![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
AC-DC 40-100 Watts ECM Series * * * * * * * xppower.com Compact Size - High Power Density Industrial & Medical Approvals Low Leakage Current Level B Conducted Emissions EN61000-3-2, -3 Compliant Convection-cooled Class II Approved 40-60 W Models Specification Input * 90-264 VAC (120-370 VDC) * 47-63 Hz; 440 Hz * 40 W: 0.4 A max at 230 VAC 60 W: 0.6 A max at 230 VAC 100 W: 0.9 A max at 230 VAC Inrush Current * 40 A max at 230 VAC Earth Leakage Current * <125 A at 115 VAC/60 Hz <210 A at 230 VAC/50 Hz Input Protection * Internal 3.15 A fuse in line and neutral Input Voltage Input Frequency Input Current General Efficiency Isolation * 80-85% depending on model * 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground * 70 kHz typical * 60 W: 6.25 W/In3 100 W: 7.40 W/In3 * 250 kHrs per MIL-HDBK-217F Switching Frequency Power Density MTBF Environmental Operating Temperature * 0 C to +70 C. Refer to derating curves for specific operating limitations. Cooling * Convection & fan-cooled ratings (see derating curves) Operating Humidity * 95% RH, non-condensing Storage Temperature * -20 C to +85 C Operating Altitude * 3000 m Shock * 30 g pk, half sine, 6 axes Vibration * 2 g rms, 5 Hz to 500 kHz, 3 axes Output * See tables * 5% on 3.3 V & 5 V versions, 10% on other single output models and V1 of multi-output models. See note 1 for ECM40/60 models Initial Set Accuracy * 1.0% V1, 5% V2, V3 & V4 Minimum Load * See tables Start Up Delay * 2 s max Start Up Rise Time * 50 ms Hold Up Time * 16/75 ms min at 115/230 VAC Line Regulation * 0.5% Load Regulation * 1% single output models; 3% V1, 5% V2 & V3 ECM40/60 multi-output models. 1% V1 & V2, 5% V3 & V4 ECM100 Cross Regulation * 2% on ECM40/60 only Over/Undershoot * None at turn on/off Transient Response * 4% max. deviation, recovery to within 1% in 500 s for a 25% load change Ripple & Noise * 1% pk-pk, 20 MHz bandwidth Overvoltage Protection * 115-135% Vnom, recycle input to reset Overload Protection * 110-150% on primary power limit, auto recovery Short Circuit Protection * Trip and restart (Hiccup mode) Temperature * 0.05%/C Coefficient Output Voltage Output Voltage Trim EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions * EN60601-1-2, EN61204-3, FCC 20780, EN55022 & EN55011, level B conducted * EN61000-3-2 * EN61000-3-3 * EN61000-4-2, level 2 Perf Criteria A * EN61000-4-3, 10 V/m Perf Criteria A * EN61000-4-4, level 3 Perf Criteria A * EN61000-4-5, level 3 Perf Criteria A * EN61000-4-6, 10 V Perf Criteria A * EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B * EN60950, UL60950, CSA 22.2 601.1, EN60601-1, UL60601-1, CCC pending, contact sales Safety Approvals AC-DC Models and Ratings Max Power Output 1 Voltage +5.0 +7.0 +9.0 +12.0 +15.0 +18.0 +24.0 +33.0 +48.0 +5.0 +5.0 +5.0 +5.0 +5.0 +3.3 +5.0 V V V V V V V V V V V V V V V V Current Min/Max(3) 0.0 A/8.0 A 0.0 A/5.7 A 0.0 A/4.4 A 0.0 A/3.5 A 0.0 A/2.7 A 0.0 A/2.2 A 0.0 A/1.7 A 0.0 A/1.2 A 0.0 A/0.9 A 0.5 A/6.0 A 0.5 A/6.0 A 0.5 A/6.0 A 0.5 A/6.0 A 0.5 A/6.0 A 0.5 A/6.0 A 0.5 A/6.0 A Voltage Output 2 Current Min/Max Voltage Output 3 ECM40 Current Min/Max Model Number(2) ECM40US05^ ECM40US07 ECM40US09^ ECM40US12^ ECM40US15^ ECM40US18 ECM40US24^ ECM40US33 ECM40US48^ ECM40UD21 ECM40UD22 ECM40UT31^ ECM40UT32 ECM40UT33^ ECM40UT34^ ECM40UT35 40 W +12.0 +15.0 +12.0 +24.0 +15.0 +5.0 +3.3 V V V V V V V 0.1 0.1 0.1 0.1 0.1 0.1 0.1 A/2.0 A/1.5 A/2.0 A/1.0 A/1.5 A/1.5 A/1.5 A A A A A A A -12.0 -12.0 -15.0 +12.0 +12.0 V V V V V 0.0 0.0 0.0 0.0 0.0 A/0.5 A/0.5 A/0.5 A/0.5 A/0.5 A A A A A Notes 1. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed. 2. To receive unit with cover fitted, add suffix `-C' to model number. For Class I operation only. 3. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed 40 W. Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Mechanical Details 4.00 (101.6) 3.75 (95.25) 1.20 (30.5) Input Connector J1 Pin 1 Line Pin 2 Neutral 1 J1 2 2.00 (50.8) 1.75 (44.45) 1 J1 mates with Molex housing 43061-0003 & Molex series 5194 crimp terminals Output Connector J2 Single Multi +V1 +V1 +V1 +V1 RTN RTN RTN RTN NC -V3 NC +V2 J2 6 V Adj. 4X o0.156 (3.96) mounting holes o0.312 (7.92) clearance top and bottom 0.14 (3.5) SMD component height Pin 1 2 3 4 5 6 J2 mates with Molex housing 43061-0006 & Molex series 5194 crimp terminals Weight: approx. 0.33 lb (150 g) Notes 1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. Cable harnessess with 300 mm wire available. For single output models, order part number ECM40/60S LOOM. For multi-output models, order part number ECM40/60DT LOOM. 3. Mating connector kit available. Order part number ECM40/60 CONKIT. 4. Covers available. Order part number ECM40/60 COVER^. Cover dimensions are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5) Derating Curves All ECM40 models convection-cooled All ECM40 models with 5 CFM Output Power Output Power 100% 75% 50% 25% 0% 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 100% 75% 50% 25% 0% 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 Note: Derate by 10% if cover is fitted Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. AC-DC Models and Ratings Max Power Output 1 Voltage +5.0 +7.0 +9.0 +12.0 +15.0 +18.0 +20.0 +24.0 +33.0 +48.0 +5.0 +5.0 +5.0 +5.0 +5.0 +3.3 +5.0 V V V V V V V V V V V V V V V V V Current Min/Max(3) 0.0 A/12.00 A 0.0 A/8.60 A 0.0 A/6.70 A 0.0 A/5.00 A 0.0 A/4.00 A 0.0 A/3.30 A 0.0 A/3.00 A 0.0 A/2.50 A 0.0 A/1.80 A 0.0 A/1.25 A 0.5 A/8.00 A 0.5 A/8.00 A 0.5 A/8.00 A 0.5 A/8.00 A 0.5 A/8.00 A 0.5 A/8.00 A 0.5 A/8.00 A Voltage Output 2 Current Min/Max Voltage Output 3 ECM60 Current Min/Max Model Number(2) ECM60US05^ ECM60US07 ECM60US09^ ECM60US12^ ECM60US15^ ECM60US18 ECM60US20 ECM60US24^ ECM60US33 ECM60US48^ ECM60UD21 ECM60UD22 ECM60UT31^ ECM60UT32 ECM60UT33^ ECM60UT34^ ECM60UT35 60 W +12.0 +15.0 +12.0 +24.0 +15.0 +5.0 +3.3 V V V V V V V 0.1 0.1 0.1 0.1 0.1 0.1 0.1 A/3.0 A/2.5 A/3.0 A/1.5 A/2.5 A/1.5 A/1.5 A A A A A A A -12.0 V -12.0 V -15.0 V +12.0 V +12.0 V 0.0 0.0 0.0 0.0 0.0 A/0.5 A/0.5 A/0.5 A/0.5 A/0.5 A A A A A Notes 1. 2. 3. 4. V2 will track a change in V1 by the same percentage change in voltage as V1 is trimmed. To receive unit with cover fitted, add suffix `-C' to model number. For Class I operation only. A 120% peak load can be taken for up to 100 ms with a 25% duty cycle. Average load not to exceed 60 W. 48 V DC input version of 12 V single output model available in OEM quantities (DCM6048S12). Contact sales for details. ^ Available from Newark. See pages 207-208. Available from Farnell. See pages 204-206. Mechanical Details 4.00 (101.6) 3.75 (95.25) 1.20 (30.5) Input Connector J1 Pin 1 Line Pin 2 Neutral J1 mates with Molex housing 43061-0003 & Molex series 5194 crimp terminals. Optional ground (0.25 faston) tab available, contact sales. Output Connector J2 Single Multi +V1 +V1 +V1 +V1 RTN RTN RTN RTN NC -V3 NC +V2 J1 2 1 2.00 (50.8) 1.75 (44.45) 1 J2 6 Pin 1 2 3 4 5 6 V Adj. 4X o0.156 (3.96) mounting holes o0.312 (7.92) clearance top and bottom 0.14 (3.5) SMD component height J2 mates with Molex housing 43061-0006 & Molex series 5194 crimp terminals. Weight: approx. 0.33 lb (150 g) Notes 1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. Cable harnesses with 300 mm wire available. For single output models, order part number ECM40/60S LOOM. For multi-output models, order part number ECM40/60DT LOOM. 3. Mating connector kit available. Order part number ECM40/60 CONKIT. 4. Covers available. Order part number ECM40/60 COVER^. Cover dimensions are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5). 5. Selected single output models available in a 3" x 5" footprint for OEM quantities. Contact sales for details. Derating Curves All ECM60 models convection-cooled All ECM60 models with 5 CFM Output Power Output Power 100% 75% 50% 25% 0% 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 100% 75% 50% 25% 0% 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 Note: Derate by 10% if cover is fitted Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. AC-DC Models and Ratings Single Output Models Output Voltage +3.3 V +5.0 V +7.0 V +9.0 V +12.0 V +15.0 V +18.0 V +24.0 V +33.0 V +48.0 V Minimum 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A 0.0 A Output 1 Current Voltage Min/Max +5.0 V 0.0 A/12.0 A +5.0 V 0.0 A/12.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +3.3 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +3.3 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A +5.0 V 0.5 A/10.0 A Output Current Maximum 15.0 A 15.0 A 11.4 A 8.8 A 7.5 A 6.0 A 5.0 A 4.1 A 3.0 A 2.1 A Output 2 Current Voltage Min/Max +12.0 V 0.0 A/3.0 A +15.0 V 0.0 A/3.0 A +12.0 V 0.0 A/3.0 A +24.0 V 0.0 A/2.0 A +15.0 V 0.0 A/3.0 A +5.0 V 0.0 A/5.0 A +3.3 V 0.0 A/5.0 A +12.0 V 0.0 A/3.0 A +15.0 V 0.0 A/3.0 A +3.3 V 0.1 A/5.0 A +5.0 V 0.1 A/5.0 A +24.0 V 0.1 A/2.0 A +24.0 V 0.1 A/2.0 A +12.0 V 0.1 A/3.0 A +15.0 V 0.1 A/3.0 A with 5 CFM Cooling 20.0 A 20.0 A 14.3 A 11.1 A 8.3 A 6.6 A 5.5 A 4.1 A 3.0 A 2.1 A ECM100 Model Number(1,3) ECM100US03*^ ECM100US05*^ ECM100US07* ECM100US09* ECM100US12*^ ECM100US15*^ ECM100US18* ECM100US24*^ ECM100US33* ECM100US48*^ Multi Output Models Output Power Convection Forced Air Cooled 5 CFM 80 W 100 W 80 W 100 W 75 W 100 W 80 W 100 W 80 W 100 W 65 W 100 W 70 W 100 W 80 W 100 W 70 W 100 W 65 W 100 W 60 W 100 W 80 W 100 W 80 W 100 W 80 W 100 W 80 W 100 W Output 3 Current Voltage Min/Max Output 4 Current Voltage Min/Max Model Number(1,3) ECM100UD21* ECM100UD22* ECM100UT31*^ ECM100UT32* ECM100UT33*^ ECM100UT34*^ ECM100UT35* ECM100UT36* ECM100UT37* ECM100UQ41* ECM100UQ42*^ ECM100UQ43*^ ECM100UQ44* ECM100UQ45*^ ECM100UQ46* -12.0 -12.0 -15.0 +12.0 +12.0 -5.0 -5.0 +12.0 +12.0 +12.0 +15.0 -12.0 -15.0 V V V V V V V V V V V V V 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A/0.8 A A A A A A A A A A A A A -12.0 -12.0 -12.0 -15.0 -5.0 -5.0 V V V V V V 0.0 0.0 0.0 0.0 0.0 0.0 A/0.5 A/0.5 A/0.5 A/0.5 A/0.5 A/0.5 A A A A A A Notes 1. To receive unit with cover fitted, add suffix `-C' to model number. 2. Output 3 available with opposite polarity for OEM quantities. 3. `*' denotes ECM100 models are class I only, contact sales for class II. 4. 48 VDC input version of 12 V single output model available in OEM quantities (DCM10048S12). Available from Farnell. ^ Available from Newark. See pages 204-208. Input Connector J1 Pin 1 Line Pin 2 Neutral J1 mates with Molex housing 43061-0003 and Molex series 5194 crimp terminals. Optional ground (0.25 faston) tab available. 1 Mechanical Details Weight: approx. 0.4 lb (180g) 4.50 (114.3) 4.25 (107.95) 1.20 (30.5) 2.50 (63.5) 2.25 (57.15) 2 J1 1 J2 12 4X o0.156 [3.96] mounting holes o0.312 [7.92] clearance top and bottom V Adj. Cover dimensions are 4.98 x 3.01 x 1.54 (126.5 x 76.4 x 39.0) 0.14 [3.5] SMD component height Pin 1 2 3 4 5 6 7 8 9 10 11 12 Output Connector J2 Single Multi +V1 +V1 +V1 +V1 +V1 +V1 +V1 +V1 V1 RTN RTN V1 RTN RTN V1 RTN RTN V1 RTN RTN NOT USED +V2 NOT USED +V2 NOT USED V3 NOT USED -V4 Notes 1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. Cable harnessess with 300 mm wire available. For single output models, order part number ECM100S LOOM. For multi-outputs, p/n ECM100DT LOOM. J2 mates with Molex housing 43061-0012 and Molex series 5194 crimp terminals. Derating Curves All ECM100 single output models convection-cooled Output Power (W) 100 80 60 40 20 0 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 3. Mating connector kit available for single output models. Order part number ECM100S CONKIT. 4. Covers available. Order part number ECM100 COVER^. 5. Available in a 3" x 5" footprint for OEM quantities. Contact sales for details. All ECM100 models with 5 CFM Note: 1. Derate by 10% if cover is fitted. 2. For multi output convectioncooled operation above +50 C derate linearly to 50% at +70 C. 100% Output Power B C D A A B C D US24-48 US12-18 US05 US03 75% 50% 25% 0% 0 10 20 50 60 30 40 Ambient Temp (C) 70 80 Consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. 22-Oct-07 |
Price & Availability of ECM100UT31
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |