Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing AC-Operated Contactors * AC Operating Mechanism, 3 Main Contacts * Includes Mechanical/Electrical Interlock * Includes Reversing Power Wiring Ratings for Switching AC Motors Ie [A] kW (50 Hz) AC-2, AC-3, AC-4 HP (60 Hz) Auxiliary Contacts Installed per Contactor AC-3 AC-1 230V 400V 415V 1 500V 690V 115V 230V 200V 230V 3 460V 575V NO NC" Catalogue Number ! 104S-C09012C 104S-C09210C 104S-C12012C 104S-C12210C 104S-C16012C 104S-C16210C 104S-C23012C 104S-C23210C 104S-C30010C 104S-C30210C 104S-C37010C 104S-C37210C 104S-C43010C 104S-C43210C 104S-C60010C 104S-C60210C 104S-C72010C 104S-C72210C 104S-C85010C 104S-C85210C 9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 6 5 6 5 6 5 6 5 5 5 5 5 5 5 5 5 5 5 5 5 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 30 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7.5 10 15 30 30 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. Coil Voltage Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09210C becomes Catalogue Number 104S-C09D210C. Standard Coil Voltage 50 Hz 60 Hz 50/60 Hz 12 R Q - 220230 F - KL 24 K J KJ 32 V - - 230240 VA - - 36 W V - 42 X - - 48 Y X KY 100 KP - KP 100110 - KP - 380400 N - - 110 D - KD 120 P D - 400415 G - - 127 S - - 200 KG - KG 200220 L KG KL 208 - H - 208240 - L - Standard Coil Voltage 50 Hz 60 Hz 50/60 Hz 230 - - KF 240 T A KA 277 - T - 347 - I - 380 - E - 400 - - KN 440 B N KB 480 - B - 500 M - - 550 C - - 600 - C - 9-7 Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing DC-Operated Contactors * DC Operating Mechanism, 3 Main Contacts, Line Side Coil Terminations * Includes Mechanical/Electrical Interlock * Includes Reversing Power Wiring Ratings for Switching AC Motors Ie [A] kW (50 Hz) AC-2, AC-3, AC-4 HP (60 Hz) Auxiliary Contacts Installed per Contactor AC-3 AC-1 230V 400V 415V 1 500V 690V 115V 230V 200V 230V 3 460V 575V NO NC" Catalogue Number! 104S-C09012C 104S-C09210C 104S-C12012C 104S-C12210C 104S-C16012C 104S-C16210C 104S-C23012C 104S-C23210C 104S-C30010C 104S-C30210C 104S-C37010C 104S-C37210C 104S-C43010C 104S-C43210C 104S-C60010C 104S-C60210C 104S-C72010C 104S-C72210C 104S-C85010C 104S-C85210C 9 32 3 4 4 4 1/2 1 1/2 2 2 5 7-1/2 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 6 5 6 5 6 5 6 5 5 5 5 5 5 5 5 5 5 5 5 5 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 30 65 10 15 18.5/ 20 22 15 15 2 5 7-1/2 10 20 25 37 65 11 20 18.5 3 5 10 10 25 30 43 85 13 25 22 3 7.5 10 15 30 30 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 ! For other contact configurations, please contact your local Rockwell Automation/Allen-Bradley distributor. " One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. Coil Voltage Suffix Code The Catalogue Number as listed is incomplete. Select a coil voltage code from the table below to complete the Catalogue Number. Example: 120V 60 Hz: Catalogue Number 104S-C09210C becomes Catalogue Number 104S-C09ZJ210C. DC Voltage 104S-C09...C43 104S-C60...C85 Standard with Integrated Diode with Integrated Diode DC Voltage 104S-C09...C43 104S-C60...C85 Standard with Integrated Diode with Integrated Diode 9 ZR -- DR 80 ZE -- DE 12 ZQ -- DQ 110 ZD -- DD 24 ZJ DJ DJ 115 ZP -- DP 36 ZW -- DW 125 ZS -- DS 48 ZY -- DY 220 ZA -- DA 60 ZZ -- DZ 64 ZB -- DB 230 ZF -- DF 72 ZG -- DG 250 ZT -- DT 9-8 |
Price & Availability of 104S-C16X012C
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |