![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/TRI/SGT965960E/A/2/03/2004 page 1 / 2 F/GB Relais Statique Triphase Three Phase Solid State Relays Entraxe 47,5mm /47.5mm mounting * Sortie AC pour charge resistives. * Commande 90-240 VAC avec LED. * Possibilite de protection IP10 en option:Capot 1K199 000. * AC output for resistive loads. * 90-240 VAC control voltage with LED. * Protection IP10 optional (1K199 000). Dimensions / Dimensions: Application typique /Typical application: R S T R S T R S T SGT965960E 24 to 600 VAC - 50 ARMS Circuit equivalent/Equivalent circuit : 1L1 39,5 Adaptateur / Adapter LED 2T1 3L2 82,7 19 5,3 ON/OFF A1 19 = A2 Resistive or inductive load Adaptateur / Adapter M 4T2 5L3 1L1 A2 - 3L2 5L3 @25C 47,6 With suitable heatsink See instruction sheet 1L1 3L2 5L3 A1+ 58,4 73,5 23 Adaptateur / Adapter plots O6,3 vis M3 2T1 4T2 6T3 6T3 2T1 4T2 6T3 plots O9,5 vis M5 8 92 100 8 Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parametre / Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc ) Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Tension inverse / Reverse voltage Symbol Uc Ic Uc off Rc Urv Min 90 4 4 AC Nom Max 240 11 Unit V mA V K V VRMS VRMS V fig. 1 :Caracteristique d'entree / Control characteristic 15 10 5 0 0 50 100 150 200 250 Uc (V) 21 Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Ui 4000 Isolement sortie-semelle/Output-case isolation @500m Ui 3300 Tension assignee isolement/ Rated impulse voltage Uimp 4000 Caracteristiques generales / General characteristics Parametre / Parameter Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range Conditions Symbol Ic (mA) Typ. 370 -40 / +100 -40 / +100 Unit g C C Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. celduc r e l a i s S/TRI/SGT965960E/A/2/03/2004 Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametre / Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC-51/ AC-51 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite conduite / Conducted immunity level EMC Test d'immunite conduite / Conducted immunity level Conformite / Conformity Caracteristiques thermiques / thermal curves : 220 200 180 160 Total wasted power (W) 140 120 100 page 2 / 2 F/GB Conditions Symbol Ue Uemin-max Up Usync Ua Ie AC-51 Itsm Vd Ilk Ie min ton max toff max f dv/dt di/dt I2t Typ. 400 24-600 1200 24 10 50 Unit V rms V rms V V V A rms Ie nom ( see Fig. 2 ) tp=10ms (Fig. 3) @ Ie nom @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz IEC 1000-4-4 (burst) IEC 1000-4-5(schocks) EN60947-4-x 550 A 1,4 V 1 mA 5 mA 10 ms 10 ms 10-440 Hz 500 V/s 50 A/s 1500 A2s 2kV criterion A 2kV crit.A with external VDR Full on-state 0,3K/W 0,55K/W 0,95K/W 80 60 40 20 0 without heatsink 1,2K/W Fig.3 Courbes de surcharge de courant / Overload current curves 05 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 90 100 RMS load current (A) Ambient temperature (C) Surge current Itsm (A peak) = f(t) 600 Itsm (Apeak) for models with Itsm =550A No repetitive Itsm (Apeak)=f(t) without voltage reapplied 400 1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's . 200 Repetitive Itsm (Apeak)=f(t) with voltage reapplied for initial Tj =70C 0 0,01 0,1 t (s) 1 10 Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge. Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains. celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of SGT965960E
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |