![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MMA712 DC to 12 GHz Amplifier 712 2012 PACKAGE 712 CM22 PACKAGE NOT TO SCALE Description: The MMA712 is a fully matched Darlington Amplifier, constructed with reliable InGaP-GaAs HBT technology. Exhibits extremely flat gain response over the operating band. Features: * * * DC - 12 GHz Broadband Gain Block. Flat gain over bandwidth +/- 1 dB. 50 Ohm match Input/Output RF Specifications (TA = +25 C): Parameter Frequency Range Gain VSWR Power Output OIP3 Noise Figure DC Supply current Temperature Range NOTES: Minimum DC DC 11 --+10 +16 --42 -40 Typical ----12 1.50:1 +11 +23 5.5 48 --- Maximum 12 11 14 2.40:1 --+25 6.5 55 +85 Units GHz GHz dB --dBm dBm dB mA C Test Conditions CM22 Package 2012 Package Input/Output P-1 dBGCP Vs = 6.00 V, Rbias = 22 1. Vs = 6.00 Vdc, Rbias = 22 2. IMD testing with a frequency separation of 1.22 MHz and an output power of 0 dBm/tone Absolute Maximum Ratings: Parameters DC voltage (Vcc) RF Input Power, continuous Operating Temperature Storage Temperature Rating +5.20 V +10 dBm -40 to +85 C -55 to +125 C Revision Date: 6/6/04 MMA712 DC to 12 GHz Amplifier RF Performance, CM22 Package: Figure 1. Gain vs Temperature 15 +25C +85C -40C Figure 2. Input VSWR vs Temperature 2.4 +25C +85C -40C 14 2.2 13 11 INPUT VSWR 12 2 1.8 Gain, dB 10 9 1.6 8 1.4 7 6 1.2 5 1 0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12 Frequency (GHz) Frequency (GHz) Figure 3. Output VSWR vs Temperature 2.4 +25C +85C -40C Figure 4. Output Power vs Temperature 18 +25C +85C -40C 16 Pout @ -1dBGCP, dBm 2.2 OUTPUT VSWR 14 12 10 8 6 4 2 0 2 1.8 1.6 1.4 1.2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 0 1 2 3 4 5 6 7 8 9 10 11 12 Frequency (GHz) Frequency (GHz) Figure 5. Noise Figure vs Temperature 9.0 8.0 Figure 5. 3rd Order Intercept vs Temperature 35 +25C 30 +85C -40C NOISE FIGURE, dB 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0 1 2 3 4 5 6 7 8 9 10 11 +25C +85C -40C OIP3, dBmn 25 20 15 10 5 0 12 0 1 2 3 4 5 6 7 8 9 10 11 Frequency (GHz) Frequency (GHz) 2 Aeroflex / Metelics, Inc., 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181* FAX: 408-733-7645 * sales@aeroflex-metelics.com * www.aeroflex-metelics.com Revision Date: 6/6/04 MMA712 DC to 12 GHz Amplifier RF Performance, 2012 Package: Figure 7. Gain vs Temperature 15 +25C +85C -40C Figure 8. Input VSWR vs Temperature 3 2.8 2.6 +25C +85C -40C 14 13 12 INPUT VSWR 0 1 2 3 4 5 6 7 8 9 10 11 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0 Gain, dB 11 10 9 8 7 6 5 1 2 3 4 5 6 7 8 9 10 11 Frequency (GHz) Frequency (GHz) Figure 9. Output VSWR vs Temperature 3.4 3.2 +25C +85C -40C Figure 10. Output Power vs Temperature 18 +25C +85C -40C Pout @ -1dBGCP, dBm 3 16 14 12 10 8 6 4 2 0 OUTPUT VSWR 2.8 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11 12 Frequency (GHz) Frequency (GHz) Figure 11. Noise Figure vs Temperature 9.0 8.0 Figure 12. 3rd Order Intercept vs Temperature 35 30 25 NOISE FIGURE, dB 7.0 6.0 5.0 4.0 3.0 2.0 5 1.0 +25C +85C -40C +25C +85C -40C OIP3, dBm 20 15 10 0 0 1 2 3 4 5 6 7 8 9 10 11 0.0 0 1 2 3 4 5 6 7 8 9 10 11 Frequency (GHz) Frequency (GHz) Aeroflex / Metelics, Inc., 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181* FAX: 408-733-7645 * sales@aeroflex-metelics.com * www.aeroflex-metelics.com 3 Revision Date: 6/6/04 MMA712 DC to 12 GHz Amplifier 2012 Package Dimensions: . ) . . I Lead Finish is Pd/Ni (Pd = 0.020-0.150 m, Ni = 0.5-2.0 m) CM22 Package Dimensions: 4 Aeroflex / Metelics, Inc., 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181* FAX: 408-733-7645 * sales@aeroflex-metelics.com * www.aeroflex-metelics.com Revision Date: 6/6/04 MMA712 DC to 12 GHz Amplifier 2012 Footprint: 0.50-0.02 Aeroflex / Metelics, Inc., 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181* FAX: 408-733-7645 * sales@aeroflex-metelics.com * www.aeroflex-metelics.com 5 Revision Date: 6/6/04 MMA712 DC to 12 GHz Amplifier Application Circuit: C5 0.1uF Vs = 6.00VDC C4 100pF C3 10pF RBIAS 22 Ohms L1 C1 RF IN MMA712 C2 RF OUT C1, C2, L1: Set by lowest operating frequency. Bias Resistor Value vs Supply Voltage: Vs (V) Rbias () Power Dissipation (W) 6.00 22 0.10 8.00 10.00 12.00 15.00 43 0.2 86 0.5 130 1 200 2 6 Aeroflex / Metelics, Inc., 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181* FAX: 408-733-7645 * sales@aeroflex-metelics.com * www.aeroflex-metelics.com Revision Date: 6/6/04 Aeroflex / Metelics Aeroflex Microelectronic Solutions 975 Stewart Drive, Sunnyvale, CA 94085 TEL: 408-737-8181 Fax: 408-733-7645 www.aeroflex-metelics.com sales@aeroflex-metelics.com Aeroflex / Metelics, Inc. reserves the right to make changes to any products and services herein at any time without notice. Consult Aeroflex or an authorized sales representative to verify that the information in this data sheet is current before using this product. Aeroflex does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or service from Aeroflex convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual rights of Aeroflex or of third parties. Copyright 2003 Aeroflex / Metelics. All rights reserved. Our passion for performance is defined by three attributes represented by these three icons: solution-minded, performance-driven and customer-focused. Revision Date: 6-6-04 |
Price & Availability of MMA712
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |