If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
RoHS Compliant Broadband CATV, Coupler 5-1000MHz Features * * * * * * * Surface Mount Typical Coupling 20dB RoHS* Compliant RoHS version of ELDC-20. 260C Reflow Compatible Available on Tape and Reel. All wires are soldered to the substrate using HMP solder MACP-008125-CK07F0 V1 Schematic Description M/A-COM's MACP-008125-CK07F0 is a high performance 75 Ohm Coupler, in a SM-55 low cost, surface mount package. The MACP-008125-CK07F0 is designed for use in high volume CATV applications. Typical applications include Set-top Boxes, Network Interface Units, Broadband Amplifiers and Headend equipment. Case Style: SM-127 Pin Configuration Pin No. 1 2 3 4 5 6 Function Output Ground, not connected Isolated (external 75 Ohms termination) Coupled Ground Input Part Number MACP-008125-CK07F0 MACP-008125-CK07TB Dimensions in inches [mm] Tolerance: .xx .02, .xxx .010 Ordering Information Package 900 piece reel Customer Test Board Note: Reference Application Note M513 for reel size information. 1 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. * North America Tel: 800.366.2266 * Europe Tel: +353.21.244.6400 * India Tel: +91.80.4155721 * China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. to the product(s) or information contained herein without notice. RoHS Compliant Broadband CATV, Coupler 5-1000MHz Electrical Specifications: TA = 25C, Z0 = 75 1 Parameter Mainline Loss MACP-008125-CK07F0 V1 Test Conditions 5 - 50 MHz 50 - 870 MHz 870 - 1000 MHz 5 - 870 MHz 870 - 1000 MHz 5 - 1000 MHz 5 - 870 MHz 870 - 1000 MHz 5 - 50 MHz 50 - 1000 MHz 5 - 50 MHz 50 - 1000 MHz 5 - 50 MHz 50 - 1000 MHz Units dB dB dB dB dB dB dB dB dB dB dB dB dB dB Min -- -- -- -- -- -- 10 7 20 22 20 22 20 20 Typ 0.6 0.45 0.6 20 20 -- 14 9 22 27 22 28 22 27 Max 0.7 0.65 0.7 0.8 1.0 0.5 -- -- -- -- -- -- -- -- Coupling Coupling Flatness Directivity Input Return Loss Output Return Loss Coupled Return Loss Absolute Maximum Ratings 1,2 Parameter Max Input Power DC current Operating Temperature Storage Temperature Recommended PCB Configuration Absolute Maximum 250mW 30mA -40C to +85C -55C to +100C 1. Exceeding any one or combination of these limits may cause permanent damage to this device. 2. M/A-COM does not recommend sustained operation near these survivability limits. 2 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. * North America Tel: 800.366.2266 * Europe Tel: +353.21.244.6400 * India Tel: +91.80.4155721 * China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. RoHS Compliant Broadband CATV, Coupler 5-1000MHz Typical Performance Curves TA = 25C, Z0 = 75 Main Line Loss 0.0 -0.2 -10 MACP-008125-CK07F0 V1 Return Loss: Input 0 -5 -0.4 dB dB -0.6 -0.8 -1.0 5 204 403 602 801 1000 -15 -20 -25 -30 -35 5 204 403 602 801 1000 Frequency (MHz) Coupling 18 Frequency (MHz) Return Loss: Output 0 -5 -19 -10 dB dB -20 -15 -20 -21 -25 -30 -22 5 204 403 602 801 1000 -35 5 204 403 602 801 1000 Frequency (MHz) Frequency (MHz) Directivity 0 -5 Return Loss: Coupled 0 -5 -10 -15 -20 -25 -30 -35 5 204 403 602 801 100 -10 -15 -20 -25 -30 -35 5 204 403 602 801 1000 dB dB Frequency (MHz) * North America Tel: 800.366.2266 * Europe Tel: +353.21.244.6400 * India Tel: +91.80.4155721 * China Tel: +86.21.2407.1588 Visit www.macomtech.com for additional data sheets and product information. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. 3 Frequency (MHz) ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is considering for development. Performance is based on target specifications, simulated results, and/or prototype measurements. Commitment to develop is not guaranteed. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is not guaranteed. |
Price & Availability of MACP-008125-CK07F0
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |