Series FS Output to 20A 280 Vac DC Control Part Number FS24R10-06 FS24D10-06 FS24D10 FS24D20-06 Description 10A, 280 Vac 10A, 280 Vac 10A, 280 Vac 20A, 280 Vac Part Number Explanation FS 24 R 10 -06 FEATURES/BENEFITS * Miniature size package * Designed for medium-power applications * Faston or PCB terminals available * Tight zero-cross window for low EMI * Excellent thermal performance * High immunity to surges DESCRIPTION The Series FS relays are designed for medium-power loads. The design incorporates a triac output. The Series FS relays utilize optical isolation to protect the control from load transients. The FS compact package is available with faston or PCB terminals. Its compact size makes it ideal for designs where space is limited. The Series FS relays have excellent thermal performance. APPLICATIONS * Heating control * Motor control * Uninterruptible power supplies * Light dimmers * Industrial and process control * On/Off controls of medium-power AC equipment * Electromechanical line relay replacement APPROVALS All models are UL recognized. UL File Number E128555. NOTES 1) Line Voltage (nominal): 24 = 240 Vac 2) Switch Type: R = Random turn-on; D = Zero-cross turn-on; 3) Feature: -06 = Faston terminals MECHANICAL SPECIFICATION .19x.03 (4.8x0.8) .25x.03 (6.35x0.8) .39 (10) .46 (11.6) .32 (8) .98 (25) .59 (15) .08 (2) 1.4 (35.5) 1.18 (30) .5 (12.7) .25 (6.4) .34 (8.6) WEIGHT: 3.2 oz. (90g) -4 2 .83 (21) .16 (4) .83 (21) Figure 1a -- FS relays except FS24D10 O 0.5 (1.32) .24 (6) .83 (21) .08 (2) 1.4 (35.5) 1.18 (30) .5 (12.7) .2 (5.06) .83 (21) 1 +3 (c) 2003 TELEDYNE RELAYS +3 -4 .83 (21) Figure 1b -- FS24D10 Figure 2 -- FS relays (800) 284-7007 * www.teledynerelays.com FS 1 FS\032003\Q1 1 .59 (15) WEIGHT: 3.2 oz. (90g) EQUIVALENT CIRCUIT .16 (4) .3 (7.62) 3+ R 1~ 2 4- ZERO CROSS 2~ Series FS INPUT (CONTROL) SPECIFICATION Min Control Range FS24D Input Current Range FS24R FS24D Must Turn-Off Voltage All relays Input Resistance (Typical) All relays Reverse Voltage Protection All relays 30 V Zero Cross Window (Typical) FS24 FS24 OUTPUT (LOAD) SPECIFICATION Input Type Operating Range All relays Peak Voltage All relays Load Current Range (Resistive) 10A output current 20A output current Inductive Load Current 10A output current 20A output current 2.5 4 Arms Arms Maximum di/dt (Non-Repetitive) All relays Maximum Surge Current Rating (Non-Repetitive) 10A output current 20A output current On-State Voltage Drop All relays output current 1.3 V 120 200 A A Operating Frequency Range All relays I2t for Match Fusing (<8.3ms) 10A output current 20A output current .005 .005 72 200 A2S A2S 0.1 440 Hz 50 A/s .005 .005 10 20 Arms Arms Off-State dv/dt All relays 500 V/s 600 Vpeak 12 280 Vrms Turn-On Time (60 Hz) FS24R FS24D Turn-Off Time (60 Hz) All relays 8.3 ms 0.1 8.3 ms ms Min Max Units Off-State Leakage Current (60Hz) All relays 3 mA R D NA 12 Vac 1000 Ohms OUTPUT (LOAD) SPECIFICATION (Continued) Min Max Units 1 Vdc 2 3 30 30 mAdc mAdc 4 30 Vdc Input Current (mA) CONTROL CHARACTERISTIC Units Vdc 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Max 30 FS24R 3 Control Voltage (V) Figure 3 -- FS relays FS 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2003 TELEDYNE RELAYS FS\032003\Q1 Series FS ENVIRONMENTAL SPECIFICATION Min Operating Temperature Storage Temperature Input-Output Isolation Output-Case Isolation -40 -40 4000 2500 Max 100 100 Units C Vrms Vrms Apeak 150 SURGE CURRENT C 100 Non-Repetitive 50 Repetitive with initial Tj = 70C 0 0.01 0.1 t (s) 1 10 Figure 4a -- All 10A FS relays output current NOTES: 1. External snubber is recommended when switching inductive loads. 2. Electrical specifications at 25C unless otherwise specified. 3. For 800Hz applications, contact factory. 4. For additional/custom options, contact factory. 200 Overload Current (A) 180 160 140 120 100 80 60 40 20 0 1 10 100 1000 Number of Cycles Figure 4b -- FS24D20-06 output current THERMAL CHARACTERISTICS 13 12 0C/W 2C/W /W 4 C 11 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 0 10 20 30 40 50 60 70 80 90 100 110 120 125 NO HE AT SIN K Load Current (Arms) Ambient Temperature (C) Figure 5a -- All 10A FS relays output current 35 70 30 Power Dissipation (W) 25 20 4 C/ W 90 15 10 5 NO H EAT S IN K 0 0 5 10 15 20 0 10 20 30 40 50 60 70 80 90 100 110 120 125 Load Current (Arms) Ambient Temperature (C) Figure 5b -- FS24D20-06 output current (c) 2003 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com FS 3 FS\032003\Q1 Max Case Temperature (C) 2 C/ W 80 100C Max Case Temperature (C) Power Dissipation (W) 90C /W 0C W C/ 1 W C/ 2 1. W C/ 5 1. |
Price & Availability of FS24R10-06
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |