![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters FEATURES * 0...100 mbar to 0...10 bar, 0...2 to 0...150 psi gage or absolute * For corrosive media * 0...10 V, 1...6 V, 0...20 mA or 4...20 mA output * Field interchangeable * For harsh environments MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316L), PVC, PUR, NBR11 Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1 ELECTRICAL CONNECTION 0...10 V, 1...6 V output +Vs red Vout yellow -Vs black bare 13 to 30 V SPECIFICATIONS9,10 Maximum ratings Supply voltage (reverse polarity protection) 13...30 V BTE(M)/PTU6...0..., 1... 12...36 V BTE(M)/PTU6...4..., 5...2 Maximum load current BTE(M)/PTU6...0..., 1... Temperature limits Storage Operating Compensated Vibration (5 to 500 Hz) Mechanical shock Proof pressure3 sensor V GND 0...20 mA output +Vs red Iout blue -Vs black bare 12 to 36 V sensor 10 mA RL V GND -40 to 85C -25 to 85C 0 to 70C 10 gRMS 50 g 2 x rated pressure 4...20 mA output +Vs red sensor -Vs black bare V 12 to 36 V RL GND August 2008 / 104 1/6 www.sensortechnics.com BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters COMMON PERFORMANCE CHARACTERISTICS1 Characteristics Operating pressure BTEM6100... BTEM6250... BTEM6350... BTEM6500... BTE6001... BTE6002... BTE6005... BTE6010... PTU6002... PTU6003... PTU6005... PTU6010... PTU6015... PTU6030... PTU6050... PTU6100... PTU6150... Thermal effects (0 to 70C) 4 Min. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Typ. Max. 100 250 350 500 1 2 5 10 2 3 5 10 15 30 50 100 150 Unit mbar bar p si Offset Span Offset Span 0.02 0.02 0.03 0.03 0.1 0.1 0.2 0.04 1 0.04 0.04 %FSO/C (-25 to 0C, 70 to 85C) Non-linearity and hysteresis (BSL) Repeatability Long term stability 6 5 0.25 %FSO Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span ms %FSO/V 0.05 0.05 August 2008 / 104 2/6 www.sensortechnics.com BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters INDIVIDUAL PERFORMANCE CHARACTERISTICS1 0...10 V output (VS = 15 V, RL > 100 k, tamb = 25C) Characteristics Zero pressure offset Full scale span 7 Min. -0.15 9.9 Typ. 0 10.0 100 Max. 0.15 10.1 50 Unit V mW Output impedance Power consumption (no load) 1...6 V output (VS = 15 V, RL > 100 k, tamb = 25C) Characteristics Zero pressure offset Full scale span7 Full scale output Output impedance Power consumption (no load) Min. 0.85 4.9 Typ. 1.0 5.0 6.0 Max. 1.15 5.1 50 Unit V mW 100 4...20 mA output (VS = 15 V, RL > 100 , tamb = 25C) Characteristics Zero pressure offset Full scale span 7 Min. 3.85 15.9 Typ. 4.0 16.0 0.1 260 Max. 4.15 16.1 Unit mA mW Output impedance Power consumption (IL = 20 mA) 0...20 mA output (VS = 15 V, RL > 100 , tamb = 25C) Characteristics Zero pressure offset Full scale span 7 Min. -0.15 19.9 Typ. 0 20.0 0.1 260 Max. 0.15 20.1 Unit mA mW Output impedance Power consumption (IL = 20 mA) August 2008 / 104 3/6 www.sensortechnics.com BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters ELECTROMAGNETIC CAPABILITY8 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 2 kV Grade 4 8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz) Criterion A Interference <1 % FSO EN61000-4-4: EN61000-4-2: EN61000-4-6: B B <1 % FSO <1 % FSO A <1 % FSO Specification notes (for all devices): The package is a all-sealed housing. Gage devices are vented through an integral PE tube of the connecting cable. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagrams. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70C relative to 25C. All specifications shown are relative to 25C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Test are in accordance with EN61000-6-2, April 1999. 9. CE-labelling is in accordance with 89/336/EEC. 10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 11. Other sealing materials are available on request. 1. 2. August 2008 / 104 4/6 www.sensortechnics.com BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters OUTPUT CHARACTERISTICS Voltage output versions Vout 10 V9 8 7 6 5 4 3 2 1 0 20 40 60 80 100 % operating pressure BTE(M)/PTU6...1... BTE(M)/PTU6...0... Current output versions lout 20 mA 18 16 14 12 10 8 6 4 2 0 20 40 60 80 100 % operating pressure BTE(M)/PTU6...4... BTE(M)/PTU6...5... LOAD LIMITATION 0...20 mA output version 4...20 mA ouput version 1400 Ohm 1200 1000 800 600 400 200 operating range 0 5 10 15 20 25 30 35 V supply voltage August 2008 / 104 5/6 www.sensortechnics.com BTE6000 / PTU6000...CS Series Submersible precision stainless steel transmitters OUTLINE DRAWING NOM 151 (5.95) NOM 2000 (78.74) NOM 70 (2.76) other cable lengths on request O 24 (0.95) O 27 (1.06) Hydrophobic filter (incl. in delivery) mass: typ. 350 g (without cable) dimensions in mm (inches) ORDERING INFORMATION BTE/PTU calibration BTE: calibration in bar PTU: calibration in psi mbar-ranges pressure range 100: 250: 350: 500: 001: 002: 005: 010: 0...100 0...250 0...350 0...500 mbar mbar mbar mbar 002: 0...2 psi 003: 0...3 psi 005: 0...5 psi 010: 0...10 psi 015: 0...15 psi 030: 0...30 psi 050: 0...50 psi 100: 0...100 psi 150: 0...150 psi M 6xxx x x C x S submersible cable length in m cable version output signal 0: 1: 4: 5: 0...10 V 1...6 V 4...20 mA 0...20 mA 0...1 bar 0...2 bar 0...5 bar 0...10 bar pressure mode G: gage pressure A: absolute pressure (available for pressure ranges from 1 bar/15 psi absolute upwards only!) Note: Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. August 2008 / 104 6/6 www.sensortechnics.com |
Price & Availability of BTEM6350A0CXS
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |