Part Number Hot Search : 
MMBD7 DW1T1 A8600 2SK2496 CXA18 B3943 MTD5N05 UM805
Product Description
Full Text Search
 

To Download GD2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Interlock Switches
Non contact Switches
Ferrogard GD2 Specifications
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems CE marked for all applicable directives and cULus Safety Auxiliary 12mm (0.47in) 15mm (0.59in) 23mm (0.91in) 26mm (1.02in) 3.0ms 0.5ms 2.1ms 0.3ms 0.7ms 0.7ms 15m 10m 0.65pF 0.2pF 1x106 1x106
Category
Approvals Reed Contacts Operating Distance - Make Operating Distance - Break Closing Time Dropout Time Bounce Time Initial Contact Resistance Initial Capacitance, Terminal to Terminal Initial Insulation Resistance, Terminal to Terminal Safety Contact Switching Capability
Description
The Ferrogard range of magnetically actuated safety switches offers Non contact reliability together with tolerance to misalignment. They are designed to be installed so that when a guard door is opened, the action of the magnetic actuator being removed from the switch opens the N.C. safety contacts which are intended for the isolation of control power to a machine primary control element. The GD2 version has a stainless steel housing for added protection against inadvertent impacts to the housing. The contacts are completely sealed to meet IP68 (NEMA6P) requirements, making them ideal for wet environments. The GD2 also has a wider temperature range than the plastic Ferrogard switches, making them useful in a wider range of applications. Unlike some magnetic switches, the Ferrogards have protected safety contacts to help ensure that they do not fail to danger. In addition, some versions have independent auxiliary signal contacts to indicate the machine and guard condition. All Ferrogards have internal non-resettable overload protection on the safety contact. They should be protected by an external fuse rated as shown in the specifications table.
AC 250V AC 2A max DC 24V DC 1A max Safety Contact External Fusing AC <1.6A quick blow DC <0.8A quick blow Auxiliary Contact Switching Capability Min Initial Breakdown Voltage Environmental Cable 300V DC, 250V AC, 0.5A including inrush. 15VA/10W suitable for AC/DC circuits 600V AC 600V AC
IP68 (NEMA 6P) 0.50mm2 (20 AWG) 7 wire Flexible thermoplastic elastomer Jacket OD 8mm (0.2in) -25C to +125C (-13 to +257F) Stainless Steel; BS3146 ANC4B (316L) Any Position; M4 mounting security screws included
Features
* * * * * * Non contact actuation High tolerance to misalignment High switching current (up to 2A AC, 1A DC) Wide Temperature Range (-25C to +125C) Stainless Steel Housing Various Contact Arrangements
Operating Temperature Case Material Mounting
Weight (not including cable) Sensor Actuator 156g (0.34lbs) 168g (0.37lbs) Electrical Life Mechanical Life Vibration Shock 1 x 106 at rated load 10 x10 6 7-15g, 10 to 200Hz 50g
3-50
Interlock Switches
Non contact Switches
Ferrogard GD2 Product Selection
Safety Contact Switching Capability 250V AC 2A Safety Contacts Auxiliary Contacts 1 N.C. 1 N.O. None 2 N.C. 1 N.O. 1 N.C. None 2 N.C. 1 N.O. Connection Housing Material Type FRS 2 GD2 FRS 20 GD2 FRS 21 GD2 FRS 2 GD2 FRS 20 GD2 FRS 21 GD2 Catalogue Number 440N-G02112 440N-G02113 440N-G02117 440N-G02118 440N-G02119 440N-G02123
3m Cable
Stainless Steel
24V DC 1A
Note: Contacts are described with the guard door closed, that is, actuator in place. Switch is shipped with complete actuator.
Accessories
Description Actuator Page Number -- Catalogue Number 440N-A02128
Approximate Dimensions--mm (inches)
Dimensions are not intended to be used for installation purposes.
Switch 4.4 (0.17) 8 (0.31) 62.5 (2.46) 11.5 (0.45) 8 (0.31) 6 (0.24) 39.25 (1.55) 39.25 (1.55) Actuator 33.5 (1.32) 8 (0.31) 16.75 (0.66) 39.25 (1.55) 39.25 (1.55) 16 (0.63)
78.5 (3.09)
5 (0.20)
7 (0.28) 16.75 (0.66)
19.5 (0.77) 16 (0.63) 33.5 (1.32) 7 (0.28) 19.5 (0.76)
62.5 (2.46)
11.5 (0.45)
4.4 (0.17)
Typical Wiring Diagrams
FRS 2 Red Blue Yellow Green FRS 20 Red Blue Black White Note: Unit must be to a grounded to a grounded metal frame or grounded via the field wiring per NEC requirements. Safety N.C. Fuse Externally Safety N.C. Fuse Externally Aux. N.O. Safety N.C. Fuse Externally FRS 21 Blue Red Black White Yellow Green Aux. N.O. Safety N.C. Fuse Externally Safety N.C. Fuse Externally
Application Details
See page 3-54 for operating principles and mounting examples.
78.5 (3.09)
5 (0.20)
3-51


▲Up To Search▲   

 
Price & Availability of GD2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X