![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
90W AC-DC Single Output Desktop Features : Universal AC input / Full range FM90C No load power consumption<0.75W@240VAC 3 pole AC inlet IEC320-C6 Class I power (with earth pin) Built-in active PFC function, PF>0.90 Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Approvals: UL / CUL / TUV / CB / FCC / CE 1 year warranty TUV SUD series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE OUTPUT RATED POWER FM90C12-P1M FDF0903-C Note.2 12V GeprUfte Sicherheit FM90C19-P1M FDF0903-A 19V 4.75A 0 ~ 4.75A 90W 150mVp-p 3.0% 1.0% 2.0% 127 ~ 370VDC FM90C24-P1M FDF0903-D 24V 3.75A 0 ~ 3.75A 90W 150mVp-p 3.0% 1.0% 2.0% 6.60A 0~ 6.60A 80W RIPPLE & NOISE (max.) Note.3 150mVp-p VOLTAGE TOLERANCE Note.4 5.0% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR Note.5 Note.6 1.0% 4.0% 90 ~ 264VAC 47 ~ 63Hz PF 0.90/230VAC 80% 1.3A/100VAC 100A/240VAC 0.75mA / 240VAC SETUP, RISE , HOLD UP TIME 300ms, 50ms , 10ms at full load INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD 80% 82% PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & EMC (Note. 7) 110 ~ 150% rated output voltage Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 ~ 150% rated output voltage Protection type : Clamp by zener diode 0 ~ + 50 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 3AXES 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:1.5KVAC; I/P-FG: 1.5KVAC I/P-O/P, I/P-FG: 100M ohms/500VDC/25 /70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) class B, FCC part 15 class B HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 30K hrs min. MIL-HDBK-217F (25 ) 133*58*30mm (L*W*H) 406g; 32pcs/14.5Kg/CARTON Standard type P1M: 2.5 * 5.5 OTHERS DIMENSION PACKING PLUG CABLE CONNECTOR NOTE * 11mm, tuning folk type center positive for stock ; Other type available by customer requested Standard type UL1185, 16awg*4fts for stock ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerence: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 0% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:FM90C-SPEC 2008-05-08 90W AC-DC Single Output Desktop Mechanical Specification FM90C series Unit:mm UL 1185 16AWG 1200 50mm 30 5mm 11 0.5mm POWER LED C"+" ID 2.5 x OD 5.5 133 30 Plug Assignment Standard plug: P1M (option) C5.0 P1M P/N OUTPUT + 58 46 73.5 CENTER Derating Curve Static Characteristics Ta=25 100 90 100 80 70 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 70 50 60 50 40 (HORIZONTAL) 60 70 80 90 100 260 Ta ( ) INPUT VOLTAGE File Name:FM90C-SPEC 2008-05-08 |
Price & Availability of FM90C24-P1M
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |