![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
75W Single Output Medical Type Features : Universal AC input/Full range Low leakage current<200uA RPS-75 series Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load UL60601-1/IEC60601-1/EN60601-1 medical safety approved No load power consumption<0.75W Fixed switching frequency at 65KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD (23.5CFM) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RPS-75-3.3 3.3V 15A 0 ~ 20A 49.5W 66W 2.9 ~ 3.6V 2.0% 0.5% 1.5% 80ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 73% 1.5A/115VAC 78% 1A/230VAC 50A/230VAC 82% 83% 85% 86% 86% RPS-75-5 5V 14A 0 ~ 18.7A 70W 94W 80mVp-p 4.75 ~ 5.5V 2.0% 0.5% 1.5% RPS-75-12 12V 6.3A 0 ~ 8.3A 75.6W 99.6W 120mVp-p 11.4 ~ 13.2V 1.0% 0.5% 1.0% RPS-75-15 15V 5A 0 ~ 6.7A 75W 100.5W 150mVp-p 13.5 ~ 16.5V 1.0% 0.5% 1.0% RPS-75-24 24V 3.2A 0 ~ 4.2A 76.8W 100.8W 240mVp-p 22.8 ~ 27.6V 1.0% 0.5% 1.0% RPS-75-36 36V 2.1A 0 ~ 2.8A 75.6W 100.8W 300mVp-p 34.2 ~ 39.6V 1.0% 0.5% 1.0% RPS-75-48 48V 1.6A 0 ~ 2.1A 76.8W 100.8W 300mVp-p 45.6 ~ 52.8V 1.0% 0.5% 1.0% RIPPLE & NOISE (max.) Note.2 80mVp-p 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load 20ms/115VAC at full load 127 ~370VDC COLD START 25A/115VAC Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. 3.8 ~ 4.46V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V 55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60601-1, TUV EN60601-1, IEC60601-1 approved SAFETY & EMC (Note 4) I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 446.8K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.23Kg; 63pcs/15.5Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:RPS-75-SPEC 2008-03-25 75W Single Output Medical Type Mechanical Specification FAN RPS-75 series Unit:mm 23.5CFM min. 5.7 15cm CN2 CN1 1 2 3 4 5 6 7 8 1 CN3 2 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 64.75 76.2 3 2 1 DC Output Connector (CN2) : JST B8P-VH or equivalent 45.6 115.8 127 3.8 Pin No. 1,2,3,4 5,6,7,8 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Remote Sense(CN3) : JST B2B-XH or equivalent Pin No. 1 2 Assignment RS+ RSMating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent Block Diagram RECTIFIERS & FILTER RECTIFIERS & FILTER 3max. 31 fosc : 65KHz +S I/P EMI FILTER POWER SWITCHING +V -V -S FG O.L.P. CONTROL DETECTION CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 133 100 23.5CFM Forced air Cooling Others 100 90 80 70 Convection Cooling 3.3V,5V 80 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 70 (HORIZONTAL) 50 60 50 40 20 -20 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RPS-75-SPEC 2008-03-25 |
Price & Availability of RPS-75-24
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |