 Preset counters electromechanic
1 preset, subtracting, permanent precontact Display 5 digits, manual/electric reset
FS309, FS319, FS329
Features - Preset counter with one preset - Subtracting - Display 5-digits - Manual and electric reset
FS309 - Socket box Technical data - electrical ratings Voltage supply 24/110 VAC 10 % (50/60 Hz) 230 VAC +6/-10 % (50/60 Hz) 24 VDC 10 % <48 % 50 / 60 Hz 1:1 100 million impulses 1 preset Change-over contact by microswitch, one-pole 100 VA / 30 W 1 million switching cycles Recommended for inductive load
Subject to modification in technic and design. Errors and omissions excepted. 2/12/2008
Ripple residue Nominal frequency Pulse ratio Service life Preset Output contact Switching capacity FS319 - Front panel with screw mount Limit switch service life Spark extinguisher Precontact
Permanent precontact as permanent contact (please indicate desired value when ordering) Protection class II Overvoltage category II Pollution degree 2 DIN EN 61000-6-4 DIN EN 61000-6-2 CE conform
Standard DIN EN 61010-1 Emitted interference Interference immunity Approval
FS329 - Front panel with spring clip
1
www.baumerivo.com
Preset counters electromechanic
1 preset, subtracting, permanent precontact Display 5 digits, manual/electric reset
FS309, FS319, FS329
Technical data - mechanical design Display Number of digits Digit height Count mode Step-by-step switching Measuring range Reset Operating temperature Storing temperature Relative humidity Protection DIN EN 60529 E-connection Weight approx. Material FS309 Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth FS319 Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth FS329 Housing type Mounting Dimensions W x H x L Cutout dimensions Installation depth Built-in housing Front panel with spring clips 53.2 x 53.2 x 61 mm 51 x 51 mm 77.5 mm Built-in housing Front panel with 2 screws 60 x 75 x 61 mm 51 x 51 mm 77.5 mm Accessories Front frames for FS309 Z 102.01A Z 102.02A Z 107.02A Front frame with knob lock provided on transparent cover
Subject to modification in technic and design. Errors and omissions excepted. 2/12/2008
Connection diagram
White numbers on black 5-digits 4.5 mm 1 impulse = 1 count 99 999 Manual by reset button 0...+60 C -20...+70 C 80 % non-condensing IP 41 Soldering pins (flat) 150 g Housing: Noryl PPO, black Socket box Socket box 50 x 50 x 85.9 mm 50 x 50 mm 85.9 mm Trigger level Count Power Min. pulse duration Min. pulse interval Switch on time (at 25 C) Electronic reset Power Min. pulse duration Min. pulse interval Switch on time (at 25 C) Voltage DC 2.2 W 25 ms 25 ms 100 % Voltage DC 22 W 250 ms 10 % max. 1 min Voltage AC 2.4 VA 50 ms 50 ms 100 % Voltage AC 25 VA 250 ms 10 % max. 1 min Reset Subtracting in 2 half steps + (-) (+) Voltage Voltage counting 1 2 5 6 21 20 22 18 17 19
End contact
Preliminary contact
9x pulse duration 9x pulse duration
Front frame with cylinder lock provided on transparent cover Front frame, insertion cutout 50 x 50 mm
2
www.baumerivo.com
Preset counters electromechanic
1 preset, subtracting, permanent precontact Display 5 digits, manual/electric reset
FS309, FS319, FS329
Part number Front panel with screw mount FS309. Precontact B Without permanent precontact K With permanent precontact A3 A5 A8 A9 550A 551A Voltage 24 VDC 24 VAC 110 VAC 230 VAC 550A 551A A3 A5 A8 A9 Front panel with screw mount FS319. Precontact B Without permanent precontact K With permanent precontact Voltage 24 VDC 24 VAC 110 VAC 230 VAC
Reset With button reset and electric reset With button reset and electric reset, permanent precontact
Reset With button reset and electric reset With button reset and electric reset, permanent precontact
Front panel with spring clips mount FS329. Precontact B Without permanent precontact K With permanent precontact A3 A5 A8 A9 550A 551A Voltage 24 VDC 24 VAC 110 VAC 230 VAC
Subject to modification in technic and design. Errors and omissions excepted.
Reset With button reset and electric reset With button reset and electric reset, permanent precontact
3
www.baumerivo.com
2/12/2008
Preset counters electromechanic
1 preset, subtracting, permanent precontact Display 5 digits, manual/electric reset
FS309, FS319, FS329
Dimensions FS309 socket box 50 8 6 FS319 front panel with 2 screws 12.5 30 8
50
18.5
67.4
10 5 50 60 16.5 61 3 10
FS329 front panel with spring clip 1.6 8
53.2
50
1.6
50 53.2
6 16.5 61 3 10
75 63
50
4
www.baumerivo.com
2/12/2008
Subject to modification in technic and design. Errors and omissions excepted.


▲Up To Search▲   

 
Price & Availability of FS309551AA5B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X