  Datasheet File OCR Text:
 3.0
PD035VL1
D035VL1
November 23
PD035VL1
Revision History
Rev. 0.1
Eng.
Issued Date Oct.31 ,2006
Revised Preliminary 0.1ver
Contents
1.0
Feb,13,2007
2.0
Nov.13,2007
Release version Modify Page 23: 16 Delete carton and change packing
3.0
Nov.23,2007
Modify Page23 12. Reliability Test
Low Temperature Operation Test : -20
change to -30
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:2
PD035VL1
TECHNICAL
SPECIFICATION
CONTENTS
NO.
-
ITEM
Cover
PAGE
1
-
Revision History
2
-
Contents
3
1
Application
4
2
Features
4
3
Mechanical Specifications
4
4
Mechanical Drawing of TFT-LCD module
5
5
Input Terminals
7
6
Absolute Maximum Ratings
9
7
Electrical Characteristics
9
8
Pixel Arrangement
11
9
Display Color and Gray Scale Reference
12
10
Block Diagram
13
11
Interface Timing
14
12
Power On Sequence
17
13
14
Optical Characteristics Handling Cautions
18
22
15
Reliability Test
23
16
Packing Diagram
24
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:3
PD035VL1
1.Application This data sheet applies to a color TFT LCD module, PD035VL1 The module applies to OA product, GPS, which require high quality flat panel display. If you must use in high reliability environment can't over reliability test condition. If you use PD035VL1, Prime View advises your system sides must use PVI-2002A(2005/8 new product change to PVI-2003A) which one generates signal to control PD035VL1 2. Features . Amorphous silicon TFT LCD panel with back-light unit . Pixel in stripe configuration . Thin and light weight . Display Colors 262144 colors . Optimum Viewing Direction 6 o'clock . LVDS transmission interface 3. Mechanical Specifications
Parameter Screen Size Display Format Display Colors Active Area Pixel Pitch Pixel Configuration Back-light Outline Dimension Weight Surface treatment Display mode Specifications 3.5 (diagonal) 640 (R, G, B) 480 262,144 72.00 (H) 52.56 (V) 0.1125 (H) 0.1095 (V) Stripe Unit inch dot
mm mm
6-LED
85.2 (W) 66.45(H) 8.45 (D) (Typ.) 78 5 AG Normally white mm g
Gray scale inversion direction
6 o'clock [Note 13-2]
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:4
PD035VL1
4.Mechanical Drawing of TFT-LCD Module Outline Drawing : Front View (unit mm)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:5
PD035VL1
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:6
PD035VL1
5.Input Terminals
5-1) TFT-LCD Panel Driving Connector type: DF19K-20P-1H(56)(HRS) Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Symbol Vcc Vcc GND GND INOINO+ GND IN1IN1+ GND IN2IN2+ GND CLKCLK+ GND NC NC GND GND Function +3.3V Power Supply +3.3V Power Supply Ground Ground LVDS receiver signal channel 0 LVDS receiver signal channel 0 Ground LVDS receiver signal channel 1 LVDS receiver signal channel 1 Ground LVDS receiver signal channel 2 LVDS receiver signal channel 2 Ground LVDS receiver signal clock LVDS receiver signal clock Ground No connection No connection Ground Ground Remark
LVDS Interface Block Diagram
R0~R5 G0~G5 B0~B5 H sync V sync
DENB
T I N 0~ T I N 5
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:7
Graphic Controller Circuit
T I N 6~ T I N 1 1 T I N 12~ TI N 17 T I N 18 T I N 19 T I N 20 T CL K IN
I N 0IN0+ I N 1IN1+ I N 2IN2+ CLK-
TTL parallel to LVDS
LCD Internal Circuit
LVDS interface
Signal Processor
D ata
C ontrol & data
CLK IN
PLL
CLK+
T H C 63L V D M 63 A C ustom er system side
L C D co ntro ller
PD 03 5V L 1
PD035VL1
Recommended Transmitter (THC63LVDM63A Thine) to PD035VL1 interface Assignment: Input terminal of THC63LVDM63A To PD035VL1 Output signal interface terminal symbol (Symbol) Graphic controller output signal
Symbol TIN0 TIN1 TIN2 TIN3 TIN4 TIN5 TIN6 TIN7 TIN8 TIN9 TIN10 TIN11 TIN12 TIN13 TIN14 TIN15 TIN16 TIN17 TIN18 TIN19 TIN20 CLK in
No. 44 45 47 48 1 3 4 6 7 9 10 12 13 15 16 18 19 20 22 23 25 26
Symbol R0 R1 R2 R3 R4 R5 G0 G1 G2 G3 G4 G5 B0 B1 B2 B3 B4 B5 Hsync Vsync DENB CLK
Function Red pixel data (LSB) Red pixel data Red pixel data Red pixel data Red pixel data Red pixel data(MSB) Green pixel data (LSB) Green pixel data Green pixel data Green pixel data Green pixel data Green pixel data(MSB) Blue pixel data(LSB) Blue pixel data Blue pixel data Blue pixel data Blue pixel data Blue pixel data(MSB) Horizontal Synchronous Signal Vertical Synchronous Signal Compound Synchronization signal Data sampling clock
Tout0-
No.5 : IN0-
Tout0+
No.6 : IN0+
Tout1-
No.8 : IN1-
Tout1+
No.9 : IN1+
Tout2-
No.11 : IN2-
Tout2+
N0.12 : IN2+
TCLK outTCLK out+
No.14 : CLK No.15 : CLK+
DENB input signal.
If customer wanted to off the DENB mode , you must keep the DENB always High or Low.
(tc: the period of sampling clock)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:8
PD035VL1
6. Absolute Maximum Ratings : The followings are maximum values , which if exceeded, may cause faulty operation or damage to the unit.
Parameters Supply Voltage Symbol VCC MIN. -0.3 MAX. +4.0 GND=0V, Ta=25 Unit Remark V
7.Electrical Characteristics
7-1) Recommended Operating Conditions: Item Symbol Supply Voltage Vcc Current Dissipation Icc LVDS Differential input high threshold VTH LVDS Differential input low threshold VTL Vcom Voltage Vcom Ta = 25 Remark
Min. 3.0 -100 -
Typ. 3.3 455.4 2.6
Max. 3.6 496.8 100 -
Unit V mA mV
Note 7-1
V
Note 7-1 : To test the current dissipation of VCC using the "color bars" testing pattern shown as below
1
2
3
4
5
6
7
8
1. 2. 3. 4. 5. 6. 7. 8.
White Yellow Cyan Green Magenta Red Blue Black
Idd current dissipation testing pattern
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:9
PD035VL1
7-2) Recommended driving condition for LED backlight GND = 0 V Ta = 25
Parameter
Symbol
Min
TYP
MAX Unit
Supply voltage of LED backlight
VLED
-
-
(11.4)
V
Remark Note 7-2
Supply current of LED backlight
ILED1
ILED2
-
20
-
mA
Note 7-3
Backlight Power Consumption
PLED
-
-
456
mW
Note 7-4
Note 7-2 : ILED= 20mA,constant current Note 7-3 : The LED driving condition is defined for each LED module. (3 LED Serial) Input current = 20mA * 2. Note 7-4 : PLED = VLED * ILED1 + VLED * ILED2 .
7-3) Power Consumption Parameters Total Power Consumption Symbol Typ. 1.37 Max. 1.65 Unit W Remark
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:10
PD035VL1
8. Pixel Arrangement
The LCD module pixel arrangement is the stripe.
R G B R G B R G B 1 st Line
RGB
R G B R G B 2 nd Line
R G B 3 rd Line
RGB
RGB
1 st Pixel 1 Pixel = R G B
640 th Pixel
RGB
478 th Line 479 th Line 480 th Line
RGB
RGB
RGB
RGBRGB
RGBRGBRGB
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:11
PD035VL1
9. Display Color and Gray Scale Reference
Input Color Data Green
Color
Red
Blue
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Basic Colors
Black Red (63) Green (63) Blue (63) Cyan Magenta Yellow White Red (00) Red (01) Red (02) Darker
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 1
0 1 0 0 0 1 1 1 0 1 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
Red
Brighter Red (61) Red (62) Red (63) Green (00) Green (01) Green (02) Darker
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 1 1 0 0 0
1 0 1 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 1
0 0 0 0 1 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Green
Brighter Green (61) Green (62) Green (63) Blue (00) Blue (01) Blue (02) Darker
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
1 1 1 0 0 0
0 1 1 0 0 0
1 0 1 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 1
0 0 0 0 1 0
Blue
Brighter Blue (61) Blue (62) Blue (63)
000000000000111101 000000000000111110 000000000000111111
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:12
PD035VL1
10. Block Diagram 10-1) TFT-module Block Diagram
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:13
PD035VL1
11. Interface Timing 11.1) Timing Parameters Symbol Min. Typ. Max. Unit Remark
Power supply
VCC
3.0
3.3
3.6
V
CLK
Frequency
1/tc
-
25
-
MHz
tc
-
40
-
ns
HSYNC Period
Display period
Hp
-
32
-
us
-
800
-
tc
Hdp
-
640
-
tc
Pulse width
Hpw
-
96
-
tc
Back-porch
Hbp
-
46
-
tc
Front-porch
Hfp
-
18
-
tc
Hpw+Hbp
-
142
-
tc
Hsync-CLK
Hhc
10
-
Tc-10
ns
Vsync-Hsync
Hvh
0
0
200
tc
VSYNC Period
Display period
Vp
-
16.8
-
ms
-
525
-
Hp
Vdp
-
480
-
Hp
Pulse width
Vpw
-
2
-
Hp
Back-porch
Vbp
-
33
-
Hp
Front-porch
Vfp
-
10
-
Hp
Vpw+Vbp
-
35
-
Hp
DENB
Horizontal scanning period
T1
-
800
-
tc
Horizontal display period
T2
-
640
-
tc
Vertical display period
T3
-
480
-
T1
Frame cycling period
T4
520
525
800
T1
R,G,B
CLK-DATA
Dcd
10
-
-
ns
DATA-CLK
Ddc
8
-
-
ns
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:14
PD035VL1
11.2) The Timing Diagram
a. Input signal range a.1
tc
Dcd Ddc
R05-R00 G05-G00 B05-B00
DENB
a.2 HSYNC timing Hp HSYNC Hpw
Hdp Hbp R,G,B Vaild data Hfp
a.3 CLK,HSYNC relationship
CLK
Hhc
HSYNC
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:15
PD035VL1
a.4 HSYNC, VSYNC relationship
a.5 VSYNC timing
DENB
a.6 DENB timing
Line 1
Line 480
Line 1
Line 2
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:16
PD035VL1
12. Power On Sequence
VCC 3.0V Logic Signal 3.0V
0.3V
t1
t2
t3
Backlight
OFF
ON
OFF
10ms
10ms
1. 0 2. 0 3. 0
t1 t2 t3
20ms 50ms 1s
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:17
PD035VL1
13. Optical Characteristics
13-1) Specification: Parameter Horizontal Symbol Condition 21, 22 12 (to12o'clock) CR 10 11 (to 6 o'clock) CR Tr =0 Tf L =0 U =0 =0 x y Ta=25 MIN. TYP. MAX. 45 50 Unit deg Ta=25 Remarks
Viewing Angle
10
15
-
deg
Vertical
Note 13-2
30
35
-
deg
Contrast Ratio
Response time
Rise Fall
Brightness Uniformity
Cross Talk
White Chromaticity
LED Life Time
200 400 15 25 200 250 70 75 0.28 0.31 0.30 0.330 20000 30000
30 50 3.5 0.34 0.36 -
ms ms
Note 13-4
Note 13-3
cd/
% % hrs
Note 13-1 Note 13-5 Note 13-6
Note 13-1
Note 13-7
All the optical measurement shall be executed 30 minute after backlight being turn-on. The optical characteristics shall be measured in dark room (ambient illumination on panel surface less than 1 Lux). The measuring configuration shows as following figure.
Photometer (TOPCON BM-5A or BM-7 fast)
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:18
500 mm +/- 50 mm
Field = 1
TFT-LCD module
Optical characteristics measuring configuration
PD035VL1
Note 13-1: 1.Topcon BM-5A or BM-7 fast luminance meter 1 field of view is used in the testing (after 30
minute operation).
Note 13-2: The definitions of viewing angles are as follow
Note 13-3: Definition of Response Time Tr and Tf:
White Black White
100% 90%
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:19
Brightness
10% 0%
Tr Tf
PD035VL1
Note 13-4: The definition of contrast ratio
=
Note 13-5 : The uniformity of LCD is defined as The Minimum Brightness of the 9 testing Points U= The Maximum Brightness of the 9 testing Points Luminance meter : BM-5A or BM-7 fast (TOPCON) Measurement distance : 500 mm +/- 50 mm Ambient illumination : < 1 Lux Measuring direction : Perpendicular to the surface of module
The test pattern is white (Gray Level 63).
1 /6
2 /6
2 /6 1 /6
1 /6
2 /6
2 /6
1 /6
Note 13-6 : Cross Talk (CTK) =
YA-YB YA YA : Brightness of Pattern A YB : Brightness of Pattern B
100%
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:20
PD035VL1
Pattern A
(Gray Level 31)
Pattern B
(Gray Level 31, central black box exclusive)
YA
YB
1/3 1/3 1/3 1/3
: Testing Point (A and B are at the same point.)
1/3
1/3 Black (Gray Level 0)
Note 13-7: The "LED Life time " is defined as the module brightness decrease to 50% original Brightness that the ambient temperature is 25 and ILED =20mA.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:21
PD035VL1
14. Handling Cautions 14-1) Mounting of module a) Please power off the module when you connect the input/output connector. b) Polarizer which is made of soft material and susceptible to flaw must be handled carefully. c) Protective film (Laminator) is applied on surface to protect it against scratches and dirt's. It is recommended to peel off the laminator before use and taking care of static electricity. 14-2) Precautions in mounting a) When metal part of the TFT-LCD module (shielding lid and rear case) is soiled, wipe it with soft dry cloth. b) Wipe off water drops or finger grease immediately. Long contact with water may cause discoloration or spots. c) TFT-LCD module uses glass which breaks or cracks easily if dropped or bumped on hard surface. Please handle with care. d) Since CMOS LSI is used in the module. So take care of static electricity and earth yourself when handling. 14-3) Adjusting module a) Adjusting volumes on the rear face of the module have been set optimally before shipment. b) Therefore, do not change any adjusted values. If adjusted values are changed, the specifications described may not be satisfied. 14-4) Others a) Do not expose the module to direct sunlight or intensive ultraviolet rays for many hours. b) Store the module at a room temperature place. c) The voltage of beginning electric discharge may over the normal voltage because of leakage current from approach conductor by to draw lump read lead line around. d) If LCD panel breaks, it is possibly that the liquid crystal escapes from the panel. Avoid putting it into eyes or mouth. When liquid crystal sticks on hands, clothes or feet. Wash it out immediately with soap. e) Observe all other precautionary requirements in handling general electronic components. f) Please adjust the voltage of common electrode as material of attachment by 1 module.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:22
PD035VL1
15. Reliability Test
No 1 Test Item High Temperature Storage Test Test Condition Ta = +80 , 240 hrs
2 3 4
Low Temperature Storage Test
Ta = -30
, 240 hrs
5
High Temperature Operation Test Low Temperature Operation Test High Temperature & High Humidity Operation Test
Ta = +70 Ta = -30
, 240 hrs , 240 hrs
Ta = +60
, 90%RH, 240 hrs
6
Thermal Cycling Test (non-operating)
Shock Test (non-operating)
-25 30 min
+70 , 200 Cycles 30 min
100G, 6ms Direction: X, Y, Z Cycle: 3 times Frequency 10 ~ 55 HZ Amplitude 1 mm Sweep time: 11 mins
7
Vibration Test 8 (non-operating)
Test Period: 6 Cycles for each direction of X, Y, Z
Contact mode: 9 Electrostatic Discharge Test (non-operating)
8KV,10times/point , 5 points/panel face Air mode: 150pF, 330Air : 15KV
Ta: ambient temperature Note: The protective film must be removed before temperature test. [Criteria] In the standard conditions, there is not display function NG issue occurred. (including : line defect ,no image), All the cosmetic specification is judged before the reliability stress.
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:23
PD035VL1
16. Packing Diagram
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:24
PD035VL1
The information contained herein is the exclusive property of Prime View International Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of Prime View International Co., Ltd. Page:25


▲Up To Search▲   

 
Price & Availability of PD035VL1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X