OEM submersible level sensors
FEATURES * 0...50 to 0...200 mbar (approx. 0...1.67 to 0...6.70 ft H2O) * Capacitive ceramic pressure cells * For corrosive media * 4...20 mA output * High overpressure resistance MEDIA COMPATIBILITY
Wetted materials: Ceramic Al2O3, stainless steel 1Cr18Ni9Ti, NBR, Viton, PE (PUR) Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1
SPECIFICATIONS6
Maximum ratings Supply voltage2 Temperature limits Storage Operating Compensated Proof pressure3 12...30 V
ELECTRICAL CONNECTION
-30...85 C -30...80 C -30...70 C 10 x rated pressure
+Vs Black Sensor -Vs Red
12...30 V
V RL GND
October 2008 / 653
1/3
www.sensortechnics.com
KTE2000...CS Series
OEM submersible level sensors
INDIVIDUAL PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure KTEM2050... KTEM2100... KTEM2200...
Min.
0 0 0
Typ.
Max.
50 100 200
Unit
mbar
Zero pressure offset Full scale span Thermal effects4 Accuracy5 Long term stability Vibration (200 Hz/g) -20...70 C -20...-30 C
4.0 16.0 0.015 0.02 0.75 0.1 0.01
mA %FSO/C %FSO %FSO/year %FSO
LOAD LIMITATION2
Rmax =
Vs - 12 V 0.02 A
Specification notes:
1. 2. 3. 4. 5. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. All specifications shown are relative to 25C. Accuracy is the combined error from offset and span calibration, linearity, hysteresis and repeatability. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
6.
October 2008 / 653
2/3
www.sensortechnics.com
KTE2000...CS Series
OEM submersible level sensors
OUTLINE DRAWING
79.0 56.0 10.0 5 m cable incl. in delivery (other cable lengths on request)
O 42.0
Vent tube
dimensions in mm
ORDERING INFORMATION KTEM2 xxx G 4 C5S
Cable submersible 5: 5 m cable length (other cable lengths on request) output signal 4: 4...20 mA
Pressure range 050: 0...50 mbar (approx. 1.67 ft H2O) 100: 0...100 mbar (approx. 3.35 ft H2O) 200: 0...200 mbar (approx. 6.70 ft H2O) Pressure mode G: gage pressure
Note: Other pressure ranges and calibrations (e.g. psi, inch H2O, cm H2O) are available on request. Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. October 2008 / 653 3/3
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of KTEM2050G4C5S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X