If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Linear Power Supplies Data Sheet Features * RoHS lead-free solder and lead-solder-exempted products are available * Worldwide AC Input Capabilities: 100/120/220/230/240 VAC * 0.05% Output Regulation * Low Output Ripple * UL, CSA, and TUV Approvals * Mean Time Before Failure (MTBF) in Excess of 300,000 Hours * CE marked to Low Voltage Directive * 100% Burn-In * 2 Year Warranty * Overvoltage Protection (OVP) Standard on 5V Single Outputs, Optional for other outputs under 48V DC power. The Linear power supplies are approved to domestic and international regulatory standards, and are CE Marked to the Low Voltage Directive (LVD). Description Power-One produces the industry's broadest selection of Linear power supplies with output voltages from 5 volts through 250 volts. Rugged technology and proven design merge to create quiet, highly-regulated, dependable Overvoltage Protection Options OVERVOLTAGE PROTECTION OPTIONS These optional overvoltage protection modules are offered for use with Power-One's Linear power supplies. Each is user adjustable from 6.4V to 34V. OVP-12 DUAL OUTPUT TRIPLE OUTPUT PEAK CURRENT MODELS NOTE: OVP SELECTION GUIDE MODEL CASE SIZE OVP MODULES REQUIRED SINGLE OUTPUT B,C,N,D E,F AA,B,BB,CC E AA,BAA,D CBB, 131 DBB,DCC N,BAA,CBB 131, CP340-A CP510-A (1) OVP-12 (1) OVP-24 (1) OVP-12 protects both outputs (1) OVP-24 protects both outputs (1) OVP-12 protects both 12V through 15V outputs (1) OVP-12 protects any output not provided with built-in OVP Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48V through 250V models. OVP-24 Ordering Information: To order a model with RoHS lead solder exemption compliance, no RoHS suffix character is required to be added to the part number. To order a model that is RoHS compliant for all six substances, add "G" as the last character of the part number. SEP 26, 2006 revised to MAR 06, 2007 Page 1 of 9 www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* 5Vout 5 5 5 5 5 5 5 5 5 1.5 3 6 9 12 18 25 35 50 0.9 1.7 3.4 5.1 6.8 10.2 16 0.9 1.5 3 4.5 6 9 15 0.5 1.2 2.4 3.6 4.8 7.2 12 0.5 1 2 3 4 6 10 0.5 1 3 4 HAA5-1.5/OVP-A HB5-3/OVP-A HC5-6/OVP-A HN5-9/OVP-A HD5-12/OVP-A HE5-18/OVP-A F5-25/OVP-A G5-35/OVP-A CP197-A HA15-0.9-A HB12-1.7-A HC12-3.4-A HN12-5.1-A HD12-6.8-A HE12-10.2-A F15-15-A HA15-0.9-A HB15-1.5-A HC15-3-A HN15-4.5-A HD15-6-A HE15-9-A F15-15-A HA24-0.5-A HB24-1.2-A HC24-2.4-A HN24-3.6-A HD24-4.8-A HE24-7.2-A F24-12-A HA24-0.5-A HB28-1-A HC28-2-A HN28-3-A HD28-4-A HE28-6-A F24-12-A HB48-0.5-A HC48-1-A HD48-3-A HE48-4-A B B C N D E F F F B B C N D E F B B C N D E F B B C N D E F B B C N D E F B C D E C C C C C C C C, D, H C C C C C C, D, H A A, C A, C A, C A, C A, C A, C, D, H A, C, D, H A, C, D Max Amps Model Input 100 to 264 VAC Case Type Additional Features & Notes Case Type AA B BAA BB C CBB CC CP131 D DBB DCC E F N Dimensions (Inches) 6.50 x 4.00 x 2.10 4.87 x 4.00 x 2.10 10.25 x 4.00 x 2.95 7.00 x 4.87 x 2.95 5.62 x 4.87 x 2.95 11.00 x 4.87 x 3.28 9.38 x 4.87 x 3.28 11.00 x 4.87 x 3.28 9.00 x 4.87 x 3.28 14.25 x 4.87 x 3.38 15.00 x 4.88 x 4.55 14.00 x 4.87 x 3.53 16.75 x 4.88 x 5.00 7.00 x 4.87 x 3.28 CP510-A 8.25 x 4.87 x 3.28 12 to 15Vout 12 12 12 12 12 12 12 15* 15 15 15 15 15 15* C C C C C C, D, H Case Type AA B BAA BB C CBB CC CP131 D Dimensions (Millimeters) 165.10 x 101.60 x 53.34 123.70 x 101.60 x 53.34 260.35 x 101.60 x 74.93 177.80 x 123.70 x 74.93 142.75 x 123.70 x 74.93 279.40 x 123.70 x 83.31 238.25 x 123.70 x 83.31 279.40 x 123.70 x 83.31 228.60 x 123.70 x 83.31 361.95 x 123.70 x 85.85 381.00 x 123.95 x 115.57 355.60 x 123.70 x 89.66 425.50 x 123.95 x 127.00 177.80 x 123.70 x 83.31 24 to 28Vout 24 24 24 24 24 24 24 28* 28 28 28 28 28 28* C C C C C C, D, H CP510-A 209.55 x 123.70 x 83.31 DBB DCC E F N 48Vout 48 48 48 48 (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. * May require jumpering or potentiometer adjustment. SEP 26, 2006 revised to MAR 06, 2007 Page 2 of 9 www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* 5V to 15Vout +5, -5 +5, -5 +5, -5 +5, +12 +5, +12 5, 12 to 15 5, 12 to 15 5, 12 to 15 +12, -5* +12, -5* +12, -12 +12, -12 +12, -12 +12, -12 +12, -12* +12, -15* +12, -15* +12, -15* +12, -15* +15, -5* +15, -5* +15, -12* +15, -12* +15, -12* 15, -12* 1.5, 1.5 3, 3 6, 6 2, 4 6, 2.5 2, 0.5 3, 1.25 6, 2.5 1, 0.4 1.7, 0.7 0.4, 0.4 1, 1 1.7, 1.7 3.4, 3.4 5, 5 1, 0.8 1.7, 1.5 3.4, 3 5, 5 0.8, 0.4 1.5, 0.7 0.8, 1 1.5, 1.7 3, 3.4 5, 5 HAA5-1.5/OVP-A HBB5-3/OVP-A HCC5-6/OVP-A CP323-A CP510-A HAA512-A HBB512-A HCC512-A HAA15-0.8-A HBB15-1.5-A HAD12-0.4-A HAA15-0.8-A HBB15-1.5-A HCC15-3-A HDD15-5-A HAA15-0.8-A HBB15-1.5-A HCC15-3-A HDD15-5-A HAA15-0.8-A HBB15-1.5-A HAA15-0.8-A HBB15-1.5-A HCC15-3-A HDD15-5-A AA BB CC N CP510-A AA BB CC AA BB B AA BB CC E AA BB CC E AA BB AA BB CC E A A A, C A, E A A A, C A, C C C B C C C C C C C C C C C C C C Case Type AA B BAA BB C CBB CC CP131 D DBB DCC E F N Dimensions (Inches) 6.50 x 4.00 x 2.10 4.87 x 4.00 x 2.10 10.25 x 4.00 x 2.95 7.00 x 4.87 x 2.95 5.62 x 4.87 x 2.95 11.00 x 4.87 x 3.28 9.38 x 4.87 x 3.28 11.00 x 4.87 x 3.28 9.00 x 4.87 x 3.28 14.25 x 4.87 x 3.38 15.00 x 4.88 x 4.55 14.00 x 4.87 x 3.53 16.75 x 4.88 x 5.00 7.00 x 4.87 x 3.28 Max Amps Model Input 100 to 264 VAC Case Type Additional Features & Notes CP510-A 8.25 x 4.87 x 3.28 Case Type AA B BAA BB C CBB CC CP131 D DBB DCC E F N Dimensions (Millimeters) 165.10 x 101.60 x 53.34 123.70 x 101.60 x 53.34 260.35 x 101.60 x 74.93 177.80 x 123.70 x 74.93 142.75 x 123.70 x 74.93 279.40 x 123.70 x 83.31 238.25 x 123.70 x 83.31 279.40 x 123.70 x 83.31 228.60 x 123.70 x 83.31 361.95 x 123.70 x 85.85 381.00 x 123.95 x 115.57 355.60 x 123.70 x 89.66 425.50 x 123.95 x 127.00 177.80 x 123.70 x 83.31 CP510-A 209.55 x 123.70 x 83.31 15V to 24Vout +15, -15 +15, -15 +15, -15* +15, -15* +15, -15 +24, -24 +24, -24 +24, -24 0.4, 0.4 0.8, 0.8 1.5, 1.5 3, 3 5, 5 0.6, 0.6 1.2, 1.2 2.4, 2.4 HAD15-0.4-A HAA15-0.8-A HBB15-1.5-A HCC15-3-A HDD15-5-A HAA24-0.6-A HBB24-1.2-A HCC24-2.4-A B AA BB CC E AA BB CC C B C C C C * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow or shaded are not recommended for new designs. (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. SEP 26, 2006 revised to MAR 06, 2007 Page 3 of 9 www.power-one.com Linear Power Supplies Data Sheet Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Vout* +5, -5, 24* +5, +12, -5* 5, +12, -5* +5, +12, -5* +5, +12, -5 5, +12, -5* 5, +12, -5* 5, +12, -5* 5, +12, -12 5, +12, -12 +5, +12, -12 5, +12, -12 +5, +12, -12 5, +12, -12 5, +12, -12 5, +12, -12 5, +12, -15* 5, +12, -15* +5, +12, -15* 5, +12, -15 5, +12, -15 5, +12, -15* 5, +12, -15 5, -12, 24 5, +15, -5* 5, +15, -5* +5, +15, -5* 5, +15, -5* 5, +15, -5* 5, +15, -5* 5, +15, -12* 5, +15, -12* +5, +15, -12* 5, +15, -12 5, +15, -12 5, +15, -12* 5, +15, -12 5, +15, -15* 5, +15, -15* +5, +15, -15* 5, +15, -15 5, +15, -15 5, +15, -15* 5, +15, -15 Max Amps 6, 1.2, 3.5 2, 0.4, 0.4 3, 1, 0.4 6, 1, 0.4 6, 5, 0.25 6, 1.7, 0.7 8, 1.7, 0.7 12, 1.7, 0.7 2, 0.4, 0.4 3, 1, 1 6, 1, 1 6, 1.7, 1.7 6, 5, 0.5 8, 1.7, 1.7 12, 1.7, 1.7 12, 3.4, 3.4 2, 0.4, 0.4 3, 1, 0.8 6, 1, 1 6, 1.7, 1.5 8, 1.7, 1.5 12, 1.7, 1.5 12, 3.4, 3 6, 1.2, 3.5 2, 0.4, 0.4 3, 0.8, 0.4 6, 1, 0.4 6, 1.5, 0.7 8, 1.5, 0.7 12, 1.5, 0.7 2, 0.4, 0.4 3, 0.8, 1 6, 1, 1 6, 1.5, 1.7 8, 1.5, 1.7 12, 1.5, 1.7 12, 3, 3.4 2, 0.4, 0.4 3, 0.8, 0.8 6, 1, 1 6, 1.5, 1.5 8, 1.5, 1.5 12, 1.5, 1.5 12, 3, 3 Model Input 100 to 264 VAC CP379-A HTAA-16W-A HBAA-40W-A HCAA-60W-A CP498-A HCBB-75W-A CP131-A HDBB-105W-A HTAA-16W-A HBAA-40W-A HCAA-60W-A HCBB-75W-A CP498-A CP131-A HDBB-105W-A HDCC-150W-A HTAA-16W-A HBAA-40W-A HCAA-60W-A HCBB-75W-A CP131-A HDBB-105W-A HDCC-150W-A CP379-A HTAA-16W-A HBAA-40W-A HCAA-60W-A HCBB-75W-A CP131-A HDBB-105W-A HTAA-16W-A HBAA-40W-A HCAA-60W-A HCBB-75W-A CP131-A HDBB-105W-A HDCC-150W-A HTAA-16W-A HBAA-40W-A HCAA-60W-A HCBB-75W-A CP131-A HDBB-105W-A HDCC-150W-A Case Type CP131 AA BAA D CP131 CBB CP131 DBB AA BAA D CBB CP131 CP131 DBB DCC AA BAA D CBB CP131 DBB DCC CP131 AA BAA D CBB CP131 DBB AA BAA D CBB CP131 DBB DCC AA BAA D CBB CP131 DBB DCC Additional Features & Notes A, C, F, G A A, C A, C A, C, F C A, C A, C A A, C A, C C A, C, F A, C C A, C A A, C A, C C A, C C A, C A, C, F, G A A, C A, C C A, C A A, C A, C C A, C C A, C A A, C A, C C A, C C A, C Triple Output Models, 5V to 24Vout Case Type AA B BAA BB C CBB CC CP131 D DBB DCC E F N Dimensions (Inches) 6.50 x 4.00 x 2.10 4.87 x 4.00 x 2.10 10.25 x 4.00 x 2.95 7.00 x 4.87 x 2.95 5.62 x 4.87 x 2.95 11.00 x 4.87 x 3.28 9.38 x 4.87 x 3.28 11.00 x 4.87 x 3.28 9.00 x 4.87 x 3.28 14.25 x 4.87 x 3.38 15.00 x 4.88 x 4.55 14.00 x 4.87 x 3.53 16.75 x 4.88 x 5.00 7.00 x 4.87 x 3.28 CP510-A 8.25 x 4.87 x 3.28 Case Type AA B BAA BB C CBB CC CP131 D DBB DCC E F N Dimensions (Millimeters) 165.10 x 101.60 x 53.34 123.70 x 101.60 x 53.34 260.35 x 101.60 x 74.93 177.80 x 123.70 x 74.93 142.75 x 123.70 x 74.93 279.40 x 123.70 x 83.31 238.25 x 123.70 x 83.31 279.40 x 123.70 x 83.31 228.60 x 123.70 x 83.31 361.95 x 123.70 x 85.85 381.00 x 123.95 x 115.57 355.60 x 123.70 x 89.66 425.50 x 123.95 x 127.00 177.80 x 123.70 x 83.31 CP510-A 209.55 x 123.70 x 83.31 (See Additional Features Column) A Overvoltage protection, set at 6.2 V 0.4 V. B Non-adjustable 3-terminal regulator. C Remote sense provided. D With output inhibit and parallel operation master/slave capability. E With output inhibit. F Adjustable 3-terminal regulator. G Can be made into an isolated output by removing jumper W1. H Model requires 100 LFM forced-air cooling above 75% of rated output power at 50 degrees C. Quad Output Models, 5V to 24Vout 5, +12, -5, +24* 5, +12, -12, +24 6, 1, 0.5, 2.4 6, 1, 1, 2.4 CP503-A CP503-A CP131 CP131 A, H A, H * May require jumpering or potentiometer adjustment. Model numbers highlighted in yellow or shaded are not recommended for new designs. SEP 26, 2006 revised to MAR 06, 2007 Page 4 of 9 www.power-one.com Linear Power Supplies Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC (Note 1, 2) Input Frequency Line Regulation Jumper selectable, shipped factory configured for 120VAC operation. All models must be externally fused for proper operation. Fuse ratings are marked on each unit. Consult factory for each unit's fuse requirements. AC input. Output voltage charge for a 10% line change: F case models. HAD12, HAD15. Outputs with adjustable three terminal regulators. All other models. 100 VAC Tap 120 VAC Tap 220 VAC Tap 240 VAC Tap 87 104 191 209 47 -0.01 -1.0 -0.5 -0.05 100 120 220 240 110 132 242 264 63 +0.01 +1.0 +0.5 +0.05 VAC Hz % NOTES: 1) Derate output current 10% for 50Hz operation. 2) Input voltage tolerance for 230VAC operation is +15%, -10%. Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Minimum output adjustment range (Note 1). -5 +5 % 5 volt outputs. 45 12 volt and 15 volt outputs. 55 % 24 volt and higher outputs. 60 F case models. 3.0 mVPK-PK Ripple and Noise 5 volt, 12 volt, and 15 volt models. 5.0 mVPK-PK (Note 2) All three terminal regulator outputs. 0.2 %PK-PK 24 volt through 250 volt models. 3.0mVPK-PK plus 0.02% of output voltage, max Load Regulation Output change for a 50% load change: F case models. -0.02 +0.02 HAD12, HAD15. -1 +1 % Outputs with adjustable three terminal regulators. -0.5 +0.5 All other models. -0.05 +0.05 Transient Response Recovery time, to within 1% of initial set point due to a 50% load change. 50 s NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within 5% of nominal voltage. Locate the "Vadj" potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3-terminal regulator outputs are not adjustable. 2) Full load, 20MHz bandwidth. Output Adjustment Efficiency Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference Leakage Current UL60950 3rd Edition. CSA 60950 3rd Edition. EN60950 3rd Edition. IEC60950 3rd Edition Input to output. Input to ground. FCC CFR title 47 Part 15 Sub-Part B - conducted. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated. Per EN60950 Approved 3750 3750 VRMS Compatible with system compliance to Level B. (264VAC) 23 50 A Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Remote Sense Overcurrent/Short Circuit Protection Master/Slave Operation Provided on 5 volt output units where indicated. Other outputs may use optional overvoltage protectors OVP-12 and OVP-24. Total voltage compensation for cable losses with respect to the main output. Provided on models where indicated. Automatic current limit/foldback. Rated as a percentage of output power. 5.8 6.6 250 V mV % 115 120 140 For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes. Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead solder exemption RoHS compliant for all six substances No RoHS suffix character required. Add "G" as the last character of the part number. SEP 26, 2006 revised to MAR 06, 2007 Page 5 of 9 www.power-one.com Linear Power Supplies Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Operating Temperature Storage Temperature Temperature Coefficient Shock Vibration Relative Humidity Derate output power linearly above 50C by 3% per C. At 100% load At 40% load 0 -40 0C to 50C (after 15 minute warm-up). 24 hours after warm-up. Operating. Random vibration from 10 Hz to 2 kHz, 3 axis. Non-Condensing. 0.1 -0.3 5 50 70 85 0.3 +0.3 20 6.15 95 C C C %/C % GPK GRMS %RH SEP 26, 2006 revised to MAR 06, 2007 Page 6 of 9 www.power-one.com Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 7 of 9 www.power-one.com Linear Power Supplies Data Sheet SEP 26, 2006 revised to MAR 06, 2007 Page 8 of 9 www.power-one.com Linear Power Supplies Data Sheet NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. SEP 26, 2006 revised to MAR 06, 2007 Page 9 of 9 www.power-one.com |
Price & Availability of OVP-24
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |