Part Number Hot Search : 
C68HC711 AD8228 SM120 EL5246CY CR306 M62499 TDA381 3850A07
Product Description
Full Text Search
 

To Download 9385 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 GS-NT1+/DF3
POWER MANAGEMENT MODULE FOR ISDN NT1+
REV. 01 Type Vi Vo Io
40V
1804.5W 720mW 900mW 100mW 700mW
5V - 21V - 50V - 135V
NT1+/DF3
FEATURE s COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION s Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power Mode) AND RPM (Restricted Power Mode) CONDITIONS s INPUT FILTER TO MEET EMC REQUIREMENTS s 5 INSULATED MAIN OUTPUTS s PEAK INPUT OVERVOLTAGE WITHSTANDING s INPUT FUSE ON AC MAIN INPUT s INPUTS TO OUTPUTS INSULATION s AUXILIARY LOGIC OUTPUT TTLCOMPATIBLE FOR NPM/RPM MODE INDICATION (EM SIGNAL & GREEN LED). 3mA OUTPUT SOURCE CURRENT s AUXILIARY LOGIC OUTPUT TTLCOMPATIBLE FOR U-INTERFACE DETECTION (RED LED. 3mA OUTPUT SOURCE CURRENT s INTERNAL RELAY FUNCTION FOR Vo1 POLARITY REVERSE s ANALOG OUTPUTS EMERGENCY CONDITION PROGRAMMABLE VIA EXTERNAL COMMAND, TTL-COMPATIBLE, 1mA SINK CURRENT s U-INTERFACE ACCORDING TO ETR 080 WITH EXTERNAL CAPACITOR February 2003
ORDERING NUMBER: GS-NT1+/DF3
s
MECHANICAL DIMENSIONS (LxWxH):96x58x26.6
DESCRIPTION The NT1+/DF3 Power Management Module is a comprehensive solution for ISDN-NT1 "Plus" (Network Termination Basic Access type Plus) equipment, combining both AC-DC and DC-DC functions. The NT1+/DF3 Power Management Module (NT1+ PMM) provide the NT1+ equipment with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the Normal Power Mode (NPM) and Restricted Power Mode (RPM). Connected to the main, Input 1 is the AC input power to the NT1+ PMM, source of the whole necessary power in normal operating mode, namely in NPM. Input 2 is the DC power source when in RPM, therefore to connect to the U-INTERFACE. When the main is available (230 Vac in this version) NT1+ PMM operate in Normal Power Mode, therefore it supply +40V (output 1) to the S-interface being the output power 4.5 W. Output 2 delivers 5V (up to 720 mW) for the logics and output 3 delivers -21V (up to 900 mW). Out voltage 4 is -50V with 100 mW output power. Last, output 5 delivers -135V and the output power can reach peaks of 700 mW.
1/10
This is preliminary information on a new product now in development. Details are subject to change without notice.
GS-NT1+/DF3
When the main is missing, the module remains active but only in Restricted Power Mode (RPM). The only power source in RPM is the Input 2, the U-Interface (Vi2). Therefore in RPM the following condition apply to outputs 1 and 2: output 1 reverses the voltage (it becomes -40V) and the maximum power Pout is reduced to 420 mW. P2max is reduced to 450 mW typically, however the output power available at outputs 2, 3, 4, 5 mainly depend on input power available from the"U-Interface" Vi2, therefore subject of variation as per local application and regulation. In RPM it is also possible to set a different "emergency condition" setting HIGH the auxiliary input 3 (analog emergency input, Vin3). In this case Pout1 is reduced to 25 mW, voltage level being -40V. The following tables give you details of the various parameters in the 3 different operating modes, namely NPM with Vi3 LOW, RPM with Vi3 HIGH. Availability of the input AC main is also acknowledged by specific auxiliary output (out 6, "EM signal"), a TTLcompatible signal set HIGH (to logic level "1") when the main is available and LOW when th AC main is missing. The presence of the "U" is detected by an other auxiliary output (out 7) that is HIGH only when Vin2>34 Vdc. The NT1+ PMM provides double insulation (3000 Vrms) between the inputs (1 and 2), and among the input 1 and all the outputs. Basic insulation 2000 Vdc exist among Out 1 and all the other outputs. The other outputs (including the 2 auxiliary outputs) and the input 3, share the same common ground. Double insulation (2000 Vrms) is provided among Input 2 (DC "U") and all outputs. The NT1+ Power Management Module operate in the range -10 to +70C, storage temperatures in the range -40 to +85C are allowed.
2/10
GS-NT1+/DF3
ELECTRICAL CHARACTERISTICS when in NPM (Tamb=25)C, unless otherwise specified.) NPM Standard Condotion: Vin1=180 to 264 Vrms -------------Vin2=40 to 120 Vdc
Symbol Vi1 Vi2 fi Vi1st Pi1 Vi2nd Vo1 Vo2 Vo3 Vo4 Vo5 Vo6 Vo7 Vor1,3,4,5 Vor2 Po1 Po2 Po3 Po4 Po5 Parameter AC Input Voltage 1 DC Input Voltage 2 Vi1 Input Frequency Start up Input 1 voltage Input 1 Apparent Power Start up Input 2 voltage Output Voltage 1 Output Voltage 2 Output Voltage 3 Output Voltage 4 Output Voltage 5 Auxiliary Output 6(EM) Auxiliary Output 7(red LED) Output Ripple voltage 1,3,4,5 Output Ripple voltage 2 Output Power 1 Output Power 2 Output Power 3 Output Power 4 Output Power 5 any polarity Vi1 = 230 VRMS Output parameters as per NPM Standard Condition NPM Standard Condition Output parameters as per Standard Condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition BW: 0-20 MHz Standard condition BW: 0-20 MHz Std. condition according to ETS300 012, E5.1.5, E5.1.6, E5.1.7 (n=4) Standard condition Standard condition Standard condition During 1 s, 40% of the time during the ring period at the analog interface. The output is current limited at 2.5 mA 0.2 mA, with 100 uF capacitor Output parameters as per Standard Condition transition NPM => RPM and vice versa according to ETS300 012, E5.1.3 (n=4) t = 10/700 us as per 1TR9 Dec. 96 common mode test according to ETS300 047-5p5.6 2000 2500 4.5 720 900 100 700 34 4.75 -20 -48 -130 3.75 3.75 40 5 -21 -50 -135 5 5 Test Condition Min. 180 40 43 Typ. Max. 264 120 56 175 15 40 42 5.25 -24 -65 -170 5.25 5.25 100 30 Unit VRMS Vdc Hz VRMS VA Vdc V V V V V V V mVrms mVrms W mW mW mW mW
Vi1th Ttr
NPM => RPM mode Vi1 threshold Transition time
160 5
Vrms ms
Vi1pk Vi1pk
Input 1 Transient overvoltage Input 1 Transient overvoltage
V V
3/10
GS-NT1+/DF3
Symbol
Vi1pk Vo1pk Vis
Parameter
Input 1 Transient overvoltage Output 1 Transient overvoltage Insulation Voltage
Test Condition
impuls transfer from main according to ETS300 047-5p5.7.1 t=1.2/50 us Input 1 to outputs and input 1 to input 2, t=60s reinforced insulation as per EN60950 Input 1 to outputs t=10/700 us (pulse) Vin = 180 VRMS Standard Condition Ground Fixed, MIL-HDBK-217E
Min.
2500 500 3000
Typ.
Max.
Unit
V V V
Vist th MTBF Top
Insulation Voltage Hold-up time Mean Time Before Failure Oper. Ambient Temperature
4000 20 1 -10 +70
V ms Mh
C
4/10
GS-NT1+/DF3
ELECTRICAL CHARACTERISTICS when in RPM (Tamb=25)C, unless otherwise specified.) RPM Standard Condition: Vin1 < 100 Vrms -------------Vin2 = 28 to 115 Vdc ------------------Vin3 = LOW
Symbol Vi1 Vi2 Vi2nd Vo1 Vo2 Vo3 Vo4 Vo5 Vo6 Vo7 Vor1,3,4,
5
Parameter AC Input Voltage 1 DC Input Voltage 2 Start up Input 2 voltage Output Voltage 1 Output Voltage 2 Output Voltage 3 Output Voltage 4 Output Voltage 5 Auxiliary Output 6 (EM) Auxiliary Output 7 (red LED) Output Ripple Voltage 1,3,4,5 Output Ripple Voltage 2 Output Power 1 Output Power 2 Output Power 3 Output Power 4 Output Power 5 RPM => NPM mode Vi1 threshold Transition TIme Input 1 Transient overvoltage Input 1 Transient overvoltage Input 1 Transient overvoltage any polarity
Test Condition
Min.
Typ.
Max. 100
Unit Vrms Vdc Vdc V V V V V V V mVrms mVrms mW mW mW mW mW
40
120 48
Output parameters as per Std. Condition Standard Condition Standard Condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition BW :0-20 MHz Standard condition BW:0-20 Mhz Std. condition according to ETS300 012, E5.1.1, E5.1.4.1, E5.1.4.2, E5.1.5.3 (n=4) Standard Condition Standard Condition Standard Condition Standard Condition Output parameters as per Standard Condition transition NPM => RPM and vice versa according to ETS300 012, E5.1.3 (n=4) t = 10/700 us as per 1TR9 Dec. 96 common mode test according to ETS300 047-5p5.6 impuls transfer from main according to ETS300 047-5p5.7.1 2000 2500 2500 500 3000 420 450 tbd tbd tbd -34 4.75 -20 -48 -130 3.75 3.75 -40 5 -21 -50 -135 5 5
-42 5.25 -24 -65 -170 5.25 5.25 100 30
Vor2 Po1 Po2 Po3 Po4 Po5 Vi1st Ttr Vi1pk Vi1pk Vi1pk Vo1pk Vis
175 5
Vrms ms V V V V V
Output 1 Transient overvoltage t=1.2/50 us Insulation Voltage Input 1 to outputs and input 1 to input 2, t=60s reinforced insulation as per EN60950 Input 1 to outputs t=10/700 us (pulse) Vin = 180 Vrms Standard Condition
Vist th
Insulation Voltage Hold-up time
4000 20
V ms
5/10
GS-NT1+/DF3
Symbol MTBF Top Parameter Mean Time Before Failure Oper. Ambient Temperature Storage Temperature Range Test Condition Ground Fixed, MIL-HDBK-217E Min. 1 -10 -40 +70 +85 Typ. Max. Unit Mhours

C C
Tstg
ELECTRICAL CHARACTERISTICS when in RPM (Tamb=25)C, unless otherwise specified.)
6/10
GS-NT1+/DF3
RPM Standard Condition: Vin1 < 100 Vrms-----------Vin2 = 40 to 120 Vdc------------Vin3 = HIGH
Symbol Vi1 Vi2 Vi2nd Vo1 Vo2 Vo3 Vo4 Vo5 Vo6 Vo7 Parameter AC Input Voltage 1 DC Input Voltage 2 Start up Input 2 voltage Output Voltage 1 Output Voltage 2 Output Voltage 3 Output Voltage 4 Output Voltage 5 Auxiliary Output 6 (EM) Auxiliary Output 7 (red LED) any polarity Output parameters as per Std. Condition Standard Condition Standard Condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition BW :0-20 MHz Standard condition BW:0-20 Mhz Std. condition Standard Condition Standard Condition Standard Condition Standard Condition 25 450 tbd tbd tbd 175 5 3.75 5 -34 4.75 -20 -48 -130 -40 5 -21 -50 -135 40 Test Condition Min. Typ. Max. 100 120 40 -42 5.25 -24 -65 -170 1.25 5.25 100 30 Unit Vrms Vdc Vdc V V V V V V V mVrms mVrms mW mW mW mW mW Vrms ms
Vor1,3,4,5 Output Ripple Voltage 1,3,4,5 Vor2 Po1 Po2 Po3 Po4 Po5 Vi1st Ttr Output Ripple Voltage 2 Output Power 1 Output Power 2 Output Power 3 Output Power 4 Output Power 5
RPM => NPM mode Vi1 threshold Output parameters as per Standard Condition Transition time transition NPM => RPM and vice versa according to ETS300 012, E5.1.3 (n=4) t = 10/700 us as per 1TR9 Dec. 96 common mode test according to ETS300 047-5p5.6 impuls transfer from main according to ETS300 0475p5.7.1 t=1.2/50 us Input 1 to outputs and input 1 to input 2, t=60s reinforced insulation as per EN60950 2000 2500 2500
Vi1pk Vi1pk Vi1pk
Input 1 Transient overvoltage Input 1 Transient overvoltage Input 1 Transient overvoltage
V V V
Vo1pk Vis
Output 1 Transient overvoltage Insulation Voltage
500 3000
V V
7/10
GS-NT1+/DF3
Symbol
Vist th MTBF Top
Parameter
Insulation Voltage Hold-up time Mean Time Before Failure Oper. Ambient Temperature Storage Temperature Range
Test Condition
Input 1 to outputs t=10/700 us (pulse) Vin = 180 Vrms Standard Condition Ground Fixed, MIL-HDBK-217E
Min.
4000 20 1 -10 -40
Typ.
Max.
Unit
V ms Mhours
+70 +85
C C
Tstg
Figure 1. NT1 Plus Power Management Module TOP VIEW (dimensions in mm)
8/10
GS-NT1+/DF3
Figure 2. NT1 Plus Power Management Module SIDE VIEW (dimensions in mm)
PIN CONFIGURATION
Pin No 1 2 3 4 5 6, 9 7 8 10 11 Output 5 (-135 V) Output 6 (EM, Green LED) Vin3, Analog Emergency Input 3 Output 3 (-21 V) Output 4 (-50 V) GND, Common return for pins 1, 2, 3, 4, 5, 7, 8, 10, 21 Output 2 (+5 V) Rele` Output 7 (RED LED) Output 1 ( 40 V) S-interface Signal Pin No 12 13 14 15 16 17 18 19 20 21 N.C. N.C. Output 1 return (0 V) S-interface N.C. N.C. Vi2 Input Voltage 2, Vdc (any polarity) Vi2 Input Voltage 2, Vdc (any polarity) Vi1 Input Voltage 1, VAC Vi1 Input Voltage 1, VAC Vring ON/OFF Signal
9/10
GS-NT1+/DF3
Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics. The ST logo is a registered trademark of STMicroelectronics (R) 2003 STMicroelectronics - All Rights Reserved STMicroelectronics GROUP OF COMPANIES Australia - Brazil - Canada - China - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan - Malaysia - Malta - Morocco Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A. http://www.st.com
10/10


▲Up To Search▲   

 
Price & Availability of 9385

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X