|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Safety Relays Expansion Units Minotaur MSR19E Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Cat. 4 per EN 954-1 (ISO 13849-1) CE marked for all applicable directives and cULus 24V AC/DC -20%, +10% 120V AC -15%, +10% 240V AC -15%, +10% 3.6W 6.1VA, 5.7W 1 N.C. or 2 N.C. 0.5s 100 Automatic 8 N.O. Safety; 2 N.C. Auxiliary C300, AC-15 0.75A/240V AC, 1.5A/120V AC Q300, DC-13; 2A/24V DC 1x8A, 2x7A,4x6A,6x5A,8x4.5A 20s reset time 1.6 slow blow 24V AC/DC, 20mA 20ms Red = Input Short Green = Power Green = K1 Green = K2 3000V C in accordance with VDE 0110 2 -25C to +55C (-13F to +131F) 95% RH IP40, (NEMA 1), DIN 0470 IP20, DIN 0470 1 x 2.5mm2 (14AWG) 0.8Nm (7lbin) Red Polyester PBT 35mm DIN rail 630g (1.4lbs) 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations 10,000,000 operations 0.75mm (0.30in) peak, 10-55Hz 10g, 11ms half sine Category Approvals Power Supply AZ1 and AZ2 AZ1 AZ2 Power Consump. 24V AC/DC 120V and 240V AC Safety Inputs Input Simultaneity Description The Minotaur MSR19E is a monitoring safety expansion relay unit with dual channel input. It is designed to be operated as an "extension" of a "master" safety relay. When wired properly, the outputs of the MSR19E will mimic the outputs of the master relay. With its 8 safety outputs, the MSR19E can be used to drive multiple safety circuits. Two auxiliary normally closed contacts are available to provide indication of the status of the MSR19E, which would reflect the status of the master safety relay. Maximum Input Resistance Reset Outputs Output Utilization per IEC 60947-5-1 (Inductive) Thermal Current (non switching) Fuses Input (internal elect.) Output (external) Min. Switched Current/Voltage Maximum Dropout Time Indication LEDs Features * * * * Safety category according to wiring Dual channel inputs 8 N.O. safety outputs 2 N.C. auxiliary outputs Impulse Withstand Voltage Installation Group Pollution Degree Operating Temperature Humidity Enclosure Protection Terminal Protection Conductor Size Torque Settings--term. screws Case Material Mounting Weight Electrical Life 222V AC/4A/880VA cos=0.35 220V AC/1.7A/375VA cos=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W Mechanical Life Vibration Shock See Output Ratings on page 1-29 for details. Consult factory for ratings not shown. 4-56 Safety Relays Expansion Units Minotaur MSR19E Product Selection Inputs 1 N.C. or 2 N.C. Safety Outputs 8 N.O. Auxiliary Output 2 N.C. Power Supply 24V AC/DC and 120V AC 24V AC/DC and 240V AC Catalogue Number 440R-ZBE820AZ1 440R-ZBE820AZ2 Dimensions--mm (inches) Block Diagram 90 (2.34) 103 (4.06) A1 A2 B1 S4 S3 J1 13 23 33 43 53 63 73 83 91 101 PTC K1 97 (3.82) 94 (3.7) 97 (3.82) ~ 24V DC Power B2 Logic Input Short K2 S2 S1 J2 14 24 34 44 54 64 74 84 92 102 Typical Wiring Diagrams 24V DC open L1 L2 L3 T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 K1 A1 B1 S1 S3 J1 13 23 33 43 53 63 73 83 91 101 K2 L1 L2 L3 closed MSR18T MSR19E T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 K1 62 74 A2 B2 S2 S4 J2 14 24 34 44 54 64 74 84 92 102 M Aux K2 M Aux Ground Single Channel Gate Input, Single Channel Expansion, Single Channel Output Automatic Reset, Expansion Monitoring, No Monitored Output L open L1 L2 L3 T11 T12 X1 X2 T22 T35 A1 B1 13 23 33 43 53 61 73 K1 A1 B1 S1 S3 J1 13 23 33 43 53 63 73 83 91 101 K3 L1 L2 L3 closed MSR18T K2 T31 T32 IF1 T33 T34 A2 B2 14 24 34 44 54 62 74 MSR19E K4 A2 B2 S2 S4 J2 14 24 34 44 54 64 74 84 92 102 Reset N K1 K2 M Aux K3 K4 M Aux Dual Channel Gate Input, Dual Channel Expansion, Dual Channel Output Monitored Manual Reset, Expansion Monitoring, Monitored Output 4-57 |
Price & Availability of MSR19E |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |