![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
MKV AC Capacitors Jump to preceding page B 25 834 Damping, Commutating High dielectric strength High peak-current capability For damping and commutating in the medium frequency range Also for general AC applications Construction q q q q q q q Self-healing Plastic dielectric Oil-impregnated tubular windings (no PCB) Metal-sprayed end faces ensure reliable contacting Cylindrical aluminum case Plastic or ceramic lead-throughs Mounting bolts M8 or M12 Terminals q Screw terminals M10 q Tab connectors 6,3 mm q Dual tab connectors 6,3 mm and 9,5 mm Mounting parts q If the vibration stress is 5 g and the capacitors are 60 mm in diameter and 160 mm in height, the bolt is used for mounting. q In case of a vibration stress > 5 g as well as for larger-sized capacitors mounting details are given in chapter "Mounting parts". Grounding q Mounting bolts for grounding in accordance with VDE 0100 q Grounding identification in accordance with DIN 40 011 Overpressure disconnector (mechanical) When the overpressure disconnector responds, the capacitor extends by up to 8 mm. So leave sufficient space above the terminals when mounting the capacitor. Individual data sheets Individual capacitors of this series are specified in detail (incl. thermal data) on pages 138 ... 167. Upon request, these data sheets are available for each capacitor type. 128 Siemens Matsushita Components B 25 834 Damping, Commutating Technical data Standards IEC 1071-1/2 EN 61071-1/2 VDE 0560 part 120 and 121 2 * 10 -4 Dielectric dissipation factor Max. repetitive rate of voltage rise Max. non-repetitive rate of voltage rise Climatic data: Min. operating temperature Max. operating temperature Average relative humidity Failure quota Load duration Storage temperature limit IEC climatic category (IEC 68-1 and 2) Test A, cold Test B, dry heat Test Ca, damp heat, steady state Values after test Ca: Capacitance change tan 0 (du/dt)max (du/dt)s min max i --C IS --C - 25 C + 85 C 95 % (screw terminals/dual tab 9,5 mm) 75 % (dual tab 6,3 mm/tab 6,3 mm) 300 failures per 109 component hours 100 000 h - 55/+ 85 C 25/085/56 - 25 C + 85 C 56 days/40 C/93 % rel. humidity FQ(co) tLD(co) stg C /C 1% CN Insulation resistance Self-discharge time constant = Dissipation factor change Test data: AC test voltage between terminals between terminals and case R is R is * C tan Screw terminals, dual tab 9,5 mm 1 F 10 000 M > 1 F 10 000 s 1 * 10 -4 Dual tab 6,3 mm 3000 M 3000 s 3 * 10 -4 Tab 6,3 mm 1000 M 1000 s 3 * 10 -4 UTT UTC 1,25 * UN, 50 Hz, 10 s (or DC 1,75 * UN, 10 s) 2 * U i + 1000 V, 50 Hz, 10 s CN Insulation resistance Self-discharge time constant = Dissipation factor (50 Hz) R is R is * C tan Screw terminals, dual tab 9,5 mm 1 F 10 000 M > 1 F 10 000 s 3 * 10 -4 Dual tab 6,3 mm, tab 6,3 mm 3000 M 3000 s Siemens Matsushita Components 129 B 25 834 Damping, Commutating Available ratings UN (V) AC 500 CR (F) 0,10 0,15 0,22 0,33 0,47 0,68 1,0 1,5 2,2 3,3 4,7 6,8 10 15 22 33 47 68 100 150 220 600 750 900 1100 1400 1700 2100 Data book range Upon request 130 Siemens Matsushita Components B 25 834 Damping, Commutating Characteristics and ordering codes CN1) F Imax A i A Is A RS Lself Dimensions Fig. Appr. Ordering code 20 C dxl weight m nH mm g Pg. UN = AC 500 V 33 47 68 100 220 18 80 80 80 80 1300 1900 2700 4000 8800 Ui = AC 450 V 3300 4700 6800 10000 22000 4,9 1,9 1,5 1,4 1,2 90 110 110 180 180 u = 630 V us = 860 V 60 x 86 79,2 x 104 99,3 x 104 79,2 x 248 99,3 x 248 3 2 2 2 2 290 610 970 1500 2300 UTT = AC 620 V, 10 s UTC = AC 2000 V, 10 s B25834-L3336-K009 138 B25834-D3476-K004 B25834-D3686-K004 B25834-D3107-K004 B25834-D3227-K004 UN = AC 600 V 0,68 1,0 1,5 2,2 3,3 4,7 6,8 10 15 22 33 33 47 47 68 100 150 10 10 16 16 16 16 16 18 18 60 80 64 80 64 80 80 80 110 160 240 350 530 190 270 400 600 880 1300 1300 1900 1900 2700 4000 6000 Ui = AC 530 V 270 400 600 880 1300 470 680 1000 1500 2200 3300 3300 4700 4700 6800 10000 15000 25,0 18,0 14,0 10,0 8,7 16,0 13,0 8,0 6,5 3,1 2,4 2,4 2,0 2,0 1,7 1,5 1,3 50 50 50 50 50 90 90 90 90 110 110 110 110 110 180 180 180 u = 750 V us = 1000 V 25 x 48 25 x 48 30 x 48 30 x 48 35 x 48 30 x 80 35 x 80 40 x 86 50 x 86 64,2 x 104 79,2 x 104 79,2 x 104 89,3 x 104 89,3 x 104 64,2 x 248 79,2 x 248 89,3 x 248 5 5 6 6 7 6 7 3 3 2 2 4 2 4 2 2 2 30 30 50 50 60 70 100 130 200 400 610 610 780 780 960 1500 1900 UTT = AC 750 V, 10 s UTC = AC 2100 V, 10 s B25834-F4684-M001 B25834-F4105-K001 B25834-F4155-K001 B25834-F4225-K001 B25834-F4335-K001 140 B25834-F4475-K001 B25834-F4685-K001 B25834-L4106-K009 142 B25834-L4156-K009 B25834-D4226-K004 B25834-D4336-K004 B25834-D4336-K009 B25834-D4476-K004 B25834-D4476-K009 B25834-D4686-K004 B25834-D4107-K004 144 B25834-D4157-K004 1) Capacitance tolerances: For CN < 1,0 F 20 %, for CN 1,0 F 10 % Siemens Matsushita Components 131 B 25 834 Damping, Commutating Characteristics and ordering codes CN1) F Imax A i A Is A RS Lself Dimensions Fig. Appr. Ordering code 20 C dxl weight m nH mm g Pg. UN = AC 750 V 4,7 6,8 10 15 22 22 33 33 47 68 100 16 18 18 18 80 64 80 64 80 80 80 240 340 500 750 1100 1100 1700 1700 2400 3400 5000 Ui = AC 670 V 590 13,0 850 8,4 1250 7,0 1900 5,9 2800 2,6 2800 2,5 4100 2,0 4100 1,9 5900 1,7 8500 1,6 12500 1,4 90 90 90 90 110 110 110 110 180 180 180 u = 940 V us = 1300 V 35,0 x 80 40,0 x 86 50,0 x 86 60,0 x 86 79,2 x 104 79,2 x 104 89,3 x 104 89,3 x 104 64,2 x 248 79,2 x 248 89,3 x 248 7 3 3 3 2 4 2 4 2 2 2 100 130 200 290 610 610 780 780 960 1500 1900 UTT = AC 930 V, 10 s UTC = AC 2400 V, 10 s B25834-F5475-K001 146 B25834-L5686-K009 B25834-L5106-K009 148 B25834-L5156-K009 B25834-D5226-K004 B25834-D5226-K009 B25834-D5336-K004 B25834-D5336-K009 B25834-D5476-K004 B25834-D5686-K004 B25834-D5107-K004 150 UN = AC 900 V 0,10 0,15 0,22 0,33 0,47 0,68 1,0 1,5 2,2 3,3 4,7 6,8 10 15 15 22 22 33 47 68 10 10 10 10 10 10 16 16 16 16 18 18 18 60 60 80 64 80 80 80 50 70 100 90 130 180 300 450 150 230 330 480 700 1100 1100 1500 1500 2300 3300 4800 Ui = AC 780 V 120 180 260 220 320 460 750 1100 390 580 820 1200 1750 2600 2600 3900 3900 5800 8200 12000 33,0 24,0 17,0 29,0 21,0 16,0 12,0 9,8 18,0 14,0 9,0 7,3 6,1 2,8 2,7 2,2 2,1 1,8 1,6 1,4 50 50 50 50 50 50 50 50 90 90 90 90 90 100 100 110 110 180 180 180 u = 1100 V us = 1500 V 25,0 x 48 25,0 x 48 25,0 x 48 25,0 x 48 25,0 x 48 25,0 x 48 30,0 x 48 35,0 x 48 30,0 x 80 35,0 x 80 40,0 x 86 50,0 x 86 60,0 x 86 79,2 x 104 79,2 x 104 89,3 x 104 89,3 x 104 64,2 x 248 79,2 x 248 89,3 x 248 5 5 5 5 5 5 6 7 6 7 3 3 3 2 4 2 4 2 2 2 30 30 30 30 30 30 50 60 70 100 130 200 290 610 610 780 780 960 1500 1900 UTT = AC 1150 V, 10 s UTC = AC 2600 V, 10 s B25834-F6104-M001 B25834-F6154-M001 B25834-F6224-M001 B25834-F6334-M001 B25834-F6474-M001 B25834-F6684-M001 B25834-F6105-K001 B25834-F6155-K001 B25834-F6225-K001 B25834-F6335-K001 B25834-L6475-K009 B25834-L6685-K009 B25834-L6106-K009 B25834-D6156-K004 B25834-D6156-K009 B25834-D6226-K004 B25834-D6226-K009 B25834-D6336-K004 B25834-D6476-K004 B25834-D6686-K004 152 154 156 158 1) Capacitance tolerances: For CN < 1,0 F 20 %, for CN 1,0 F 10 % 132 Siemens Matsushita Components B 25 834 Damping, Commutating Characteristics and ordering codes CN1) F Imax A i A Is A RS Lself Dimensions Fig. Appr. Ordering code 20 C dxl weight m nH mm g Pg. UN = AC 1100 V 4,7 6,8 10 15 22 33 18 18 60 80 80 80 380 540 800 1200 1800 2600 Ui = AC 990 V 940 1400 2000 3000 4400 6600 17,0 13,0 6,3 4,9 3,7 2,8 140 140 150 150 150 150 u = 1400 V us = 1900 V 40,0 x 156 50,0 x 156 64,2 x 176 79,2 x 176 89,3 x 176 99,3 x 176 3 3 1 1 1 1 240 370 680 1000 1300 1600 UTT = AC 1400 V, 10 s UTC = AC 3000 V, 10 s B25834-L7475-K009 B25834-L7685-K009 B25834-D7106-K004 B25834-D7156-K004 B25834-D7226-K004 B25834-D7336-K004 160 UN = AC 1400 V 4,7 6,8 10 15 22 60 60 80 80 80 470 680 1000 1500 2200 Ui = AC 1300 V 1200 1700 2500 3800 5500 9,3 6,6 5,2 3,8 2,9 150 150 150 150 150 u = 1800 V us = 2400 V 64,2 x 176 64,2 x 176 79,2 x 176 89,3 x 176 99,3 x 176 1 1 1 1 1 680 680 1000 1300 1600 UTT = AC 1800 V, 10 s UTC = AC 3600 V, 10 s B25834-D0475-K004 B25834-D0685-K004 B25834-D0106-K004 162 B25834-D0156-K004 B25834-D0226-K004 UN = AC 1700 V 4,7 6,8 10 15 22 60 60 80 80 80 560 820 1200 1800 2600 Ui = AC 1500 V 1400 2000 3000 4500 6600 13,0 9,0 7,0 5,3 3,9 220 220 220 220 220 u = 2100 V us = 2900 V 64,2 x 248 64,2 x 248 79,2 x 248 89,3 x 248 99,3 x 248 1 1 1 1 1 960 960 1500 1900 2300 UTT = AC 2100 V, 10 s UTC = AC 4000 V, 10 s B25834-D1475-K004 B25834-D1685-K004 B25834-D1106-K004 B25834-D1156-K004 B25834-D1226-K004 164 UN = AC 2100 V 3,3 4,7 6,8 10 15 60 60 80 80 80 530 750 1100 1600 2400 Ui = AC 1900 V 1300 1900 2700 4000 6000 13,0 9,4 7,4 5,4 4,1 220 220 220 220 220 u = 2600 V us = 3600 V 64,2 x 248 64,2 x 248 79,2 x 248 89,3 x 248 99,3 x 248 1 1 1 1 1 960 960 1500 1900 2300 UTT = AC 2600 V, 10 s UTC = AC 4800 V, 10 s B25834-D2335-K004 B25834-D2475-K004 B25834-D2685-K004 B25834-D2106-K004 166 B25834-D2156-K004 1) Capacitance tolerance 10 % Siemens Matsushita Components 133 B 25 834 Damping, Commutating Dimensional drawing 1 Screw terminals M10 M10 Dimensional drawing 2 Screw terminals M10 M10 24,5 _ 2 24,5 _ 2 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 57 _ 3 47 _ 3 20 min. ~4 l l l1 l1 10 min. ~4 od 1 od 1 16+1 16+1 M12 M12 d d 13 min. 35 KLK1413-6 13 min. 35 KLK1412-X Dimensions in mm Dimensions in mm Creepage Cleardistance ance d -1,2 l -4 d1 -0,4 l1min 135 204 135 204 135 204 135 204 d -1,2 l -4 d1 -0,4 l1min 135 204 75 204 75 204 75 204 Creepage Cleardistance ance 64,2 176 60,2 64,2 248 60,2 79,2 176 75,2 79,2 248 75,2 89,3 176 85,2 89,3 248 85,2 99,3 176 95,2 99,3 248 95,2 Max. torque terminals*) 20 13 7 Nm 64,2 104 60,2 64,2 248 60,2 79,2 104 75,2 79,2 248 75,2 89,3 104 85,2 89,3 248 85,2 99,3 104 95,2 99,3 248 95,2 Max. torque terminals*) 10 10 7 Nm *) The terminal torque must not act upon the ceramic. So the lead should be locked between two nuts. Mounting parts (included in delivery) Threaded bolt M12 Max. torque 10 Nm Toothed washer J 12,5 DIN 6797 Hex nut M12 ISO 4035 134 Siemens Matsushita Components B 25 834 Damping, Commutating Dimensional drawing 3 Dual tab connectors 6,3 mm 6,30,1 8+0,5 17,5 max. Dimensional drawing 4 Dual tab connectors 9,5 mm 15,5 min. Tab connector A 9,5 x 1,2 DIN 46 244 l 75 min. l od 1 16+1 l1 M12 24 6,8+0,2 d 0,80,04 KLK1297-E d 352 33 _ 3 ~4 ~ KLK1294-P Dimensions in mm Dimensions in mm Clearance d +0,5 -0,2 40 40 50 50 60 l +1 -2 86 156 86 156 86 l1+1*) Creepage distance 8 8 12 10 12 12 d -1,2 79,2 89,3 l -4 104 104 d1-0,4 Creepage distance 75,2 10 85,2 Clearance 10 6 *) 8 mm = threaded bolt M8 12 mm = threaded bolt M12 Mounting parts (included in delivery) Threaded bolt M8 M12 Max. torque 4 Nm 10 Nm Toothed washer J 8,2 DIN 6797 J 12,5 DIN 6797 Hex nut M 8 ISO 4035 M12 ISO 4035 Siemens Matsushita Components 135 B 25 834 Damping, Commutating Dimensional drawing 5 Tab connectors 6,3 mm 18 max. Dimensional drawing 6 Tab connectors 6,3 mm 18 max. Tab connector A 6,3 x 0,8 DIN 46 244 Tab connector A 6,3 x 0,8 DIN 46 244 l 8+1 8+1 l M8 M8 15,50,5 KLK1415-M 15,50,5 KLK1416-V 2 d 1 d Dimensions in mm Dimensions in mm Creepage distance 9 Clearance 7 d +0,5 -0,2 l2 48 d +0,5 -0,2 30 30 1 2 l2 48 80 Creepage distance 9 Clearance 7 25 Mounting parts (included in delivery) Threaded bolt M8 Max. torque 4 Nm Toothed washer J 8,2 DIN 6797 Hex nut M 8 ISO 4035 136 Siemens Matsushita Components B 25 834 Damping, Commutating Dimensional drawing 7 Tab connectors 6,3 mm 13 max. Tab connector A 6,3 x 0,8 DIN 46 244 8+1 l M8 Dimensions in mm d +0,5 -0,2 35 35 l2 48 80 Creepage distance 6 15,50,5 KLK1418-C d 1 2 Clearance 6 Mounting parts (included in delivery) Threaded bolt M8 Max. torque 4 Nm Toothed washer J 8,2 DIN 6797 Hex nut M 8 ISO 4035 Siemens Matsushita Components 137 B 25 834 Damping, Commutating 33 F / 500 Vac Ordering code: B25834-L3336-K009 Characteristics 33 F 10 % AC 500 V AC 450 V 18 A 90 nH 2 * 10 -4 4,9 m 17,5 max. 6,30,1 8+0,5 CN, tol. UN Ui Imax Lself tan 0 RS Maximum ratings _ 0,2 60 +0,5 Test data 24 UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 620 V, 10 s AC 2000 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque Terminals 0,80,04 6,8+0,2 KLK1317-X u us i Is (du/dt)max (du/dt)s 630 V 860 V 1,3 kA 3,3 kA 40 V/s 100 V/s 12+1 _2 86 +1 M12 - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C 60 mm x 86 mm 290 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 3000 s Dual tab connector 6,3 mm Terminal cross section 1,5 mm2 Creepage distance Clearance 10 mm 6 mm Overpressure disconnector 138 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-L3336-K009 Dielectric power dissipation PD versus repetition frequency f0 uac = 500 V uac = 450 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 6,1 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 139 B 25 834 Damping, Commutating 13 max. 3,3 F / 600 Vac Ordering code: B25834-F4335-K001 Characteristics 3,3 F 10 % AC 600 V AC 530 V 16 A 50 nH 2 * 10 -4 8,7 m Tab connector A 6,3 x 0,8 DIN 46 244 CN, tol. UN Ui Imax Lself tan 0 RS 8+1 482 M8 Maximum ratings u us i Is (du/dt)max (du/dt)s Test data 750 V 1000 V 530 A 1300 A 160 V/s 400 V/s 15,50,5 KLK1431-4 _ 0,2 35 +0,5 UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 750 V, 10 s AC 2100 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 35 mm x 48 mm 60 g Oil Threaded bolt M8 9,5 mm 4 Nm - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 1000 s Terminals Tab connector 6,3 mm Terminal cross section 1 mm2 Creepage distance Clearance 6 mm 6 mm Overpressure disconnector 140 Siemens Matsushita Components 1 2 B 25 834 Damping, Commutating Thermal data B25834-F4335-K001 Dielectric power dissipation PD versus repetition frequency f0 uac = 600 V uac = 540 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 10,8 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 141 B 25 834 Damping, Commutating 10 F / 600 Vac Ordering code: B25834-L4106-K009 Characteristics 10 F 10 % AC 600 V AC 530 V 18 A 90 nH 2 * 10 -4 8 m 17,5 max. 6,30,1 8+0,5 CN, tol. UN Ui Imax Lself tan 0 RS Maximum ratings _ 0,2 40 +0,5 u us i Is (du/dt)max (du/dt)s Test data 24 750 V 1000 V 400 A 1000 A 40 V/s 100 V/s 8+1 _2 86 +1 M8 6,8+0,2 0,80,04 KLK1432-C UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 750 V, 10 s AC 2100 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque Terminals - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C 40 mm x 86 mm 130 g Oil Threaded bolt M8 9,5 mm 4 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 3000 s Dual tab connector 6,3 mm Terminal cross section 1,5 mm2 Creepage distance Clearance 10 mm 6 mm Overpressure disconnector 142 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-L4106-K009 Dielectric power dissipation PD versus repetition frequency f0 uac = 600 V uac = 540 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 9,8 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 143 B 25 834 Damping, Commutating 100 F / 600 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D4107-K004 Characteristics 100 F 10 % AC 600 V AC 530 V 80 A 180 nH 2 * 10 -4 1,5 m 47 _ 3 248 _ 4 204 min. CN, tol. UN Ui Imax Lself tan 0 RS 10 min. ~4 o75,2 _ 0,4 Maximum ratings Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 750 V, 10 s AC 2100 V, 10 s 10000 s 3 * 10 -4 79,2 _ 1,2 u us i Is (du/dt)max (du/dt)s 750 V 1000 V 4 kA 10 kA 40 V/s 100 V/s 16+1 M12 13 min. 35 KLK1411-P - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 79,2 mm x 248 mm 1500 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 10 mm 10 mm Overpressure disconnector 144 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D4107-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 600 V uac = 540 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 1,9 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 145 B 25 834 Damping, Commutating 13 max. 4,7 F / 750 Vac Ordering code: B25834-F5475-K001 Characteristics 4,7 F 10 % AC 750 V AC 670 V 16 A 90 nH 2 * 10 -4 13 m Tab connector A 6,3 x 0,8 DIN 46 244 8+1 CN, tol. UN Ui Imax Lself tan 0 RS 802 M8 Maximum ratings u us i Is (du/dt)max (du/dt)s Test data 940 V 1300 V 240 A 590 A 50 V/s 125 V/s 15,50,5 KLK1426-3 _ 0,2 35 +0,5 UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 930 V, 10 s AC 2400 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 35 mm x 80 mm 100 g Oil Threaded bolt M8 9,5 mm 4 Nm - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 1000 s Terminals Tab connector 6,3 mm Terminal cross section 1 mm2 Creepage distance Clearance 6 mm 6 mm Overpressure disconnector 146 Siemens Matsushita Components 1 2 B 25 834 Damping, Commutating Thermal data B25834-F5475-K001 Dielectric power dissipation PD versus repetition frequency f0 uac = 750 V uac = 675 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 16,6 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 147 B 25 834 Damping, Commutating 10 F / 750 Vac Ordering code: B25834-L5106-K009 Characteristics 10 F 10 % AC 750 V AC 670 V 18 A 90 nH 2 * 10 -4 7 m 17,5 max. 6,30,1 8+0,5 CN, tol. UN Ui Imax Lself tan 0 RS Maximum ratings _ 0,2 50 +0,5 UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 930 V, 10 s AC 2400 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque Terminals 0,80,04 Test data 24 6,8+0,2 KLK1433-K u us i Is (du/dt)max (du/dt)s 940 V 1300 V 500 A 1250 A 50 V/s 125 V/s 12+1 _2 86 +1 M12 - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C 50 mm x 86 mm 200 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 3000 s Dual tab connector 6,3 mm Terminal cross section 1,5 mm2 Creepage distance Clearance 10 mm 6 mm Overpressure disconnector 148 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-L5106-K009 Dielectric power dissipation PD versus repetition frequency f0 uac = 750 V uac = 675 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 8,6 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 149 B 25 834 Damping, Commutating 100 F / 750 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D5107-K004 Characteristics 100 F 10 % AC 750 V AC 670 V 80 A 180 nH 2 * 10 -4 1,4 m 47 _ 3 248 _ 4 204 min. 10 min. ~4 CN, tol. UN Ui Imax Lself tan 0 RS o85,2 _ 0,4 Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 930 V, 10 s AC 2400 V, 10 s 10000 s 3 * 10 -4 89,3 _ 1,2 u us i Is (du/dt)max (du/dt)s 940 V 1300 V 5 kA 12,5 kA 50 V/s 125 V/s 16+1 Maximum ratings M12 13 min. 35 KLK1434-T - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 89,3 mm x 248 mm 1900 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 10 mm 10 mm Overpressure disconnector 150 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D5107-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 750 V uac = 675 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 1,7 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 151 B 25 834 Damping, Commutating 0,1 F / 900 Vac Ordering code: B25834-F6104-M001 Characteristics 0,1 F 20 % AC 900 V AC 780 V 10 A 50 nH 2 * 10 -4 33 m 18 max. Tab connector A 6,3 x 0,8 DIN 46 244 CN, tol. UN Ui Imax Lself tan 0 RS Maximum ratings 8+1 482 M8 u us i Is (du/dt)max (du/dt)s Test data 1100 V 1500 V 50 A 120 A 480 V/s 1200 V/s 15,50,5 KLK1417-4 _ 0,2 25 +0,5 UTT UTC Ris tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1150 V, 10 s AC 2600 V, 10 s 3000 M 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 25 mm x 48 mm 30 g Oil Threaded bolt M8 9,5 mm 4 Nm - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris + 40 C 93 % 56 days 1% 3 * 10 -4 1000 M Terminals Tab connector 6,3 mm Terminal cross section 1 mm2 Creepage distance Clearance 9 mm 7 mm Overpressure disconnector 152 Siemens Matsushita Components 1 2 B 25 834 Damping, Commutating Thermal data B25834-F6104-M001 Dielectric power dissipation PD versus repetition frequency f0 uac = 900 V uac = 810 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 41 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 153 B 25 834 Damping, Commutating 1 F / 900 Vac Ordering code: B25834-F6105-K001 Characteristics 1 F 20 % AC 900 V AC 780 V 16 A 50 nH 2 * 10 -4 12 m 18 max. Tab connector A 6,3 x 0,8 DIN 46 244 CN, tol. UN Ui Imax Lself tan 0 RS 8+1 482 M8 Maximum ratings u us i Is (du/dt)max (du/dt)s Test data 1100 V 1500 V 300 A 750 A 300 V/s 750 V/s 15,50,5 KLK1435-2 _ 0,2 30 +0,5 UTT UTC Ris tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1150 V, 10 s AC 2600 V, 10 s 3000 M 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 30 mm x 48 mm 50 g Oil Threaded bolt M8 9,5 mm 4 Nm - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris + 40 C 93 % 56 days 1% 3 * 10 -4 1000 M Terminals Tab connector 6,3 mm Terminal cross section 1 mm2 Creepage distance Clearance 9 mm 7 mm Overpressure disconnector 154 Siemens Matsushita Components 1 2 B 25 834 Damping, Commutating Thermal data B25834-F6105-K001 Dielectric power dissipation PD versus repetition frequency f0 uac = 900 V uac = 810 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 15 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 155 B 25 834 Damping, Commutating 4,7 F / 900 Vac Ordering code: B25834-L6475-K009 Characteristics 4,7 F 10 % AC 900 V AC 780 V 18 A 90 nH 2 * 10 -4 9 m 17,5 max. 6,30,1 8+0,5 CN, tol. UN Ui Imax Lself tan 0 RS Maximum ratings _ 0,2 40 +0,5 u us i Is (du/dt)max (du/dt)s Test data 24 1100 V 1500 V 330 A 820 A 70 V/s 175 V/s 8+1 _2 86 +1 M8 6,8+0,2 0,80,04 KLK1432-C UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1150 V, 10 s AC 2600 V, 10 s 3000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque Terminals - 25 C + 85 C Average relative humidity 75 % 300/109 h 100000 h - 55 to + 85 C 40 mm x 86 mm 130 g Oil Threaded bolt M8 9,5 mm 4 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 3 * 10 -4 3000 s Dual tab connector 6,3 mm Terminal cross section 1,5 mm2 Creepage distance Clearance 10 mm 6 mm Overpressure disconnector 156 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-L6475-K009 Dielectric power dissipation PD versus repetition frequency f0 uac = 900 V uac = 810 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 20 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 157 B 25 834 Damping, Commutating 22 F / 900 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D6226-K004 22 F 10 % AC 900 V AC 780 V 80 A 110 nH 2 * 10 -4 2,2 m 47 _ 3 104 _ 4 75 min. 10 min. ~4 Characteristics CN, tol. UN Ui Imax Lself tan 0 RS o85,2 _ 0,4 Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1150 V, 10 s AC 2600 V, 10 s 10000 s 3 * 10 -4 89,3 _ 1,2 u us i Is (du/dt)max (du/dt)s 1100 V 1500 V 1,5 kA 3,9 kA 70 V/s 175 V/s 16+1 Maximum ratings M12 13 min. 35 KLK1436-A - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 89,3 mm x 104 mm 780 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 10 mm 10 mm Overpressure disconnector 158 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D6226-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 900 V uac = 810 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 2,7 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 159 B 25 834 Damping, Commutating 33 F / 1100 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D7336-K004 33 F 10 % AC 1100 V AC 990 V 80 A 150 nH 2 * 10 -4 2,8 m 57 _ 3 176 _ 4 135 min. 20 min. ~4 Characteristics CN, tol. UN Ui Imax Lself tan 0 RS 95,2 _ 0,4 Maximum ratings u us i Is (du/dt)max (du/dt)s Test data 1400 V 1900 V 2,6 kA 6,6 kA 80 V/s 200 V/s 99,3 _ 1,2 16+1 M12 UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1400 V, 10 s AC 3000 V, 10 s 10000 s 3 * 10 -4 13 min. 35 KLK1437-I - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 99,3 mm x 176 mm 1600 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 20 mm 13 mm Overpressure disconnector 160 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D7336-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 1100 V uac = 990 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 3,4 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 161 B 25 834 Damping, Commutating 10 F / 1400 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D0106-K004 10 F 10 % AC 1400 V AC 1300 V 80 A 150 nH 2 * 10 -4 5,2 m 57 _ 3 176 _ 4 Characteristics 135 min. CN, tol. UN Ui Imax Lself tan 0 RS 20 min. ~4 75,2 _ 0,4 Maximum ratings Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 1800 V, 10 s AC 3600 V, 10 s 10000 s 3 * 10 -4 79,2 _ 1,2 u us i Is (du/dt)max (du/dt)s 1800 V 2400 V 1,0 kA 2,5 kA 100 V/s 250 V/s 16+1 M12 13 min. 35 KLK1438-R - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 79,2 mm x 176 mm 1000 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 20 mm 13 mm Overpressure disconnector 162 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D0106-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 1400 V uac = 1260 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 6,3 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 163 B 25 834 Damping, Commutating 22 F / 1700 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D1226-K004 Characteristics 22 F 10 % AC 1700 V AC 1500 V 80 A 220 nH 2 * 10 -4 3,9 m 57 _ 3 248 _ 4 204 min. 20 min. ~4 CN, tol. UN Ui Imax Lself tan 0 RS o95,2 _ 0,4 Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 2100 V, 10 s AC 4000 V, 10 s 10000 s 3 * 10 -4 Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 99,3 _ 1,2 u us i Is (du/dt)max (du/dt)s 2100 V 2900 V 2,6 kA 6,6 kA 120 V/s 300 V/s 16+1 Maximum ratings M12 13 min. 35 KLK1414-E - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C 99,3 mm x 248 mm 2300 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 20 mm 13 mm Overpressure disconnector 164 Siemens Matsushita Components B 25 834 Damping, Commutating Thermal data B25834-D1226-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 1700 V uac = 1530 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 4,7 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 165 B 25 834 Damping, Commutating 10 F / 2100 Vac 24,5 _ 2 M10 Hex nut M10 ISO 4035 Washer 10,5 DIN 433 Ordering code: B25834-D2106-K004 10 F 10 % AC 2100 V AC 1900 V 80 A 220 nH 2 * 10 -4 5,4 m 57 _ 3 248 _ 4 20 min. 204 min. ~4 Characteristics CN, tol. UN Ui Imax Lself tan 0 RS 85,2 _ 0,4 Maximum ratings Test data UTT UTC Ris * C tan (50 Hz) Climatic data min max Humidity FQ(co) tLD(co) stg AC 2600 V, 10 s AC 4800 V, 10 s 10000 s 3 * 10 -4 89,3 _ 1,2 u us i Is (du/dt)max (du/dt)s 2600 V 3600 V 1,6 kA 4,0 kA 160 V/s 400 V/s 16+1 M12 13 min. 35 KLK1439-Z - 25 C + 85 C Average relative humidity 95 % 300/109 h 100000 h - 55 to + 85 C Design data Dimensions x l Approx. weight Impregnation Fixing Mounting hole Max. torque 89,3 mm x 248 mm 1900 g Oil Threaded bolt M12 14 mm 10 Nm IEC climatic category: 25/085/56 (IEC 68-1 and 2) test Rel. humidity ttest C /C tan Ris * C + 40 C 93 % 56 days 1% 1 * 10 -4 10000 s Terminals Screw terminals M10 Max. torque 7 Nm Terminal cross section 16 mm2 Creepage distance Clearance 20 mm 13 mm Overpressure disconnector 166 Siemens Matsushita Components B 25 834 Jump to succeding page Damping, Commutating Thermal data B25834-D2106-K004 Dielectric power dissipation PD versus repetition frequency f0 uac = 2100 V uac = 1890 V Ohmic power dissipation PR versus rms current value I RS (85 C) = 6,5 m Permissible ambient temperature A versus total power dissipation P (Upright mounting position) Natural cooling Forced cooling 2 m/s Permissible capacitor temperature Siemens Matsushita Components 167 |
Price & Availability of B25834-L6106-K9
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |