Part Number Hot Search : 
D74ALV 1041J M62720GP NE559 R100F MAX696 157X00 CEFB105
Product Description
Full Text Search
 

To Download CLG-60-48 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 60W Single Output Switching Power Supply
Features :
CLG-60
series
Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications 3 years warranty
F
110
M
M
SELV
EQUIVALENT
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CLG-60-12 12V 5A 0 ~ 5A 60W 11 ~ 13V CONSTANT CURRENT REGION Note.6 8.4 ~ 12V 15V
LPS
CLG-60-20 20V 14 ~ 20V 3A 0 ~ 3A 60W 1.8Vp-p 18 ~ 22V
( for 48V only)
( except for 48V )
IP67
CLG-60-36 36V 25.2 ~ 36V 1.7A 0 ~ 1.7A 61W 3.6Vp-p 32.5 ~ 39V CLG-60-48 48V 33.6 ~ 48V 1.3A 0 ~ 1.3A 62.5W 4.6Vp-p 43.6 ~ 51.8V
CLG-60-15 10.5 ~ 15V 4A 0 ~ 4A 60W 2.4Vp-p 13.8 ~ 16.2V
CLG-60-24 24V 16.8 ~ 24V 2.5A 0 ~ 2.5A 60W 2.7Vp-p 22 ~ 26V
CLG-60-27 27V 18.9 ~ 27V 2.3A 0 ~ 2.3A 62.1W 2.7Vp-p 25 ~ 30V
RIPPLE & NOISE (max.) Note.2 2Vp-p VOLTAGE ADJ. RANGE CURRENT ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE
Fixed can be modified between the range above Fixed can be modified between 3% ~ 25% rated output current 10% 4.0% 10% 1500ms, 100ms / 230VAC 3000ms, 100ms / 115VAC at full load
Note.5 90 ~ 264VAC
127 ~ 370VDC PF>0.98/115VAC at full load 84.5% 0.4A/230VAC 86.5% 86.5% 87% 87% 88%
47 ~ 63Hz PF>0.9/230VAC 83% 0.8A/115VAC 40A/230VAC 0.5mA / 240VAC 95 ~ 110% 130% (max) Protection type : Constant current limiting, recovers automatically after fault condition is removed Note.4 Hiccup mode, recovers automatically after fault condition is removed. 13.8 ~ 16V 17.5 ~ 21V 22.8 ~ 25V 28 ~ 32V Protection type : Shut down o/p voltage, re-power on to recover 12V: 90 10 (TSW1) detect on heatsink of power transistor 10 (TSW1) detect on heatsink of power transistor 15V ~ 48V: 85 -30 ~ +70 -40 ~ +80 0.03%/ 31 ~ 35V 41 ~ 46V 54 ~ 60V
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) 20 ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310 Class 2, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), IP67 approved
WITHSTAND VOLTAGE I/P-O/P:4.25KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61547, light industry level, criteria A 495.7Khrs min. MIL-HDBK-217F (25 172*61.5*39mm (L*W*H) 0.86Kg; 16pcs/14.8Kg/0.54CUFT )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
File Name:CLG-60-SPEC 2008-08-18
60W Single Output Switching Power Supply
Mechanical Specification
CLG-60
Case No. 957A
series
Unit:mm
195.8 12 9.6 300 20
7.08
172
7.28
300 20
32 61.36
AC/L(Brown) AC/N(Blue) FG (Green/Yellow)
18AWG 3C
18AWG 2C 4.2 4PL
+V(Red) -V(Black)
7.28
7.08
32
Block Diagram
RECTIFIERS & FILTER DETECTION CIRCUIT PWM & PFC CONTROL O.V.P.
fosc : 90KHz(115VAC) 120KHz(230VAC)
POWER SWITCHING +V -V
I/P
EMI FILTER & RECTIFIERS
FG
O.L.P.
O.C.P.
Derating Curve
Static Characteristics
Ta:25
100
100 90
80
80 70
60
LOAD (%)
40
LOAD (%)
60 50 40
20
-30
-25
-5
0
15
30
50
60
70
(HORIZONTAL)
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:CLG-60-SPEC 2008-08-18
38.75


▲Up To Search▲   

 
Price & Availability of CLG-60-48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X