If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC Medical 25 Watts PBM25 Series * THE XPERTS IN POWER Small Size 2.50" x 4.25" x 0.96" * Low Leakage Current * Medical Safety Agency Approvals * Both Line and Neutral Fused * Meets Class B, EN55011 Conducted * Fixed Switching Frequency Specification Input Input Voltage Input Frequency Input Current Inrush Current Earth Leakage Current * * * * * 85-264 VAC 47-63 Hz 0.7 A (rms) at 115 VAC, 0.4 A (rms) at 230 VAC 10 A max at 115 VAC, 25 A max at 230 VAC 90 A max at 115 VAC 60 Hz 150 A max at 230 VAC 50 Hz General Efficiency Isolation * * 68% minimum for 5 V & multi output models, 70% minimum all others 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground 42 KHz 5 KHz 500,000 hrs per min MIL-HDBK-217F 4.25 x 2.50 x 0.96" 107.95 x 63.50 x 24.38 mm Single output models 163 g, Multi output models 175 g Switching Frequency * MTBF * Size * Weight * Output Output Voltage Output Power Minimum Load Start Up Delay Start Up Rise TIme Hold up Time Initial Set Accuracy Line Regulation Total Regulation Transient Response Ripple & Noise Overvoltage Protection Overcurrent Protection Short Circuit Protection Temperature Coefficient * * * * * * * * * * * * 5.1 to 28 VDC, See Table 25/28 Watts, See Table No minimum for single outputs models See Table for multi outputs models 3 s max 12 ms 10 ms minimum at 110 VAC 1% 0.5% max at full load See Table 4% max deviation, 500 s recovery time for a 25% load change 1% max pk-pk (See Note 1) Provided on output 1 only; set at 112-132% of its nominal output voltage 125-200% with auto recovery Trip & restart with auto recovery 0.04%/C Environmental Operating Temperature Storage Temperature Cooling Relative Humidity Operating Altitude Shock Vibration * 0 C to +70 C, derate linearly from 100% load at +50C to 50% load at +70 C -40 C to +85 C Convection cooled 5-95%, non-condensing 3000m 20 G in 3 directions, 3 times each 0.15mm over 10-55Hz and 1 octave/min. 3 axes for 30 min * * * * * * EMC & Safety EMC ESD Radiated Immunity EFT/Burst Surge Safety Approvals * * * * * * EN55011 (CISPR11) Class B & FCC Class B conducted EN61000-4-2 Level 2 Perf Criteria A EN61000-4-3 3 V/m Perf Criteria A EN61000-4-4 Level 3 Perf Criteria A EN61000-4-5 Level 3 Perf Criteria A UL2601-1, CSA C22.2 No 601.1, EN60601-1, IEC 601-1 * * * * www.xp-medical.com sales@xp-medical.com * OUTPUT VOLTAGE & CURRENT RATINGS Output Power Maximum 28 W 28 W 28 W 28 W 28 W 25 W 25 W 25 W 25 W 25 W Notes Vnom 5.1 V 12.0 V 15.0 V 24.0 V 28.0 V 5.1 V 5.1 V 5.1 V 5.1 V 5.1 V Output 1 Imin Imax 0.0 A 5.5 A 0.0 A 2.3 A 0.0 A 1.9 A 0.0 A 1.2 A 0.0 A 1.0 A 0.4 A 2.5 A 0.4 A 2.5 A 0.4 A 2.5 A 0.4 A 2.5 A 0.4 A 2.5 A Reg.(2) 2% 1% 1% 1% 1% 3% 3% 3% 3% 3% Vnom Output 2 Imin Imax Reg.(2) Vnom Output 3 Imin Imax Reg.(2) PBM25 Model Number PBM25US05 PBM25US12* PBM25US15* PBM25US24* PBM25US28* PBM25UD01* PBM25UD02* PBM25UT01* PBM25UT02* PBM25UT03* +12 +24 +12 +15 +24 V V V V V 0.2 0.1 0.2 0.1 0.1 A A A A A 1.5 0.8 1.5 1.0 0.8 A A A A A 5% 5% 5% 5% 5% -12 V -15 V -12 V 0.05 A 0.05 A 0.05 A 0.2 A 0.2 A 0.2 A 4% 4% 4% * 1. Ripple and noise measured with 20 MHz bandwidth with 10 F electrolytic in parallel with 0.1 F ceramic. 2. Regulation includes line and load regulation and set point accuracy. All multiple output models may be operated at no-load, but output regulation will increase to 10% on outputs V2 & V3. * Also available from Farnell InOne, see pages 350 & 351. Mechanical Details - Single Output Models PIN CONNECTIONS Pin Function 1 Return 2 Return 3 Output 1 4 Output 1 Notes: 1. Dimensions shown in inches (mm). 2. Tolerance 0.03 (0.76) maximum. 3. Input connector P1 mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector P2 mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal. 5. Weight 163 g. 6. Covers available, order part number PBM25 COVER*, or add suffix `-C' to have cover fitted (78.8 x 12.0 x 34.8 mm). 7. Mating connector kit available, order part number PBM25 CONKT-S*. Mechanical Details - Multi Output Models PIN CONNECTIONS Pin Dual Output Triple Output 1 Output 2 Output 2 2 Output 1 Output 1 3 Output 1 Output 1 4 Common Return Common Return 5 Common Return Common Return 6 No Connection Output 3 Notes: 1. Dimensions shown in inches (mm). 2. Tolerance 0.03 (0.76) maximum. 3. Input connector P1 mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector P2 mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal. 5. Weight 175 g. 6. Covers available, order part number PBM25 COVER*, or add suffix `-C' to have cover fitted (78.8 x 120.0 x 34.8 mm). 7. Mating connector kit available, order part number PBM25 CONKT-D/T*. www.xp-medical.com sales@xp-medical.com Rev 3.1 |
Price & Availability of PBM25UD01
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |