TRUMPower TS200 Series 200W Compact AC/DC Power Supplies Universal AC input / Full range Built-in active PFC function High efficiency up to 90% (typ) Protections: Short circuit / Overload / Over voltage / Over temperature PWM control and regulated High power density 9.78W/inch3 5"x3" compact size Built-in remote sense function ZVS technology to reduce power dissipation Free air convection for 150W and 200W with 20.5 CFM forced air 3 years warranty Features : SPECIFICATION MODEL PART NO. DC VOLTAGE RATED CURRENT TS200-05 PPS-200-5 5V 36A TS200-12 PPS-200-12 12V 16.6A 0 ~ 12.5A 0 ~ 16.6A 150W 199.2W 100mVp-p 10.8 ~ 13.2V 3.0% 0.5% 1.0% TS200-15 PPS-200-15 15V 13.3A 0 ~ 10A 0 ~ 13.3A 150W 199.5W 100mVp-p 13.5 ~ 16.5V 3.0% 0.5% 1.0% TS200-24 PPS-200-24 24V 8.3A 0 ~ 6.25A 0 ~ 8.3A 150W 199.2W 150mVp-p 21.6 ~ 26.4V 2.0% 0.5% 1.0% TS200-27 PPS-200-27 27V 7.4A 0 ~ 5.56A 0 ~ 7.4A 150W 199.8W 150mVp-p 24.3 ~ 30V 2.0% 0.5% 1.0% TS200-48 PPS-200-48 48V 4.167A 0 ~ 3.13A 0 ~ 4.167A 150W 200W 250mVp-p 43.2 ~ 52.8V 2.0% 0.5% 1.0% CURRENT RANGE (convection) 0 ~ 26A CURRENT RANGE (20.5CFM FAN) 0 ~ 36A RATED POWER (convection) 130W RATED POWER (20.5CFM FAN) 180W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE 4.5 ~ 5.5V 4.0% 0.5% 1.0% 1200ms, 60ms/230VAC 90 ~ 264VAC 47 ~ 63Hz PF>0.93/230VAC 86% 2500ms, 60ms/115VAC at full load 12ms/230VAC/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 89% 89% 89% 89% 90% 2.2A/115VAC 1.2A/230VAC COLD START 70A/230VAC <2mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.6 ~ 7.25V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & (Note 4) EMC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 108.4Khrs min. MIL-HDBK-217F (25 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT ) OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 can not be shorted. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. Tumbler Technologies + TRUMPower * Santa Clara, CA, USA * 408-988-6616 * sales@trumpower.com * www.TRUMPower.com TRUMPower Mechanical Specification 127 5 115.6 200W Compact AC/DC Power Supplies TS200 Series Unit:mm 12 6.4 HS2 CN3 HS1 SVR1 1 2 3 4 5 6 7 8 CN5 LED1 76.2 64.8 1 2 3 CN1 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 43. 5 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 50mm Air flow direction 20.5CFM DC Output Connector (CN5) : JST B8P-VH or equivalent Pin No. 1~4 5~8 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent FAN Remote Sense(CN3) : Molex 5045-02 or equivalent Pin No. 1 2 Assignment RSRS+ 34.6 Mating Housing Molex 5051 or equivalent Terminal Molex 4809 or equivalent Block Diagram EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER 3max. HS1,HS2 can not be shorted fosc : 100KHz I/P +V -V FG DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta = 25 125 100 100 With FAN 90 80 70 70 LOAD (%) 50 Without FAN LOAD(%) 60 70 (HORIZONTAL) 60 50 40 20 -20 0 10 20 30 40 50 90 115 125 135 155 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz Tumbler Technologies + TRUMPower * Santa Clara, CA, USA * 408-988-6616 * sales@trumpower.com * www.TRUMPower.com |
Price & Availability of TS200
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |