If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DC-DC Converter UNIT CBR Series ( 2W-3W REGULATED DC-DC CONVERTER ) FEATURES 3000VDC ISOLATION HIGH EFFICIENCY NO HEATSINK REQUIRED LOW COST NO EXTERNAL COMPONENTS REQUIRED UP TO 3W REGULATED OUTPUT POWER DUAL IN LINE PACKAGE 100% BURNED IN LOW NOISE MTBF > 850,000 HOURS OUTPUT SPECIFICATIONS Voltage Setpoint Accuracy Temperature Coefficient Ripple & Noise (20MHz BW) Line Regulation 1 2 INPUT SPECIFICATIONS +/-3% max +/-0.03%/ OC Input Voltage Range Input Filter +/-10% max Pi Network 100mVp-p max +/-0.5% max +/-0.5% max Load Regulation GENERAL SPECIFICATIONS Efficiency Isolation Voltage 3 Short Circuit Protection Short Circuit Restart Current Limit Protection Automatic 60% min 3000 VDC min 9 10 ohms min 25 KHz min 80pF max 850,000 Hours 12.0g-14.4g Non-Conductive Plastic 31.8mm*20.3mm*10.2mm ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Cooling -25 OC to +71 OC -55 OC to +125 OC Free-Air Convection Isolation Resistance Switching Frequency Isolation Capacitance MTBF Weight ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 O Case Material Case Size C UNLESS OTHERWISE NOTED. 1 2 3 High Line to Low Line. Load Regulation is for output load current change from 10% to 100%. For 60 seconds www.Power-Systems.de Page: 1 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CBR Series ( 2W-3W REGULATED DC-DC CONVERTER ) SELECTION GUIDE 2W-3W OUTPUT MODEL NUMBER INPUT (VDC) 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 43.2-52.8 43.2-52.8 43.2-52.8 43.2-52.8 43.2-52.8 OUTPUT (VDC) 5 12 15 +/-12 +/-15 5 12 15 +/-12 +/-15 5 12 15 +/-12 +/-15 5 12 15 +/-12 +/-15 OUTPUT (mA) 400 165 133 +/-83 +/-66 400 165 200 +/-83 +/-100 400 165 200 +/-83 +/-100 400 165 200 +/-83 +/-100 INPUT CURRENT(mA) FULL LOAD NO LOAD 80 80 80 80 80 40 40 45 40 45 20 20 25 20 25 10 10 12 10 12 62 63 63 63 63 63 65 66 65 66 63 65 65 65 65 63 64 64 64 64 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 VOLTAGE VOLTAGE CURRENT EFF (%) ISOLATION (VDC) CBRS-0505-3K CBRS-0512-3K CBRS-0515-3K CBRD-0512-3K CBRD-0515-3K CBRS-1205-3K CBRS-1212-3K CBRS-1215-3K CBRD-1212-3K CBRD-1215-3K CBRS-2405-3K CBRS-2412-3K CBRS-2415-3K CBRD-2412-3K CBRD-2415-3K CBRS-4805-3K CBRS-4812-3K CBRS-4815-3K CBRD-4812-3K CBRD-4815-3K 645 634 634 634 634 264 256 378 256 378 132 128 192 128 192 66 65 97 65 97 Note: Other input to output voltages may be available. Please contact factory. www.Power-Systems.de Page: 2 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CBR Series ( 2W-3W REGULATED DC-DC CONVERTER ) SIMPLIFIED SCHEMATIC SINGLE OUTPUT +Vin OSCILLATOR DRIVER REGULATOR DUAL OUTPUT +Vout +Vin OSCILLATOR DRIVER REGULATOR +Vout Com. -Vout -Vin -Vout -Vin REGULATOR MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS PIN 1&2 10 & 11 12 13 14 15 23 & 24 SINGLE +Vin NO PIN -Vout +Vout NO PIN NO PIN -Vin DUAL +Vin Common NO PIN -Vout NO PIN +Vout -Vin www.Power-Systems.de Page: 3 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CBR Series ( 2W-3W REGULATED DC-DC CONVERTER ) TYPICAL APPLICATIONS SINGLE OUTPUT INPUT +Vin +Vout DUAL OUTPUT INPUT +Vin +Vout OUTPUT OUTPUT LOAD1 DC-DC CONVERTER -Vin -Vout LOAD DC-DC CONVERTER -Vin Common LOAD2 -Vout TYPICAL PERFORMANCE CUREVES Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified. OUTPUT LOAD vs EFFICIENCY 80% OUTPUT LOAD vs OUTPUT VOLTAGE 60% 40% 20% 0% 0% 20% OUTPUT VOLTAGE CHANGE(%) 100% 10% 5% 0% -5% -10% 0% 20% 40% 60% 80% 100% EFFICIENCY(%) SAFE OPERATING AREA 40% 60% 80% OUTPUT LOAD(%) TEMPERATURE DERATING OUTPUT LOAD(%) INPUT VOLTAGE vs EFFICIENCY 100% OUTPUT POWER(%) 125% 100% 75% 50% 25% 0% -25 0 25 50 70 100 EFFICIENCY(%) 80% 60% 40% 20% 0% -10 -5 Nom 5 10 TA(degree C) INPUT VOLTAGE(%) www.Power-Systems.de Page: 4 / 5 Version: 4-Oct-02 DC-DC Converter UNIT CBR Series ( 2W-3W REGULATED DC-DC CONVERTER ) CBR SERIES APPLICATION NOTES: EXTERNAL CAPACITANCE REQUIREMENTS: No external capacitance is required for operation of the CBR series. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 100KHz is required. External output capacitance is not required for operation, however it is recommended that 10uF tantalum and 0.1uF ceramic capacitance be selected for reduced system noise. Additional output capacitance may be added for increased filtering, but should not exceed 220uF. Negative Outputs: A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting -OUT as the negative output. FOR MORE INFORMATION CALL: Power Systems - The Power Solution Ilsfeld-Auenstein ( Germany ) Dornet 8 E-mail: Info@Power-Systems.de Tel: + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 -80 Home Page: www.Power-Systems.de www.Power-Systems.de Page: 5 / 5 Version: 4-Oct-02 |
Price & Availability of CBRD-2412-3K
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |