Current Transducer LB 100-S/SP3 For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). IPN = 100 A Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd @ 100 A max @ 200 A max 100 0 .. 200 RM min RM max 0 0 100 1 : 1000 15 20 + IS 5 1) 85 30 A A W W mA V mA kV Features * Closed loop (compensated) current transducer using the Hall effect * Insulated plastic case recognized according to UL 94-V0. Special features * VC = 15 ( 5 %) V * Better zero crossing performance * TA = + 10C .. + 50C * Potted. Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn Advantages * Excellent accuracy * Very good linearity * Low temperature drift * Optimized response time * Wide frequency bandwidth * No insertion losses * High immunity to external interference Accuracy - Dynamic performance data e X L Accuracy @ IPN, TA = 25C Linearity Offset current @ IP = 0, TA = 25C Thermal drift of IO + 10C .. + 50C Response time 2) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) Zero crossing distortion 0.5 < 0.1 Max 0.4 0.35 0.4 <1 > 50 DC .. 150 negligeable Typ % % mA mA s A/s kHz IO IOT tr di/dt f * Current overload capability. Applications * AC variable speed drives and servo motor drives General data TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 50C Mass Standards 3) + 10 .. + 50 - 25 .. + 85 25 180 EN 50178 C C W g * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Switched Mode Power Supplies (SMPS) * Power supplies for welding applications * HVDC transmisions. Notes : 1) 2) 3) Between primary and secondary. With a di/dt of 100 A/s A list of corresponding tests is available. 990723/1 Dimensions LB 100-S/SP3 (in mm. 1 mm = 0.0394 inch) Front view Left view Secondary terminals Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V Connection Top view Mechanical characteristics * General tolerance * Fastening * Primary through-hole * Connection of secondary 0.3 mm 4 holes AE 4.3 mm AE 15 mm Faston 6.3 x 0.8 mm Remarks * IS is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed 70C. * Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. |
Price & Availability of LB100-SSP3
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |