTES: 1. CE0 and OE = VIL; CE1, R/W, and CNTRST = VIH. 2. If there is no address change via ADS = VIL (loading a new address) or CNTEN = VIL (advancing the address), i.e. ADS = VIH and CNTEN = VIH, then the data output remains constant for subsequent clocks. 6.42 13 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Timing Waveform of Write with Address Counter Advance (Flow-Through or Pipelined Outputs) (1) tCH2 CLK tSA ADDRESS tHA tCYC2 tCL2 An INTERNAL(3) ADDRESS tSAD tHAD ADS An(7) An + 1 An + 2 An + 3 An + 4 CNTEN tSD tHD DATAIN Dn WRITE EXTERNAL ADDRESS Dn + 1 Dn + 1 Dn + 2 Dn + 3 Dn + 4 WRITE WRITE WITH COUNTER COUNTER HOLD WRITE WITH COUNTER 3750 drw 16 Timing Waveform of Counter Reset (Pipelined Outputs)(2) tCH2 CLK tSA tHA (4) tCYC2 tCL2 ADDRESS INTERNAL(3) ADDRESS R/W ADS CNTEN tSCN tHCN tSRST tHRST CNTRST DATAIN (5) An Ax (6) tSW tHW An + 1 An + 2 0 1 An An + 1 tSAD tHAD tSD tHD D0 Q0 Q1 READ ADDRESS n READ ADDRESS n+1 Qn DATAOUT COUNTER RESET (6) WRITE ADDRESS 0 READ ADDRESS 0 READ ADDRESS 1 NOTES: 3750 drw 17 1. CE0 and R/W = VIL; CE1 and CNTRST = VIH. 2. CE0 = VIL; CE1 = VIH. 3. The "Internal Address" is equal to the "External Address" when ADS = VIL and equals the counter output when ADS = VIH. 4. Addresses do not have to be accessed sequentially since ADS = VIL constantly loads the address on the rising edge of the CLK; numbers are for reference use only. 5. Output state (High, Low, or High-impedance) is determined by the previous cycle control signals. 6. No dead cycle exists during counter reset. A READ or WRITE cycle may be coincidental with the counter reset.ADDR0 will be accessed. Extra cycles are shown here simply for clarification. 7. CNTEN = VIL advances Internal Address from `An' to `An +1'. The transition shown indicates the time required for the counter to advance. The `An +1' address is written to during this cycle. 14 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Functional Description The IDT70V9089 provides a true synchronous Dual-Port Static RAM interface. Registered inputs provide minimal set-up and hold times on address, data, and all critical control inputs. All internal registers are clocked on the rising edge of the clock signal, however, the self-timed internal write pulse is independent of the LOW to HIGH transition of the clock signal. An asynchronous output enable is provided to ease asynchronous bus interfacing. Counter enable inputs are also provided to stall the operation of the counter registers for fast interleaved memory applications. A HIGH on CE0 or a LOW on CE1 for one clock cycle will power down the internal circuitry to reduce static power consumption. Multiple chip enables allow easier banking of multiple IDT70V9089's for depth expansion configurations. When the Pipelined output mode is enabled, two cycles are required with CE0 LOW and CE1 HIGH to re-activate the outputs. Depth and Width Expansion The IDT70V9089 features dual chip enables (refer to Truth Table I) in order to facilitate rapid and simple depth expansion with no requirements for external logic. Figure 4 illustrates how to control the various chip enables in order to expand two devices in depth. The IDT70V9089 can also be used in applications requiring expanded width, as indicated in Figure 4. Since the banks are allocated at the discretion of the user, the external controller can be set up to drive the input signals for the varioius devices as required to allow for 16-bit or wider applications. A16 IDT70V9089 CE0 CE1 VCC IDT70V9089 CE0 CE1 VCC Control Inputs Control Inputs IDT70V9089 CE1 CE0 IDT70V9089 CE1 CE0 CNTRST CLK ADS CNTEN R/W OE Control Inputs Control Inputs 3750 drw 18 Figure 4. Depth and Width Expansion with IDT70V9089 6.42 15 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Ordering Information IDT XXXXX Device Type A Power 99 Speed A Package A Process/ Temperature Range Blank I(1) Commercial (0C to +70C) Industrial (-40C to +85C) PF 100-pin TQFP (PN100-1) 9 12 15 S L Commercial Only Commercial Only Commercial Only Standard Power Low Power Speed in nanoseconds 70V9089 512K (64K x 8-Bit) Synchronous Dual-Port RAM 3750 drw 19 NOTE: 1. Industrial temperature range is available. For specific speeds, packages and powers contact your sales office. Ordering Information for Flow-through Devices Old Flow-through Part 70V908S/L25 70V908S/L30 New Combined Part 70V9089S/L12 70V9089S/L15 3750 tbl 12 16 6.42 IDT70V9089S/L High Speed 3.3V 64K x 8 Synchronous Dual-Port Static RAM Industrial and Commercial Temperature Ranges Datasheet Document History 1/18/99: Initiated datasheet document history Converted to new format Cosmetic and typographical corrections Added additional notes to pin configurations Page 14 Added Depth and Width Expansion section. Page 3 Deleted note 6 for Table II Replaced IDT logo Combined Pipelined 70V9089 family and Flow-through 70V908 family offerings into one data sheet Changed 200mV in waveform notes to 0mV Added corresponding part chart with ordering information Page 3 Changed information in Truth Table II Page 4 Increased storage temperature parameters Clarified TA parameter Page 5 DC Electrical parameters-changed wording from "open" to "disabled" Removed Preliminary Status 6/11/99: 11/12/99: 3/31/00: 1/10/01: CORPORATE HEADQUARTERS 2975 Stender Way Santa Clara, CA 95054 for SALES: 800-345-7015 or 408-727-6116 fax: 408-492-8674 www.idt.com for Tech Support: 831-754-4613 DualPortHelp@idt.com The IDT logo is a registered trademark of Integrated Device Technology, Inc. 6.42 17 |
Price & Availability of 70V9089DS82476
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |