![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
LF100D Series Ultra-Miniature, 1W Dual Output SMT DC/DC Converters Electrical Specifications Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: * 1W Output Power * Ultra-Miniature SMT Case * 1,000 VDC Isolation * 5V, 12V & 24V Inputs * -40C to +85C Operation * 12 Standard Models * 2.0 MH MTBF Minimum * Industry Standard Pin-Out Parameter Input Voltage Range Reverse Polarity Input Current Input Filter Conditions 5 VDC Input 12 VDC Input 24 VDC Input Min. 4.5 10.8 21.6 Typ. 5.0 12.0 24.0 Max. 5.5 13.2 26.4 0.3 Units VDC A Capacitor Conditions Dual Output, Balanced Load For Vin Change of 1% Min. Typ. 1.0 0.1 1.2 60 Over Line, Load & Temp. 120 0.01 Momentary (0.5 Sec.) Conditions 60 Seconds 500 VDC 100 kHz, 1V 50 Conditions Ambient Case Min. -40 -40 -40 Free Air Convection RH, Non-condensing 95 % Min. 1,000 1,000 40 100 Typ. +25 100 140 Max. +85 +90 +125 Typ. Max. Units VDC M pF kHz Units C C C 0.02 Max. 3.0 1.0 1.5 120 150 5 Units % % % mV P - P mV P - P mv rms % %/C Output Parameter Output Voltage Accuracy Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit See Model Selection Guide RoHS Compliant General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Physical Case Size Case Material Weight 0.60 x 0.31 x 0.26 Inches (15.24 x 8.0 x 6.7 mm) Non-Conductive Black Plastic (UL94-V0) 0.05 Oz (1.5g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 5 VDC Input Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. 2.0 Min. -0.7 -0.7 -0.7 Typ. Max. 9.0 18.0 30.0 260 450 C mW VDC Typ. Max. Units MHours Units Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Input Model Number LF101D LF102D LF103D LF104D LF111D LF112D LF113D LF114D LF121D LF122D LF123D LF124D Voltage (VDC) Nominal 5 5 5 5 12 12 12 12 24 24 24 24 Range 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 Load Voltage Current Current Regulation Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) Current (mA) 267 260 255 251 111 109 105 103 56 55 53 52 30 30 30 30 15 15 15 15 9 9 9 9 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 100.0 55.0 42.0 33.0 100.0 55.0 42.0 33.0 100.0 55.0 42.0 33.0 2.0 1.0 0.8 0.7 2.0 1.0 0.8 0.7 2.0 1.0 0.8 0.7 10 10 8 7 8 8 5 5 8 8 5 5 Output Efficiency (%, Typ) 75 76 79 79 75 76 80 80 74 75 79 79 Fuse Rating Slow-Blow (mA) 500 500 500 500 200 200 200 200 100 100 100 100 Notes: 1. Load regulation is measured for an output change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 F ceramic capacitor be placed from each output to common. For noise sensitive applications, the use of 0.47 F capacitors will reduce the output ripple. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 5V input units a 2.2 F is recommended, for 12V input units, a 1.0 F, and for 24V input units, a 0.47 F. 5. The outputs of these units may be connected to provide a 10 VDC, 18 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the ouput common. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Board Layout Derating Curve Capacitive Load F Max 33 Pin Connections Pin 1 2 3 4 5 Description -Vin +Vin NA Common -Vout Pin 6 7 8 9 10 Description NA +Vout NA NA NA MicroPower Direct www.micropowerdirect.com Mechanical Dimensions - 5/12V Input Mechanical Dimensions - 24V Input Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) * Pin 1 is marked by a "dot" or indentation on the unit 292 Page Street, STE D, Stoughton, MA 02072 * TEL: (781) 344-8226 * FAX: (781) 344-8481 * E-Mail: sales@micropowerdirect.com MPD also offers a full range of compact open frame, enclosed, U-chassis and DIN Rail AC/DC power supplies. Our very wide range of models offers: * * * * * * * * * * Nearly 2,000 Standard Models 10W to 1,000W Output Power 1 to 4 Outputs Universal Inputs Power Factor Correction International Approvals (Including Medical) Many Form Factors & Mechanical Options Robust Filtering & Protection Circuits High MTBFs Low Cost Call us today. Whether you need a ruggedized unit for a critical industrial application or a very low cost basic model; we have the right AC/DC power supply for your application requirement. Below is a sampling of the products we offer. Series Description Power Input Output Approvals Size HF-15W-SPL Miniature, single output openframe series 15W Universal 85 - 264 VAC 5V to 48V UL, cUL, CE 3.9 x 1.8 x 0.9 (100 x 46 x 22) RL0402U Medically approved 400W series in u-chassis or enclosed with built in fan. 400W Universal 90-264 VAC Active PFC Single & Dual Models 2V to 58V UL, cUL, TUV, CE (Medical) 8 x 5 x 1.6 (203.2 x 127 x 40.6) AD1072F Very low cost Single output 72W DIN Rail mount supplies 72W Universal 100 - 240 VAC 12V to 48V CE 4.7 x 4.3 x 2.2 (121 x 110 x 56) MPA320F Compact 320W supplies include a cover with built in fan 320W Auto-Ranging 90-132 VAC 185 - 264 VAC Passive PFC Single & Dual Models 2V to 60V UL, cUL, TUV, CE 6 x 4 x 1.5 (152.4 x 101.6 x 38.1) HF60W-xL Very low cost 60W enclosed series. 60W Universal 85 - 264 VAC Single, Dual & triple output models 5V to 48V UL, cUL, CE 6.3 x 3.8 x 1.5 (160 x 98 x 39) This is a just a small sampling of our AC/DC product range. Whatever your application requirements, give us a call or go to our website at www.micropowerdirect.com. If we don't have a standard product that fits your need, ask about product modifications. And don't forget, we also offer well over 2,000 standard DC/DC converters. Call today. MicroPower Direct www.micropowerdirect.com 292 Page Street, STE D, Stoughton, MA 02072 * TEL: (781) 344-8226 * FAX: (781) 344-8481 * E-Mail: sales@micropowerdirect.com |
Price & Availability of LF114D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |