![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/MOD/SPA07420/D/14/05/2002 Relais Statique AC AC Solid State Relay * Compatibilite du brochage avec les Relais Electro-mecaniques . * Commande AC et DC Non polarisee. * Sortie AC synchrone. * Importantes surcharges en courants admissibles. * Haute immunite aux perturbations exterieures. * Ecreteur de surtension integre. * Pin to pin compatible with Electromechanic Relays. * AC and Non-polarized control. * Zero-cross AC Output. * Sustain high Inrush current . * High immunity level. * Integrated clamping voltage. 29 12,7 page 1 / 2 F/GB SPA07420 24V AC/DC input 230V/4A AC output 12-275VAC L1 N grille 2,54mm /grid 0,1" vue de dessous / bottom view A1 NO C 25,4 plc, logic ,...C A2 LOAD A1 A2 SPA 5,1 Percage/Hole O1,1 Caracteristiques de commande (a 20C) / Control characteristics (at 20C) DC-AC Parameter Symbol Min Nom Max Tension de commande / Control voltage Uc 12-15 24 30 Courant de commande / Control current (@ Uc nom ) Ic 4,1-6,1 9,3-10,2 12-13 Tension de relachement/Release voltage Uc off 2,5 Resistance interne / Input internal resistor fig.1 Rc 2100 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie / Input-output isolation Uimp 4000 14 13 12 Fig. 1 :Caracteristique d'entree / Control characteristic Unit V mA V V 11 10 9 AC DC Ic (mA) 8 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 35 Uc (V) Caracteristiques thermiques / thermal characteristics Parameter Conditions Temperature de jonction max. / Maximum junction temperature Plage de temperature de fonctionnement /Operating temperature range Boitier / Case Resistance thermique jonction-boitier/Junction-case thermal resistance Uc nom, Tc-Ta=50C Resistance thermique jonction-Ambiant/Junction-ambient thermal resistance Uc nom, Tc-Ta=50C Constante de temps thermique du boitier/Case thermique delay time Tc-Ta=50C Caracteristiques generales / General characteristics Poids/Weight Temperature de soudage max / Maximum soldering heat(1 mm boitier/case) Conformite / Conformity Symbol Tj max Tc max Rthj-c Rthj-a Tthc Typ. 125 -40 +100 7,4 30 6 18 260 C C C/W C/W minute g C 10 s EN60947-5-1 Ts max Proud to serve you All technical characteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. celduc r e l a i s S/MOD/SPA07420/D/14/05/2002 page 2 / 2 F/GB Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete (ecreteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal/ Nominal current ( see Fig. 2 ) Conditions Symbol Typ. Unit Ul 230 V rms Ulmin-max 12-275 V rms Up 600 V Usync 10 V Ua 5 V Il AC12 4 A rms Il AC13 2,5 A rms Il AC15 2,5 A rms Itsm 100 A Vd 1,1 V Ilk <1 mA Ilmin 50 mA ton max 12 ms toff max 20 ms f 1-440Hz Hz dv/dt 500 V/s di/dt 100 A/s I2t 50 A2s Wmax 8,6 J 1kV criterion A /4kV criterion B Control :0,5kV crit. A Output 1kV crit. A Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) Varistor interne / VDR EMC Test d'immunite conduite/Conducted immunity level EMC Test d'immunite conduite/Conducted immunity level Il nom AC12 AC13 AC15 tp=10ms (Fig. 3) @ Il nom @Ul, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz tp=2ms IEC 1000-4-4 (bursts) IEC 1000-4-5 (shocks) Fig. 2 : Courant en fonction de la temperature ambiante / Load current vs. ambient temperature characteristics 5 95 4,5 Fig. 3 : Courant de surcharge non repetitif / Non repetitive surge current T c (C) @ Tjmax 90 100 105 110 4 3,5 3 Il (A) 2,5 2 1,5 1 0,5 0 0 10 20 30 40 50 60 T amb (C) 70 80 90 100 80 70 Itsm (Apeak) 60 50 40 30 Tjmax=125C Tc=90C 115 120 20 10 0 110 1 10 100 Nombres de cycles / Number of cycles 1000 Precautions : * Dans le cas de plusieurs modules cote a cote, prevoir un derating en courant. * Sur charges avec capacites a l'entree ( filtre, ballast de lampe a decharge,....) des surtensions peuvant se produire sur le relais,il est necessaire d'utiliser des relais 400VAC : nous consulter. Cautions : * In case of many SSRs side by side , take a derating current in to account . * On loads with capacitor at the input (filters , ballasts for discharge lamps,...) , some overvoltages can appear , so it is necessary tovuse 400VAC SSRs : Please contact us. celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of SPA07420
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |