![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
2-Line Filters for Installations and Systems Power line filters for single-phase systems with additional LF suppression Rated voltage 250 V~, 50/60 Hz Rated current 2 A to 36 A Construction s Two-line filter s Metal case s Polyurethane potting (UL 94 V-0) B84299-K61 ... B84299-K67 Features s Especially high differential-mode insertion loss from 20 kHz upwards s Safe mounting by press-in nuts s Space-saving design Applications s Switch-mode power supplies for traction, safety systems, automation engineering s Industrial electronics Terminals s Litz wires Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, date code Minimum marking on packaging: Manufacturer's logo, ordering code Circuit diagram LINE Blue Blau N LOAD Blue Blau N' L Schwarz Black L' Black Schwarz SSB0591-E 212 03/01 2-Line Filters for Installations and Systems Technical data Rated voltage V R Rated current I R Test voltage V P Leakage current l leak Climatic category 250 V~, 50/60 Hz Referred to 40 C ambient temperature 1414 V-, 2 s (line/line) 2830 V-, 2 s (lines/case) at 230 V~, 50 Hz B84299-K61 ... B84299-K67 In accordance with EN 60068-1 25/085/21 (- 25 C/+ 85 C/21 days damp heat test) Characteristics and ordering codes IR A 2 4 6 10 16 25 36 R typ m 530 150 110 50 35 27 12 Approx. weight kg 0,35 0,37 0,82 1 1,8 2,9 2,9 l leak mA Ordering code Approvals 565-3 < 3,5 < 3,5 < 3,5 < 3,5 < 3,5 < 3,5 < 10 B84299-K61-C B84299-K62-C B84299-K63 B84299-K64-C B84299-K65 B84299-K66 B84299-K67 x x -- -- -- -- -- -- -- x x -- -- -- x = approval granted 213 03/01 2-Line Filters for Installations and Systems Dimensional drawings B84299-K61-C, B84299-K62-C M4; 6 deep B84299-K61 ... B84299-K67 Line Mounting height Type B84299-K61-C B84299-K62-C Length l 65 mm 75 mm B84299-K63 M4; 8 deep Line ) Ground terminal for shielding braid or fixing stud for cable clamp M4 Mounting height 214 03/01 2-Line Filters for Installations and Systems Dimensional drawings B84299-K64-C M4; 6 deep B84299-K61 ... B84299-K67 Line B84299-K65 M4; 6 deep ) Ground terminal for shielding braid or fixing stud for cable clamp M4 215 03/01 Mounting height Line Mounting height 2-Line Filters for Installations and Systems Dimensional drawing B84299-K66, B84299-K67 M5; 7 deep B84299-K61 ... B84299-K67 AWG 12 or 10 Type B84299-K66 B84299-K67 Litz wire AWG 12; 3,44 mm2 AWG 10; 5,37 mm2 Length l (mm) a b 300 (line) 240 (line) 800 800 ) Ground terminal for shielding braid or fixing stud for cable clamp M4 216 03/01 Mounting height Line 2-Line Filters for Installations and Systems Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84299-K61-C 100 SSB0323-3 B84299-K61 ... B84299-K67 B84299-K62-C 100 SSB0324-B e dB 80 e dB 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f 0 10 4 10 5 10 6 10 7 Hz 10 8 f B84299-K63 100 SSB0325-J B84299-K64-C 100 SSB0326-S e dB 80 e dB 80 60 60 40 40 20 20 0 10 4 10 5 10 6 Hz f 10 7 0 10 4 10 5 10 6 Hz f 10 7 217 03/01 2-Line Filters for Installations and Systems Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84299-K65 100 SSB0327-1 B84299-K61 ... B84299-K67 B84299-K66 100 SSB0328-9 e dB 80 e dB 80 60 60 40 40 20 20 0 10 4 10 5 10 6 Hz f 10 7 0 10 4 10 5 10 6 .Hz f 10 7 B84299-K67 100 SSB0329-H e dB 80 60 40 20 0 10 4 10 5 10 6 Hz f 10 7 218 03/01 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 Munchen, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfaltigung, Veroffentlichung, Verbreitung und Verwertung dieser Broschure und ihres Inhalts ohne ausdruckliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschure werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen fur Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschure ersetzt die vorige Ausgabe. Fragen uber Technik, Preise und Liefermoglichkeiten richten Sie bitte an den Ihnen nachstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente konnen aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskunfte daruber bitten wir unter Angabe des betreffenden Typs ebenfalls uber die zustandige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS' prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1 |
Price & Availability of B84299-K67
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |