|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Features 2:1 Wide Input Voltage Range 20 Watts Output Power 1.6kVDC Isolation ULCertified Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x40.6x10.2mm Package Efficiency to 86% POWERLINE DC/DC-Converter Selection Guide 12V, 24V and 48V Input Types Part Number Input Range VDC 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 Output Voltage VDC 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 5 12 15 5 12 15 5 12 15 3.3 / 12 3.3 / 15 5 / 12 5 / 15 3.3 / 12 3.3 / 15 5 / 12 5 / 15 3.3 / 12 3.3 / 15 5 / 12 5 / 15 Output Current mA 4000 4000 1670 1330 4000 4000 1670 1330 4000 4000 1670 1330 2000 833 666 2000 833 666 2000 833 666 3000 / 300 3000 / 250 2000 / 300 2000 / 250 3000 / 300 3000 / 250 2000 / 300 2000 / 250 3000 / 300 3000 / 250 2000 / 300 2000 / 250 Input (4) Efficiency(5) Capacitive(6) Current Load max. mA % F 1507 2193 2136 2136 743 1082 1054 1054 367 543 527 527 2193 2136 2136 1082 1054 1041 541 514 508 1926 1959 1885 1919 950 967 931 947 468 477 459 467 77 80 82 82 78 81 83 83 79 82 83 83 80 82 82 81 83 84 81 85 86 78 78 80 80 79 79 81 81 80 80 82 82 13000 6800 2200 755 13000 6800 2200 755 13000 6800 2200 755 3400 680 450 3400 680 450 3400 680 450 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 4700 /220 RP20S_D_TE Series 20 Watt Single, Dual & Triple Output RP20-123.3SE RP20-1205SE RP20-1212SE RP20-1215SE RP20-243.3SE RP20-2405SE RP20-2412SE RP20-2415SE RP20-483.3SE RP20-4805SE RP20-4812SE RP20-4815SE RP20-1205DE RP20-1212DE RP20-1215DE RP20-2405DE RP20-2412DE RP20-2415DE RP20-4805DE RP20-4812DE RP20-4815DE RP20-123.312TE RP20-123.315TE RP20-120512TE RP20-120515TE RP20-243.312TE RP20-243.315TE RP20-240512TE RP20-240515TE RP20-483.312TE RP20-483.315TE RP20-480512TE RP20-480515TE UL-60950-1 Certified Description The E-Series of DC/DC Converters are fully certified to EN 60950: 2000. The E-series of these DC/DC-converters is designed to meet UL 60950. This makes them ideal for all telecom and safety applications where approved isolation is required. They are also designed to meet UL 1950 and CSA 950 standards (10). www.recom-international.com July-2006 247 POWERLINE DC/DC-Converter RP20-S_D_TE Series RP20-4805SE With Heat Sink 125 100 Derating-Graph (Ambient Temperature) RP20-4805SE 125 100 75 Output Power (%) 50 25 50 60 70 Ambient Temperature Range (C) 0 -40 -25 -10 0 80 90 100 Output Power (%) Natural Convection 75 50 25 Natural Convection 50 60 69 Ambient Temperature Range (C) 0 -40 -25 -10 0 80 90 100 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at Typical Characteristics RP20-4805SE Efficiency VS Input Voltage 85 84 83 82 81 80 79 78 77 76 75 74 85 84 83 82 81 80 78 76 74 70 65 60 RP20-4805SE Efficiency VS Output Load Efficiency (%) Efficiency (%) 36 40 45 50 55 60 65 70 75 0.5 1 1.5 2 2.5 3 2.5 4 Input Voltage (V) Output Load (A) Specifications (typical at nominal input and 25C unless otherwise noted) Input Voltage Range 12V nominal input 24V nominal input 48V nominal input 12V Input 24V Input 48V Input 9-18VDC 18-36VDC 36-75VDC Pi Type 36VDC 50VDC 100VDC 25mAp-p DC-DC ON DC-DC OFF Nominal input Single & Dual Triple 3.3V, 5V Auxiliary 20ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 20mA 20W max. 2% 2% 5% 10% continued on next page 248 July-2006 www.recom-international.com Input Filter Input Surge Voltage (100 ms max.) Input Reflected Ripple (nominal Vin and full load) (see Note 3) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see Note 7) ( Positive logic ) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin) Voltage Adjustability POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Minimum Load (see Note 1) Line Regulation (low line, high line at full load) Single (W) Dual (W) Triple 3.3V, 5V Auxiliary Single Dual Triple 3.3V, 5V Auxiliary Dual Triple 3.3V, 5V Auxiliary Single Dual Triple 3.3V, 5V Auxiliary RP20-S_D_TE Series 10% of full load 0.2% 0.5% 1% 5% 0.5% 3% 2% 5% 5% 2% 5% 75mVp-p 100mVp-p 50mVp-p 1% of Vout 0.02%/C max. 3.3V 5V 12V 15V 500s 3.9V 6.2V 15V 18V Hiccup, automatic recovery see Selection Guide" table 1600VDC min. 1 G min. 300pF max. 300kHz typ. UL 1950, EN60950 -40C to +85C(with derating) +100C Natural convection Natural convection with Heat Sink -55C to +105C 10C/Watt 8.24C/Watt MIL-STD-810D 10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Nickel plated copper Non-conductive black plastic Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Level A Level A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 continued on next page Load Regulation (25% to 100% full load) Cross Regulation (see Note 9) Ripple and Noise (20MHz bandwith) Temperature Coefficient Transient Response (25% load step change) Over Voltage Protection Zener diode clamp (only single) Short Circuit Protection Efficiency Isolation Voltage Isolation Resistance Isolation Capacitance Operating Frequency Approved to Safety Standards (see Note 10) Operating Temperature Range Maximum Case Temperature Storage Temperature Range Thermal Impedance (see Note 8) Thermal Shock Vibration Relative Humidity Case Material Base Material Potting Material Conducted Emissions (see Note 11) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity www.recom-international.com July-2006 249 POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Weight Dimensions MTBF (see Note 2) RP20-S_D_TE Series 48g 50.8 x 40.6 x 10.2mm 1928 x 103 hours Notes : 1. The RP20 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Simulated source impedance of 12H. 12H inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control voltage is reference to negative input. 8. Heat sink is optional and P/N: 7G-0011A. Operation temperature range please see curve. 9. Cross regulation: Dual output--Asymmetrical load 25% to 100% full load Triple output - 3.3V / 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load 10.See application notes for EMI-filtering. Package Style and Pinning (mm) 3rd angle projection 50.10 10.20 dia. 1.0 5.6 40.60 Pin Connections Pin # 1 2 4 5 6 7 8 Single +Vin -Vin CTRL No Pin +Vout -Vout Trim Dual +Vin -Vin CTRL +Vout Com -Vout Trim Triple +Vin -Vin CTRL +Auxiliary +3.3V / 5V Com -Auxiliary 45.70 5 17.80 1 2 7 4 10.20 Bottom View 12.70 Pin Pitch Tolerance 0.35 mm 6 5.10 15.20 External Output Trimming 10.20 17.80 8 Output can be externally trimmed by using the method shown below. ( ) for dual output trim 7(7) Trim Up RU 8(8) Trim Down RD 8(8) 6(5) 250 July-2006 www.recom-international.com |
Price & Availability of RP20-4833SE |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |