If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
60W Single Output LED Power Supply 1/2 Features : CEN-60 series Universal AC input / Full range (up to 295VAC) Protections: Short circuit / Overload / Over voltage / Over temperature Output voltage and constant current level adjustable Built-in active PFC function IP66 design for indoor or outdoor installations Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty F 110 M M SELV SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CEN-60-12 12V 5A 0 ~ 5A 60W CONSTANT CURRENT OPERATION VOLTAGE Note.5 9 ~ 12V CEN-60-15 15V 11.25 ~ 15V 4A 0 ~ 4A 60W 2.4Vp-p 3 ~ 4A CEN-60-20 20V 15 ~ 20V 3A 0 ~ 3A 60W 1.8Vp-p 17 ~ 22V 2.3 ~ 3A CEN-60-24 24V 18 ~ 24V 2.5A 0 ~ 2.5A 60W 2.4Vp-p 22 ~ 27V 1.9 ~ 2.5A 30V IP66 CEN-60-36 36V 27 ~ 36V 1.7A 0 ~ 1.7A 61.2W 3.6Vp-p 33 ~ 40V 1.3 ~ 1.7A CEN-60-42 42V 31.5 ~ 42V 1.45A 0 ~ 1.45A 60.9W 4Vp-p 37 ~ 46V 1.1 ~ 1.45A CEN-60-48 48V 36 ~ 48V 1.3A 0 ~ 1.3A 62.4W 4.6Vp-p 43 ~ 53V 1 ~ 1.3A CEN-60-54 54V 40.5 ~ 54V 1.15A 0 ~ 1.15A 62.1W 5Vp-p 49 ~ 58V 0.9 ~ 1.15A CEN-60-30 22.5 ~ 30V 2A 0 ~ 2A 60W 3Vp-p 27 ~ 33V 1.5 ~ 2A RIPPLE & NOISE (max.) Note.2 2Vp-p CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 10% 3.0% 5.0% VOLTAGE ADJ. RANGE (SVR1) 10.8 ~ 13.5V 13.5 ~ 17V 1400ms / 230VAC 2800ms / 115VAC at full load Note.4 90 ~ 295VAC 127 ~ 417VDC PF>0.95 / 230VAC at full load 90% 90% 91% 91% 47 ~ 63Hz PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC 86% 0.8A/115VAC 45A/230VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 14.5 ~ 17V 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V Protection type : Shut down o/p voltage, re-power on to recover 85 10 (RTH1) (Refer to output load derating curve) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 20 ~ 95% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, TUV EN61347-1, EN61347-2-13, IP66 approved 41 ~ 46V 47 ~ 52V 54 ~ 60V 59 ~ 65V 87% 88% 89% 90% 0.4A/230VAC <0.75mA / 240VAC I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE SAFETY & EMI CONDUCTION & RADIATION Compliance to EN55015 EMC Compliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS NOTE Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level (surge 4KV), criteria A 523.4Khrs min. MIL-HDBK-217F (25 183*62.5*40.5mm (L*W*H) 0.56Kg;24pcs/14.4Kg/1.11CUFT ) DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Direct connecting to LEDs is not suggested for models with RIPPLE & NOISE > 10% and using additional drivers is highly recommended. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. File Name:CEN-60-SPEC 2010-09-01 60W Single Output LED Power Supply Mechanical Specification CEN-60 Case No.993B series Unit:mm 183 10.5 7.6 162 300 20 300 20 30.6 45 62.5 Vo Io ADJ. ADJ. AC/L(Brown) AC/N(Blue) FG (Green/Yellow) 18AWG 3C SJTW 4.6 4PL 18AWG 2C SVT +V(Red) -V(Black) Block Diagram RECTIFIERS & FILTER DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. fosc : 50KHz(115VAC) 75KHz(230VAC) POWER SWITCHING +V -V I/P EMI FILTER & RECTIFIERS FG O.L.P. O.C.P. Derating Curve Static Characteristics Ta:25 100 100 90 80 80 70 60 LOAD (%) 40 LOAD (%) 60 50 40 20 -30 -25 -5 0 15 30 50 60 70 (HORIZONTAL) 90 100 125 135 145 155 165 175 180 200 230 295 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:CEN-60-SPEC 2010-09-01 40.5 60W Single Output LED Power Supply Power Factor Characteristic Power factor will be higher than 0.9 when output loading is 75% or higher. CEN-60 series Constant Current Mode 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 0.84 0.82 0.8 0.78 50% 60% 70% LOAD PF 230VAC 110VAC 80% 90% 100% EFFICIENCY vs LOAD (48V Model) CEN-60 series possess superior working efficiency that up to 91% can be reached in field applications. 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD EFFICIENCY (%) 230VAC 110VAC DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)]. 100 (B) Constant Current area (A) Constant Voltage area 50 (max.) (C) Hiccup Protection 50 100 Io (%) Vo(%) Typical LED power supply I-V curve File Name:CEN-60-SPEC 2010-09-01 |
Price & Availability of CEN-60-48
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |