![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Contact Factory for Replacement Model Input Specifications Parameter Operating Range Current (when supplying 30ADC at 48VDC) Conditions 45 - 65 Hz, single phase, no taps required 105 VAC 208 VAC 240 VAC Min 106 Typ 20 10 8.5 Max 264 Units VAC AAC AAC AAC % Efficiency Power Factor Correction (PFC) input range between 105VAC-264VAC >85 >.99 MEASUREMENTS OF RM4830 Module Weight Height Depth Width Weight Height Depth Width 14 lbs. 5 U (8.75") 15.55" 3.35" 21 lbs. 5 U (8.75") 15.55" 23" rack mount Shelf* * These measurements are specifically for the 180A Power Shelf for up to 6 quantity RM 4830. Please contact factory for other shelf and power plant options. GENERAL FEATURES Hot Swappable Modules These shelf-mounted modules are easy and safe to install or remove while system is operational without affecting the overall system's performance. Parallel Operation and Automatic Load Sharing A series of RM4830 rectifiers will automatically share equal amounts of the load current when operating in parallel within 5% of the average current for the load applied. N+1 Operation The rectifier can operate in true N + 1 redundacy mode. Remote Equalize The rectifier output may be changed from float to equalize via remote signal. Current Limit When rectifier current reaches 30ADC - 32ADC, the unit will automatically limit the current down to short circuit conditions with no fold back. LED Indicators The front panel includes a 10 segment yellow LED output current bar graph, a green normal operation LED, and a red rectifier failed LED. Safety UL/CUL Recognized: UL 1950/CSA 950. File No.: E131694 EMI filtering to FCC and VDE-0875 limits. Page 2 RM4830 6/98 REV A Output Specifications Parameter Voltage Adjustment Range float voltage Regulation Load Current Filtering Voice band Wide band noise equalize voltage 0-100% load within specified input voltage and frequency range within a 10 - 100% rating 40 40 0.5 10 60 60 VDC VDC % % Conditions Min Typ Max Units 20 MHz bandwidth <32 <250 <40 dBrnC mV p-p mVrms ENVIRONMENTAL Temperature Operating Storage Temperature Coefficient Humidity Altitude Heat Dissipation Audible Noise after half hour warm-up non-condensing 0 +32 -50 -58 0.01 0 0 0 980 <65 +50 122 85 185 95 7000 2133 @54V 2 ft. from any vertical surface C F C F V/C % ft. m Btu/hr dBa PROTECTION, ALARM AND CONTROL SYSTEMS Rectifier Failure Alarm (RFA) Problems occurring because of an unacceptable relationship between the output power and load conditions will cause a Rectifier Failure Alarm (RFA). This alarm consists of a red LED. Conditions which may lead to an RFA are: Low Current - Output current has decreased to below 2% of its rated value. Unit Shutdown - Any shutdown occurrence due to overvoltage, external shutdown command, unacceptable ambient temperature conditions or low AC input voltage. Fan Malfunction - The fan has stopped operating or is not providing the airflow needed to cool the unit. Over Temperature - The ambient temperature has exceeded 50C. High Voltage Shutdown (HVSD) The unit's built-in high voltage limit is permanently set at 60.5VDC. When internal shutdown occurs, the unit may be restarted by a local switch or by a remote signal. Surge Protection The unit will withstand lightning and input surges of 6000V/3000A. Under Voltage Protection When input voltage is below 106 VAC (with tolerance), the rectifier's operation is automatically inhibited. Output Circuit Protection Device (Fuse) The unit has one internal output protection fuse which is in series with the -48VDC output. RM4830 6/98 REV A Page 3 Mechanical SIDE 14.30 4.95 + .25 FAN 4.70 + .25 1.25 FRONT 3.35 2.35 + .25 4.35 + .25 4830 8.63 1st TEST BURN-IN HI-POT 2nd TEST QA 30 27 24 21 18 15 12 9 6 3 VOLTAGE PWR/RESET FLT EQL Standard Options are shown, consult factory for other available options. The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user's own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems or in aircraft control applications. Page 4 RM4830 6/98 REV A |
Price & Availability of TPSRM4830
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |