![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS400K.doc version 3.2 01.12.2003 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: External coil: 23 10 375 375 47 nH Preliminary Specification TFS 400 K 1/5 C dBm -1.9 pF -1.9 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS400K is the minimum of the pass band attenuation amin . The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae . The nominal frequency fN is fixed at 400 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion Loss (reference level) Nominal Frequency Bandwidth 3 dB arel ... fN 500 700 1 kHz ... fN kHz ... fN MHz ... fN 82,5 700 1 13 kHz kHz MHz MHz ae fN BW typ. value 4,5 400,04 dB MHz tolerance / limit max. 6,5 400 dB MHz T.B.D. - Relative Attenuation fN fN fN fN 0,4 28 43 50 dB dB dB dB max. min. min. min. 1 15 27 40 dB dB dB dB Group Delay Ripple fN 82,5 kHz OTR 0,6 20 TCf ** -0,036 C ppm/K s max. 1 s Operating Temperature Range Storage Temperature Range Frequency Inversion Temperature Temperature Coefficient of Frequency -40 C ... + 85 C - 40 C ... + 85C - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. These values have to be confirmed by balanced s-parameter measurement. **) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz). Generated: Checked / Approved: TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS400K.doc version 3.2 01.12.2003 VI TELEFILTER (all dimensions in mm) Preliminary Specification - matching network TFS 400 K 2/5 Construction, pin configuration and 50 5.0 SQ -0.1 7 5 +0.15 400 K R20 1 Date code Pin Pin Pin Pin 1 2 3 4,8 Sym. Output Sym. Output External Coil Package Ground Pin 5 Pin 6 Pin 7 Sym. Input Sym. Input Ground Date code: N P R ... Year + week 2001 2002 2003 3 50 Ohm Test circuit 1 LB-IN L1 6 1 L3 LB-OUT C1 SAW 5 3 4, 7, 8 L5 2 C2 L2 L4 50 Ohm Test circuit 2 LB-IN C1 6 1 C3 LB-OUT L1 SAW 5 3 L3 2 L2 C2 C4 4, 7, 8 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS400K.doc version 3.2 01.12.2003 VI TELEFILTER Stability Characteristics Preliminary Specification TFS 400 K 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to older heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4 Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W : 12 0,3 Po : 4 0,1 Do : 1,5 + 0,1 E : 1,75 0,1 F : 5,5 0,05 G (min) : 0,75 P2 : 2 0,05 P1 : 8 0,1 D1(min) : 1,5 Ao : 5,3 0,1 Bo : 5,3 0,1 CT : 9,5 0,1 Po EMBOSSED CARRIER TAPE Do P2 E Ao F W D1 CT Bo G P1 COVER TAPE W2 Reel (all d imensions in mm): A : 330 12 ,4 + 2 18 ,4 50 13 + 0 ,5 - 0 ,2 A C N W1 : W2 (m ax) : N (m in) C : : W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS400K.doc version 3.2 01.12.2003 VI TELEFILTER Air reflow temperature conditions Preliminary Specification TFS 400 K 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS400K.doc version 3.2 01.12.2003 VI TELEFILTER History Version 1.0 2.0 Reason of Changes Preliminary Specification TFS 400 K 5/5 Name Pfeiffer Dr. Wall Date 12.05.2003 11.06.2003 - Generate development specification. - Modification of electrical data based on TFS400B to support a group delay ripple of 1 s maximum. - Correct reel dimensions. Add 1 dB pass band of 160 kHz. Shift 15 dB limit line to +-500 kHz Shift 27 dB limit line to +-700 kHz Remove values for termination impedances and coupling coil. Add 50 Ohm test circuit configuration. 3.0 Dr. Wall 19.06.2003 3.1 3.2 - Change frequency band for 1 dB pass band and group delay ripple requirement - Change from development specification to preliminary specification - Add preliminary values for termination impedances - Add typical values Dr. Wall Dr. Wall 03.07.2003 01.12.2003 TELEFILTER GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS400K
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |