![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
R/SEC/R058-002/B/1/03/2004 RELAIS REED A CONTACT SEC INVERSEUR BISTABLE REED RELAY / BISTABLE CHANGE OVER DRY CONTACT Pour circuit imprime / page 1 / 2 F/GB For printed circuit board Un contact inverseur bistable / bistable change over contact sous capot metal/ In metal cover R0583 W01 caracteristisques principales/ main characteristics tension maximale de commutation/ maximum switching voltage courant maximal de commutation / maximum switching current puissance maximale/ contact rating 100 VDC ou crete (or peak) 200 mA REF. Marquage/Marking NRCE R0583W01 200 R05 583D R0584W01 200 R12 584D - courant traversant/ nominal current 400 mA 3VA materiau de contact/ contact material Rhodium 20,2 10,1 14 - +8 7,2 2,54 15,24 0,45 x 0,30 O 0,6 inscriptible 1+ 7,62 3,3 0,2 -7 bornage : vue de dessus pas de 2,54 mm wiring : top view step 2,54 mm dimensions en mm / dimensions in mm caracteristiques de controle/control data REF. tension max/ maximum voltage (V) tension nominale/ nominal voltage (V) tension assurant le changement d'etat du contact a l'ouverture et a la fermeture suivant la bobine et les polarites indiquees / voltage ensuring change of state (opening or closing) see polarities as shown above consommation nominale a 20 C/power dissipated on the coil at 20 C (mW) Impulsion minimale / minimal impulse (ms) R0583 7,5 5 3,5 50 5 R0584 18 12 8 150 5 Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. r celduc e l a i s R/SEC/R058-002/B/1/03/2004 page 2 / 2 F/GB caracteristiques electriques/electrical data resistance initiale de contact/ Initial contact resistance ( 100 mA/ 12 VAC) 250 m resistance de bobine/coil resistance at 20 C REF. R0583 R0584 -variation de 10% tout les 25C 2x500 2x1500 -variation 10 % each 25 C tension de tenue/ hold-on voltage - entre lames/ accross contacts 200 Vdc - entre bobine et contact/ between coil and contacts 500 Vac - entre boitier et contact /between case and contacts 500 Vac - entre boitier et bobines/ between case and coils 500 Vac - entre bobines/ between coils 100 Vdc resistance d'isolement/ insulation resistance - entre lames/ accross contacts 109 - entre bobine et contact/ between coil and contacts 109 - entre boitier et contact /between case and contacts 109 - entre boitier et bobine/ between case and coil 109 - entre bobines/ between coils 106 frequence de resonnance de l'interrupteur / resonnance frequency of the switch 3000 Hz temps de fermeture, rebonds inclus/ operate time, bounces included contact travail / normaly open 1,5 ms temps d'ouverture / release time contact repos / normaly closed 2 ms Duree de vie electrique/ Electrical life time voltage 100V 24mA > 5 106 30 V 100 VAC 24V = 100mA > 2.4 106 200 180 5,6 60 >1. 109 op 830 1,2 5V Duree de vie mecanique/ mecanical life ( mA ) current expectancy 10 life expectancy ( - x 106 op. ) 200 caracteristiques physiques/ physical data temperature de fontionnement/ operating temperature temperature de stockage/ storage temperature poids/ weight chocs/shocks (11ms) vibrations ( 50 to 4000 Hz ) rate of failure ( - x 10-9 defaut / op.) 5 - 40 a + 85 C - 40 a + 100 C 4 gr. max. 20 g 30 g celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of R0583W01
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |