![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
160PC...-PCB Series Fully signal conditioned low pressure transducer FEATURES * Pressure ranges from 0...2.5 "H2O (0...6.4 cm H2O) to -20...120 cm H2O (custom calibrations available) * 1...6 V output * Output ratiometric to supply voltage * Precision temperature compensated and calibrated * Special calibrations for small volumes on request * EMC-proof SERVICE Non-corrosive, non-ionic working fluids, such as dry air and dry gases Scale: 1 cm 1 inch SPECIFICATIONS Maximum ratings Excitation voltage Output current Source Sink Output load capacitance Temperature limits Operating Storage Compensated Humidity (non-condensing) Proof pressure1 7...16 V ELECTRICAL CONNECTION 10 mA 5 mA 10 nF +Vs 7 V to 16 V (NOM 8.00 V) 160PC...-PCB Vout V -Vs -25 to +85C -40 to +125C -18 to +63C 0 - 95 %RH 350 mbar June 2006 / 567 1/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 161PC01D-PCB PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.95 5.90 3 (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Typ. 1.00 5.0 6.00 Max. -1.0 1.05 Unit p si d V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects (-18 to +63C) Offset Span Combined offset and span Non-linearity (BSL) Ratiometricity Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 2 6.10 1.0 1.0 1.0 1.0 %FSS Hysteresis and repeatability 7 to 8 V and 8 to 9 V 9 to 12 V 0.15 0.5 2.0 20.0 1 10 mA msec V/m 162PC01D-PCB PERFORMANCE CHARACTERISTICS Characteristics Min. 0 0.95 5.90 Offset Span Combined offset and span 1.00 5.00 6.00 6.10 1.0 1.0 1.0 1.0 0.15 7 to 8 V and 8 to 9 V 9 to 12 V 0.5 2.0 20.0 1 10 mA msec V/m %FSS (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Typ. Max. 1.0 1.05 Unit p si d V Operating pressure Zero pressure offset Span4 Full scale output Thermal effects (-18 to +63C) 3 Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 2/6 June 2006 / 567 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D36-PCB PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Characteristics Operating pressure Zero pressure offset Output voltage Thermal effects (+5 to +45C) 3 Min. -5 3.45 Typ. 3.50 1.00 6.00 Max. +5 3.55 1.20 6.10 1.0 1.0 1.0 1.0 Unit "H2O V at -5"H2O at +5"H2O Offset Span Combined offset and span 0.80 5.90 Non-linearity (BSL) Ratiometricity 2 %FSS Hysteresis and repeatability 7 to 8 V and 8 to 9 V 9 to 12 V Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 10 0.25 0.5 2.0 20.0 1 mA msec V/m 164PC01D37-PCB PERFORMANCE CHARACTERISTICS Min. 0 0.95 5.90 3 (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects (+5 to +45C) Offset Span Combined offset and span Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) June 2006 / 567 Typ. 1.00 5.0 6.00 Max. 10 1.05 Unit "H2O V 6.10 1.0 1.0 1.0 1.0 %FSS 0.25 7 to 8 V and 8 to 9 V 9 to 12 V 0.5 2.0 20.0 1 10 mA msec V/m 3/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D75-PCB PERFORMANCE CHARACTERISTICS Min. -2.5 3.45 at -2.5"H2O at +2.5"H2O 3 (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Characteristics Operating pressure Zero pressure offset Output Thermal effects (+5 to +45C) Typ. 3.50 1.00 6.00 Max. +2.5 3.55 1.20 6.10 1.25 1.25 1.25 1.0 Unit "H2O V 0.80 5.90 Offset Span Combined offset and span Non-linearity (BSL) Ratiometricity 2 %FSS Hysteresis and repeatability 7 to 8 V and 8 to 9 V 9 to 12 V Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 10 0.25 0.5 2.0 20.0 1 mA msec V/m 164PC01D76-PCB PERFORMANCE CHARACTERISTICS Min. 0 0.95 5.90 3 (unless otherwise noted, VS = 8.00 V, RL > 100 k, tamb = 25C) Characteristics Operating pressure Zero pressure offset Span4 Full scale output Thermal effects (+5 to +45C) Offset Span Combined offset and span Non-linearity (BSL)2 Hysteresis and repeatability Ratiometricity Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 4/6 Typ. 1.00 5.0 6.00 Max. 5 1.05 Unit "H2O V 6.10 1.25 1.25 1.25 1.0 %FSS 0.25 7 to 8 V and 8 to 9 V 9 to 12 V 0.5 2.0 20.0 1 10 mA msec V/m June 2006 / 567 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer 163PC01D48-PCB PERFORMANCE CHARACTERISTICS Min. -20 1.59 at -20 cm H2O at 120 cm H2O 5.82 3 (unless otherwise noted, VS = 10.00 V, RL > 100 k, tamb = 25C) Characteristics Operating pressure Zero pressure offset Output Thermal effects (+5 to +45C) Typ. 1.74 1.00 5.97 Max. 120 1.89 Unit cm H2O V 6.12 1.0 1.0 1.0 1.0 %FSS Offset Span Combined offset and span Non-linearity (BSL) Ratiometricity 2 Hysteresis and repeatability 9 to 10 V and 10 to 11 V 7 to 10 V and 11 to 12 V Current consumption (no load) Response time Radiated, radio frequency electromagnetic field immunity (RFI), EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 10 0.15 0.5 2.0 20.0 1 mA msec V/m Specification notes: 1. 2. 3. 4. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Non-linearity - the maximum deviation of measured output at constant temperature, from "Best Straight Line" through three points (offset pressure, full scale pressure and 1/2 full scale pressure). Thermal effects tested and guaranteed in the specified temperature ranges relative to 25C. All specifications shown are relative to 25C. Span is the algebraic difference between lowest and highest specified pressure. June 2006 / 567 5/6 www.sensortechnics.com 160PC...-PCB Series Fully signal conditioned low pressure transducer OUTLINE DRAWING 30.0 port A (high pressure) 14.0 18.3 2 x 5.08 typ. 22.7 1 2 3 12.6 dimensions in mm 31.5 59.8 52.4 10.7 3 terminals 0.56 diam. 3,4 4.8 diam. 3.2 diam. 2 x mounting holes NOM 6.0 mass: 20 g pin 1 2 3 connection +Vs -Vs Vout ORDERING INFORMATION Operating pressure 0 to -1 psid 0 to +1 psid -5 to +5 "H2O 0 to +10 "H2O -2.5 to +2.5 "H2O 0 to +5 "H2O -20 to +120 cm H2O Part number 161PC01D-PCB 162PC01D-PCB 163PC01D36-PCB 164PC01D37-PCB 163PC01D75-PCB 164PC01D76-PCB 163PC01D48-PCB Custom calibrations available Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 6/6 June 2006 / 567 www.sensortechnics.com |
Price & Availability of 163PC01D36-PCB
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |