![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
3-Phase Filters FMBD NEO www.schurter.com/pg80 2-stage filter for 3-phase systems with neutral conductor Description -Terminalsforthreephases,neutralconductorandground -Veryhighsymmetricalandasymmetricalattenuationloss -Inthefrequencyrangefrom10kHzupto300MHz Applications Standards Approvals -Voltagerating520VACforworldwideacceptance -Protectionagainstinterferencevoltagefromthemains -Especiallydesignedforindustrialapplicationssuchas:FrequencyConverters,StepperMotorDrives,UPS-Systems,Inverters -IEC60939 -UL1283,Edition5,CSA22.2No.8-M1986,@Ta75C -VDELicenseNumber:pending -ULLicenseNumber:E72928 References Weblinks GeneralProductInformation Approvals,RoHS,CHINA-RoHS,Distributor-Stock-Check Technical Data 8-200A 300/520VAC,50/60Hz 8-200A@50(75)C/300/520VAC; 50/60Hz OverloadCurrent 1.5xIr DielectricStrengthfor520VAC 2.25kVDCbetweenL-L 1.7kVDCbetweenL-N 2.75kVDCbetweenL-PE 2.75kVDCbetweenN-PE Testvoltage2sec NumberofFilterStages 2 Weight 1.1-8.6kg Material:Housing Metal SealingCompound UL94V-0 RatedCurrent Ratedvoltage Approvalfor Mounting Terminal OperatingTemperature[C] ClimaticCategory DegreeofProtection ProtectionClass MTBF Screw-onmountingonchassis ScrewClamp -25Cto100C 25/100/21acc.toIEC60068-1 IP20acc.toIEC60529 Suitableforapplianceswithprotection class1acc.toIEC61140 >200'000hacc.toMIL-HB-217F EMC Products FMBD NEO www.schurter.com/pg80 Dimensions Case 2A 3-Phase Filters max. 155 (120) max. 115 3x11.5=(34.5) max. 80 M6x14; 3-4 Nm 54.5 14 80 0.3 6.50.3 (4x) 4mm 2 ; 0.5-0.6 Nm max. 145 127.5-2 0 1) 2) 1) Line 2) Load Case 2B max. 165 (130) max. 125 3x23=(69) max. 115 M6x14; 3-4 Nm 50 14 90 0.3 6.5 (4x) 10mm 2 ; 1.5-1.8 Nm max. 155 137.5 -2 0 1) 2) 1) Line 2) Load EMC Products 89 35 3-Phase Filters FMBD NEO www.schurter.com/pg80 Case 2C max. 220 (160) max. 125 3x25=(75) max. 125 M10; 10-17 Nm 94 100 0.3 6.5 0.3 (4x) 18 25mm 2 ; 2-2.2 Nm max. 155 137.5 -2 0 1) 2) 1) Line 2) Load Case 2D max. 315 (230) max. 135 3x28=(84) max. 125 83 55 M10; 10-17 Nm 120 0.3 6.5 0.3 (4x) 24 50mm2 ; 2.2-2.5 Nm max. 165 147.5 -2 0 1) 2) 1) Line 2) Load EMC Products 40 3 FMBD NEO www.schurter.com/pg80 Case 2E max. 335 (250) max. 140 3x30=(90) 3-Phase Filters max. 140 M10; 10-17 Nm 98 18 200 0.3 6.5 0.3 (4x) 50mm 2 ; 2.2-2.5 Nm max. 170 152.5 -2 0 1) 2) 1) Line 2) Load Case 2F max. 380 (280) max. 140 3x30=(90) max. 170 24 230 0.3 6.5 0.3 (4x) 95mm 2 ; 15-20 Nm max. 170 152.5 -2 0 1) 2) 1) Line 2) Load EMC Products 45 M10; 10-17 Nm 106.5 55 3-Phase Filters FMBD NEO www.schurter.com/pg80 L [mH] 2 1.3 1.6 1 0.7 0.6 0.6 0.4 0.3 L [H] 4 12 12 12 7.5 9 9 9 9 C [F] 2.2 2.2 4.7 4.7 4.7 8.2 13.6 13.6 13.6 C [F] 2.2 2.2 4.7 4.7 4.7 8.2 13.6 13.6 13.6 C3 [F] 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 R [M] R [M] R3 [M] 1 1 1 1 0.5 0.5 0.5 1 1 1 1 1 1 0.5 0.5 0.5 2 2 2 2 2 2 2 2 2 Technical data to the filter components Rated Current @ Ta 0C (7C) [A] 8 (5) 16 (11) 25 (16) 36 (21) 64 (40) 80 (50) 120 (96) 160 (100) 200 (140) Diagrams L1 L2 1) L3 N PE 1) Line 2) Load C3/R3 C1/R1 C1/R1 C1/R1 L1 C2/R2 C2/R2 C2/R2 L2 L1' L2' L3' 2) N' PE Derating Curves Permissible Working Current as a Function of Ambient Temperature Admissible operating current in % of In 100 80 60 UL Listet 40 20 0 0 20 40 60 75 100 Ambient air temperature Ta C EMC Products FMBD NEO www.schurter.com/pg80 Attenuation Loss 7A IndustrialVersion 3-Phase Filters ........01/100differentialmode....100/0.1differentialmode----differentialmode_____commonmode 16A 25A 36A 64A 80A 120A 160A 200A Variants Rated Current @ Ta 0C (7C) [A] Tripped Power Dissipation [W] Contact Resistance [m] Leakage Current [mA] ) Weight [kg] Screw clamps [mm] ) 4 4 10 10 25 50 50 95 95 Housing Packaging unit [PCS] Order Number 8 (5) 16 (11) 25 (16) 36 (21) 64 (40) 80 (50) 120 (96) 160 (100) 200 (140) 3.2 7 9.5 12.5 21.3 22.6 43.2 37.9 41.6 12.5 6.8 3.8 2.4 1.3 0.88 0.75 0.37 0.26 <1 <1 <1 <1 <1 <1 <1 <1 <1 1.1 1.2 1.8 2 2.8 5.7 6.3 8 8.6 2A 2A 2B 2B 2C 2D 2E 2F 2F 2 2 2 2 1 1 1 1 1 FMBD-B92A-0812 FMBD-B92A-1612 FMBD-B92A-2512 FMBD-B92B-3612 FMBD-B92C-6412 FMBD-B92D-8012 FMBD-B92E-J212 FMBD-B92F-J612 FMBD-B92F-K012 1)Maximumleakagecurrentundernormaloperatingconditions,assumingthatallthreephasesandtheneutralconductorareconnectedtothesupplyandtheconsumer. Underthiscondition,thecurrentwillmainlyreturnthroughtheneutralline,notasearthleakage. 2)Maximumconductorcrosssection(wiregauge)tobeused;acomparativetableforAWGandmmvaluescanbefoundinthegeneralproductinformationwww.schurter. com/emc_info Thespecifications,descriptionsandillustrationsindicatedinthisdocumentarebasedon EMC Products currentinformation.Allcontentissubjecttomodificationsandamendments. |
Price & Availability of FMBD
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |