|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS912.doc version 1.2 02.07.2002 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedances* for input: for output: 23 0 C dBm Filter Specification TFS 912 1/5 190 // -0.15 pF 190 // -0.15 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 912 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the -3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 912,5 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion loss (Reference level) Nominal frequency Centre frequency 2 dB Bandwidth 3 dB Bandwidth Pass band ripple Relative attenuation fN - 117,5 MHz .... fN fN + 117,5 MHz .... fN fN + 257,5 MHz .... fN fN + 302,5 MHz .... fN ae = amin fN fc typ. value 3,85 912,5 54,3 57,7 1.8 dB dB dB dB MHz MHz MHz dB min. min. min. min. dB tolerance/limit max. 5,0 912,5 dB MHz BW BW within 22,5 MHz arel - 812,5 MHz + 257,5 MHz + 302,5 MHz + 587,5 MHz 47,0 50,0 50,0 50,0 min. max. 40,0 30,0 45,0 40,0 45,0 3,0 dB dB dB dB MHz dB Operating temperature range Storage temperature range Temperature Coefficient - 25 C ... + 75 C - 30 C ... + 80 C TC - 72 ppm / K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. Generated: Checked / approved: VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS912.doc version 1.2 02.07.2002 VI TELEFILTER Filter Specification TFS 912 2/5 Construction, pin configuration and 50 - matching network (All dimensions in mm) 7 5 1,78 912 P27 1 3 SQ 3,81 + 0,2 / -0,1 1,78 0,6 0,1 Date code 1,1 Max. 2,54 Pin 1 Pin 2 Pin 3 Pin 4 Input Ground Ground Package Ground Pin 5 Pin 6 Pin 7 Pin 8 Output Ground Ground Package ground Date code: M N P ... Year + week 2000 2001 2002 50 Ohm Test circuit L1 1 5 L2 IN C1 SAW C2 OUT 2,3,4,6,7,8 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS912.doc version 1.2 02.07.2002 VI TELEFILTER Stability Characteristics Filter Specification TFS 912 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to older heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.;for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4 Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do : : : 12 4 1,5 0,3 0,1 + 0,1 Po EMBOSSED CARRIER TAPE Do P2 E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo CT : : 1,75 0,1 5,5 0,05 0,75 2 0,05 8 0,1 1,5 4,3 0,1 4,3 9,5 0,1 0,1 E Ao D1 CT Bo F W G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 : : 330 12,4 + 2,0 18,4 50 13 -+0,5/ -0,2 A C N W2 (max) : N (min) C : : W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS912.doc version 1.2 02.07.2002 VI TELEFILTER Filter Specification TFS 912 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS912.doc version 1.2 02.07.2002 VI TELEFILTER History Version 1.0 1.1 Reason of Changes Filter Specification TFS 912 5/5 Name Dr. Sabah Date 29.08.2001 - Generation of development specification according to customer specification Variation 1.2 (e-mail: 23.11.2001) - Filter specification, - Add of typ. values - add of matching circuit and terminating impedance -Correct of 2 dB pass band Dr. Sabah Dr. Sabah 26.06.2002 02.07.2002 1.2 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS912 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |