60W Single Output Switching Power Supply Features : LPC-60 series Constant current design Universal AC input / Full range Epoxy encapsulated with IP67 level Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Over current / Over voltage Fully isolated plastic case Cooling by free air convection UL1310 Class 2 power unit, pass LPS 100% full load burn-in test Low cost, high reliability Suitable for LED lighting and moving sign applications 2 years warranty SPECIFICATION MODEL DC VOLTAGE DC VOLTAGE RANGE CURRENT RANGE RATED POWER OUTPUT VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT CURRENT LIMIT PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Note.4 LPS IP67 LPC-60-1050 48V 9 ~ 48V 1050mA 50.4W 5.0% 1.0% 2.0% Note.6 500ms, 120ms / 230VAC ( except for 34V ) ( for 34V only) LPC-60-1400 42V 9 ~ 42V 1400mA 58.8W 200mVp-p LPC-60-1750 34V 9 ~ 34V 1750mA 59.5W 200mVp-p RIPPLE & NOISE (max.) Note.2 200mVp-p 500ms, 120ms / 115VAC at full load 50ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 87% 16ms/115VAC at full load 85% 87% 1.2A/115VAC 0.7A/230VAC COLD STAR 30A/115VAC 60A/230VAC 0.25mA / 240VAC 5% rated output current Protection type : Constant current limiting type 50.4 ~ 60V 44.1 ~ 56.7V Protection type : Shut off o/p voltage, clamping by TVS diode -30 ~ +70 -40 ~ +80 (Refer to output load derating curve) , 10 ~ 95% RH 20 ~ 90% RH non-condensing 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, CAN/CSA C22.2 No. 223-M91(for 34V only), IP67 approved, design refer to TUV EN60950-1, EN61347-2-13 I/P-O/P:3KVAC 39.1 ~ 45.9V SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 732Khrs min. MIL-HDBK-217F (25 ) 162.5*42.5*32mm (L*W*H) 0.4Kg; 32pcs/13.8Kg/0.56CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the derating curve for more details. 5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:LPC-60-SPEC 2008-12-11 60W Single Output Switching Power Supply Mechanical Specification LPC-60 Case No. 976A series Unit:mm 600 18AWG 162.5 3.5 600 42.5 AC/L(Brown) AC/N(Blue) 3.5 3.6 3.5 16AWG 3.6 3.5 +V(Red) -V(Black) Block Diagram fosc : 60KHz I/P EMI FILTER & RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER O.C.P. +V -V O.L.P. PWM CONTROL DETECTION CIRCUIT Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 60 LOAD (%) 40 LOAD (%) 60 50 40 20 -30 -15 0 15 30 40 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPC-60-SPEC 2008-12-11 32 |
Price & Availability of LPC-60
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |