If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
100W Single Output without PFC Function Features : LPS-100 series Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fix switching frequency at 134KHz 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LPS-100-3.3 LPS-100-5 3.3V 20A 0 ~ 20A 66W 5V 20A 0 ~ 20A 100W 100mVp-p 4.5 ~ 5.7V 3.0% 0.5% LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48 7.5V 13.3A 0 ~ 13.3A 99.75W 100mVp-p 6 ~ 9V 2.0% 0.5% 12V 8.4A 0 ~ 8.4A 100.8W 100mVp-p 10 ~ 13.2V 2.0% 0.5% 13.5V 7.5A 0 ~ 7.5A 101.25W 100mVp-p 12 ~ 15V 2.0% 0.5% 15V 6.7A 0 ~ 6.7A 100.5W 100mVp-p 13.5 ~ 18V 2.0% 0.5% 1.5% 24V 4.2A 27V 3.8A 48V 2.1A 0 ~ 2.1A 100.8W 200mVp-p 41 ~ 56V 1.0% 0.5% 0.5% 0 ~ 4.2A(6A 10s) 0 ~ 3.8A 100.8W(144W 10s) 102.6W 150mVp-p 20 ~ 26.4V 1.0% 0.5% 0.5% 150mVp-p 26 ~ 32V 1.0% 0.5% 0.5% RIPPLE & NOISE (max.) Note.2 150mVp-p 3 ~ 3.6V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) 0.5% 2.0% 2.0% 800ms, 50ms/230VAC 20ms/230VAC 47 ~ 63Hz 69% 2.3A/115VAC 77% 1.5% 1.5% 1.5% 1200ms, 50ms/115VAC at full load 248 ~ 370VDC 79% 79% 20ms/115VAC at full load 88 ~ 132VAC / 176 ~ 264VAC auto switch 77% 1.5A/230VAC 60A/230VAC 80% 80% 81% 81% COLD START 30A/115VAC <1mA / 240VAC 105 ~ 140% (+24V: above 6.5A) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A 203.6Khrs min. MIL-HDBK-217F (25 222*62*32mm (L*W*H) 0.45Kg; 24pcs/12.5Kg/1.39CUFT ) OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24). 6. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:LPS-100-SPEC 2008-03-25 100W Single Output without PFC Function Mechanical Specification 222 5 212 LPS-100 series Unit:mm 5 FG CN2 CN1 1 2 3 4 5 8 7 6 5 4 3 2 1 62 52 AC FUSE F4A/250V +V ADJ. 43.5 AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment FG No pin AC/N AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 3max. 32 DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2,3,4 5,6,7,8 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram 115/230VAC AUTO SWITCH RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. fosc : 135KHz POWER SWITCHING +V -V I/P EMI FILTER FG O.L.P. PWM CONTROL Derating Curve Static Characteristics (12V) Ta=25 100 12 80 250 200 150 100 LPS-100-5V 60 11 10 9 +12V 8 7 LOAD (%) Convection (3.3V,7.5V~48V) 40 50 25 20 -10 0 10 20 30 40 50 60 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPS-100-SPEC 2008-03-25 OUTPUT RIPPLE (mVp-p) 18 CFM min Forced Air 13 +12V 300 OUTPUT VOLTAGE (V) |
Price & Availability of LPS-100
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |