 Catalog 1308242 Issued 3-03 (PDF Rev. 1-06)
PRODUCTS UNLIMITED
Model 93 - 3100 series
Definite Purpose Contactor 3-pole, 50-60 FLA AC Coil
File E75492 File EN60947-4-1:1991 IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application.
Features
* 3-pole contactors. * Convenient "universal" mounting plate. * Optional interlock/auxiliary switches available.
Environmental Data
Temperature Range: Storage and Operating: -40C - +65C. Flammability: UL 94-HB housing.
Mechanical Data Contact Data @ 25C
Arrangements: 3 Form X (3PST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Contact Termination: Type: Box Lug with dual 0.250" (6.35 mm) quick connects. Wire Size: 14-2 Cu/Al AWG Tightening Torque: 50 in.-lbs. Coil Termination: Dual 0.250" (6.35 mm) quick connects, standard. A 0.250" quick connect and a #6-32 screw, optional. Arc Cover: Standard. Weight: 32 oz. (910 g) approximately
Coil Data @ 25C
Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130C). Duty Cycle: Continuous.
Contact Ratings
Full Load Amps 50 Number of Poles 3 Line Voltage Locked Rotor Amps 300 250 200 Resistive Amps Tungsten/ Ballast Amps - 53 - Voltage 110/120 200/208 240/277 480 600 110/120 200/208 240/277 480 600 Maximum Horsepower Single Phase 3 7.5 10 5 7.5 10 Three Phase 15 15 25 25 25 25 30 30
240 480 600
65 65 65
60
3
240 480 600
360 300 240
75 75 75
- 53 -
Coil Data
Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms 24 182 6 -15 140 132 20 14 2.4 120 93 20 - 70 140 132 20 14 45 208/240 177 40 - 135 140 132 20 14 180 277 235 50-180 140 132 20 14 280 480 374 120 - 286 140 132 20 14 852
Dimensions are shown for
834 reference purposes only.
Dimensions are in inches over (millimeters) unless otherwise specified.
Specifications and availability subject to change.
www.tycoelectronics.com Technical support: Refer to inside back cover.
Catalog 1308242 Issued 3-03 (PDF Rev. 1-06)
PRODUCTS UNLIMITED
Ordering Information
Typical Part No.
B
3100
-
30
I
16
999
1. Series: 3100 = 3-pole, 50-60 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 30 = 3 Form X (3PST-NO-DM) 4.Coil Voltage (50/60 Hz.): I = 24VAC, molded K = 208/240VAC, molded J = 120VAC, molded M = 277VAC, molded W = 480VAC, molded 5.Contact Ratings (Inductive): 16 = 50 FLA 17 = 60 FLA 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options.
Standard part numbers listed below are more likely to be available from stock.
None at present.
Outline Dimensions
3.563 (90.5) 3.10 (78.7) 2.75 (69.9) .218 TYP . (5.537) 2.032 (51.61) .438 (11.12)
Termination
.250 (6.35) .253 (6.43)
3.25 (82.55) 3.75 (95.25) 3.19 (81.03)
Standard on 50-60 FLA Lug accepts 14-2 Cu/Al AWG
2.65 (67 .3)
1.468 (37 .29) 2.242 (56.95)
.250 (6.35)
Shown with Optional Auxiliary Switch
Various interlock / auxiliary switches are available for the Model 93 contactor.
Equipped with 0.250" (6.35) Quick Connect Terminals Factory Modifications Contact Config. NO NC Single unit interlock 1 0 configurations listed. 0 1 Maximum of two. Must 1 1 be same polarity. 2 0 See footnote (1) for ratings. 0 2 2 2 SPDT Circuit 1 1 See footnote (2) for ratings. 2 2 SPDT Dry Circuit, 0.1 amp max. 1 1 Gold Flashed Contacts 2 2 Description Field Added Kits Kit Catalog Number of Number Kits Required 34300-303 1 34300-331 1 34300-332 1 34300-303 2 34300-331 2 34300-332 2 34300-337 1 34300-337 2 34300-341 1 34300-340 1
NORMALLY OPEN -303 STYLE
NORMALLY CLOSED -331 STYLE
NORMALLY OPEN & CLOSED -332 STYLE
SPDT -337 & -341 STYLE
Equipped with #6-32 Screw Terminals & Saddle Clamps Factory Modifications Field Added Kits Description Contact Config. Kit Catalog Number of NO NC Number Kits Required Single unit interlock 1 0 34300-342 1 configurations listed. 0 1 34300-343 1 Maximum of two. Must 1 1 34300-344 1 be same polarity. (note 1) Footnotes: Ratings of Auxiliary Interlocks / Switches (1) Contact Rating Single Circuit NO or NC (2) Contact Rating SPDT (337): and two circuit NO/NC: 10A, 1/3 HP 125 or 250 VAC , 1/2A, 125 VDC; 1/4A, 250 VDC: 120V 240V 480V 600V Break 3.0A 1.5A 0.75A 0.6A 4A 120 VAC on Lamp Load Make 30A 15A 7.5A 6A Continuous 10A 10A 10A 10A
W/ #6-32 SCREW & SADDLE CLAMP -344 STYLE
Dimensions are shown for reference purposes only.
Dimensions are in inches over (millimeters) unless otherwise specified.
Specifications and availability subject to change.
www.tycoelectronics.com Technical support: Refer to inside back cover.
835


▲Up To Search▲   

 
Price & Availability of 3100-30I16999

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X