Rev. B DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply FEATURES Splash Proof Single Output 3 Year Warranty Optional Output Connectors Over Temperature Detection A & C Types: Class I Insulation 3 Types of Inlet Connectors Available Over Voltage and Over Load Protection Wide Input Voltage 90 to 264VAC, 47~63Hz B Type: Class II Insulation (Double Insulation) Output Voltages Available from 5VDC to 36VDC Type A Type B Type C SPECIFICATIONS: DTMPU15 Series SPECIFICATION INPUT (Vin) Operating Voltage Range Input Frequency Input Current (Low Line) Input Current (High Line) Inrush Current (Low Line) Inrush Current (High Line) Safety Ground Leakage Current Start-Up Time OUTPUT (Vo) Output Voltage Range Load Regulation Line Regulation Output Power Range Output Current Range Ripple & Noise (peak to peak) Transient Response Hold-Up Time PROTECTION (1) Over Voltage Protection (1) Over Current Protection GENERAL Efficiency Dielectric Withstanding Voltage For Primary to Secondary Dielectric Withstanding Voltage For Primary to Ground (A & C Types Only) Isolation Resistance Power Consumption (No Load) ENVIRONMENTAL Operating Temperature Storage Temperature Relative Humidity Temperature Coefficient Thermal Shutdown by Junction (1) Temperature Controller MTBF PHYSICAL Weight Dimensions Input Inlet Warranty SAFETY EMI Requirements for EN55022 EMI Requirements for FCC Part-15, FCC Part 18 All specifications are based on 25 C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. o TEST CONDITIONS Min 90 47 Nom Max 264 63 0.33 0.18 16 30 0.3 1 Unit VAC Hz A A A A mA s VDC % % W A % ms ms % % % VDC VDC Io = Full Load, Vin = 115VAC Io = Full Load, Vin = 230VAC Io = Full Load, 25C, Cool Start, Vin = 115VAC Io = Full Load, 25C, Cool Start, Vin = 230VAC Io = Full Load, Vin = 240VAC Io = Full Load, Vin = 100VAC 0.25 0.17 14 28 0.5 Vin = 230VAC Io = Full Load Vin = 90 to 264VAC Full Load, Vin = 90VAC Io = Full Load to Half Load, Vin = 100VAC Io = Full Load, Vin = 110VAC See Rating Chart 3 5 0.5 1 0 15 See Rating Chart 0.5 1 4 10 16 1 112 110 132 150 85 Io = Full Load, Vin = 230VAC Primary to Secondary Primary to Ground Test Voltage = 500VDC No Load, Vin = 230VAC Derate linearly from 100% Load at 50C to 50% load at 70C 73 5600 2800 50 0 0 -40 5 -0.04 -20 100,000 0.4 50 0.5 70 85 95 +0.04 +125 M W C C % %/C C hours All Outputs The parameter is not subject to production test-verified by design/characterization of integrated controller. Operating temperature at 25C, calculated per MIL-HDBK-217F Approximately 170 grams A Type: 4.11 x 1.65 x 1.22 inches B & C Types: 3.90 x 1.65 x 1.22 inches IEC-320-C14, IEC-320-C8, IEC-320-C6 3 years Vin = 230VAC, 50Hz Vin = 120VAC, 60Hz B B Class Class (1) When the power system interruption is isolated, the product would re-start after recovering by hand. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Rev. B DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply OUTPUT VOLTAGE/ CURRENT RATING CHART Model Number DTMPU15x-102 DTMPU15x-103 DTMPU15x-104 DTMPU15x-105 DTMPU15x-106 DTMPU15x-107 DTMPU15x-108 DTMPU15x-109 DTMPU15x-110 Output Voltage 5 VDC 7 VDC 9 VDC 12 VDC 16 VDC 18 VDC 24 VDC 30 VDC 36 VDC Output Current 2.60A 1.85A 1.66A 1.25A 0.93A 0.83A 0.62A 0.50A 0.41A Total Regulation (2) 5% 5% 5% 5% 5% 5% 3% 3% 3% Maximum Output Power 13W 13W 15W 15W 15W 15W 15W 15W 15W NOTES 1. The DTMPU15 Series is designated as DTMPU15x-y where x represents the type of AC input inlet connector which can either be A (IEC-320-C14), B (IEC-320-C8), or C (IEC-320-C6); y can be 102, 103, 104, 105, 106, 107, 108, 109, or 110 for output voltage. 2. Models DTMPU15-102, 103, and 105 needs to use AWG#16/4FT output cable in order to meet the total regulation. Models DTMPU15-104, 106~110 needs to use AWG#18/4FT output cable in order to meet the total regulation. The regulation and efficiency will change if a different output cable is used. 3. Optional output connectors are available (see "DC Output Plug Selector List" link located at the bottom of the "Desktop" category page). DERATING CURVE Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Rev. B DTMPU15 Series 15 Watt Single Output For Medical Equipment AC/DC Desktop Power Supply MECHANICAL DRAWINGS Unit: inches [mm] TYPE A TYPES B & C Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 |
Price & Availability of DTMPU15
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |