OM1805NMM OM1815NMM OM1812NMM HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE REGULATORS APPROVED TO DESC DRAWINGS Three Terminal, Fixed Voltage, 1.5 Amp Precision Positive Regulators In Hermetic Surface Mount Package FEATURES * * * * * * Hermetic Surface Mount Package Output Voltages: +5V, +12V, +15V Output Voltages Set Internally To 1% Built-In Thermal Overload Protection Short Circuit Current Limiting Hi-Rel Screening Available DESCRIPTION These three terminal positive regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to 1% of nominal voltage. Standard voltages are +5V, +12V, and +15V. These units are ideally suited for Military applications where a hermetic surface mount package is required. PART NUMBER DESIGNATOR Standard Military Drawing Number 5962-8778201 NX 5962-8777601 NX 5962-8855301 NX Omnirel Part Number OM1805NMM OM1812NMM OM1815NMM 3.5 4 11 R0 3.5 - 37 OM1805NMM - OM1815NMM ABSOLUTE MAXIMUM RATINGS @ 25C Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55C to + 150C Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to + 150C Typical Power/Thermal Charateristics: Rated Power @ 25 C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W Thermal Resistance JC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5C/W JA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120C/W a ELECTRICAL CHARACTERISTICS 5 Volt Parameter Output Voltage Symbol VOUT VIN = 10V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 4.92 Max. 5.08 5.15 Unit V V Test Conditions TA = 25C VIN = 7.5V to 20V IO = 5mA to 1.0A, P < 15 W * 4.85 Line Regulation (Note 1) (Note 4) VRLINE VIN = 7.5V to 20V 5 mV mV mV mV mV mV mV mV mA mA mA * VIN = 8.0V to 12V 12 4 * Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0Amp IO = 250mA to 750 mA 10 12 * * 25 6 15 6 Standby Current Drain ISCD ISCD (Line) ISCD (Load) VDO IO (pk) IDS VIN VOUT NO VOUT t TA = 25C, VOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V 1.5 IO = 5mA to 1000mA VIN = 7.5V to 20V Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection * * * 6.5 0.8 0.5 mA 2.5 3.3 1.2 V A A A dB dB * f =120 Hz, VIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 68 2.8 * 60 40 Output Noise Voltage (Note 3) Long Term Stability V/V RMS 75 mV 3.5 (Note 3) Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. 3.5 - 38 OM1805NMM - OM1815NMM ELECTRICAL CHARACTERISTICS 12 Volt Parameter Output Voltage Symbol VOUT VIN = 19V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 11.88 Max. 12.12 12.36 Unit V V Test Conditions TA = 25C VIN = 14.5V to 27V IO = 5mA to 1.0 A, P < 15W * 11.64 Line Regulation (Note 1) (Note 4) VRLINE VIN = 14.5V to 27V 18 mV mV mV mV mV mV mV mV mA mA mA * VIN = 16V to 22V 50 9 * Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0 Amp IO = 250mA to 750 mA 30 32 * * 60 20 40 6.0 Standby Current Drain ISCD ISCD (Line) ISCD (Load) VDO IO (pk) IDS VIN VOUT NO VOUT t VOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V IO = 5mA to 1000mA VIN = 15V to 30V Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection * * * * 1.5 6.5 0.8 0.5 mA 2.5 3.3 1.2 V A A A dB dB * f =120 Hz, VIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 61 2.8 * 54 40 Output Noise Voltage (Note 3) Long Term Stability (Note 3) V/V RMS 120 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. MECHANICAL OUTLINE .140 .015 .075 .140 1 CONNECTION .075 .140 2 .157 .030 MIN. Pin 1 Input Pin 2 Output Pin 3 Ground 3.5 3 .415 .062 .375 3.5 - 39 OM1805NMM - OM1815NMM ELECTRICAL CHARACTERISTICS 15 Volt Parameter Output Voltage Symbol VOUT VIN = 23V, Io = 500mA, -55C TA 125C (unless otherwise specified) Min. 14.8 Max. 15.2 15.4 Unit V V Test Conditions TA = 25C VIN = 18.5V to 30V IO = 5mA to 1.0 A, P < 15W * 14.6 Line Regulation (Note 1) (Note 4) VRLINE VIN = 17.5V to 30V 20 mV mV mV mV mV mV mV mV mA mA mA * VIN = 20V to 26V 50 15 * Load Regulation (Note 1) VRLOAD IO = 5mA to 1.5 Amp IO = 5mA to 1.0 Amp IO = 250mA to 750 mA 25 35 * * 75 21 45 6.0 Standby Current Drain ISCD ISCD (Line) ISCD (Load) VDO IO (pk) IDS VIN VOUT NO VOUT t TA = 25C, VOUT = 100mV, IO = 1.0A TA = 25C VIN = 35V 1.5 IO = 5mA to 1000mA VIN = 18.5V to 30V Standby Current Drain Change With Line Standby Current Drain Change With Load Dropout Voltage Peak Output Current Short Circuit Current (Note 2) Ripple Rejection * * * 6.5 0.8 0.5 mA 2.5 3.3 1.2 V A A A dB dB * f =120 Hz, VIN = 10V (Note 3) TA = 25C, f =10 Hz to 100KHz TA = 25C, t = 1000 hrs. 54 2.8 * 52 40 Output Noise Voltage (Note 3) Long Term Stability (Note 3) V/V RMS 150 mV Notes: 1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately. 2. Short Circuit protection is only assured up to VIN = 35V. 3. If not tested, shall be guaranteed to the specified limits. The * denotes the specifications which apply over the full operating temperature range. 4. Minimum load current for full line regulation = 5.0 mA. TYPICAL PERFORMANCE CHARACTERISTICS 3.5 3 Tj = -55C 2.5 100 2 2.5 1.5 2 Tj = 25C IOUT = 500mA Ripple Rejection (dB) IOUT = 1A 80 VOUT = 5V Output Current (A) 3.5 60 1.5 1 Tj = 150C 1 IOUT = 0A 40 VIN - V = 8VDC +3.5Vrms IOUT = 1A Tj = 25C 0.5 VOUT = 100MV 0.5 0 0 20 VOUT = 100mV 5 10 15 20 25 30 35 0 -75-50 -25 0 2 5 5 0 7 5 100 125150 0 10 100 1k 10k Input To Output Differential (V) Junction Temperature (C) Frequency (Hz) |
Price & Availability of OM1815NMM
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |