![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Electronic Twin Timer Multirange timer with independent on and off times from 0.05 sec. to 60 hours each I Timing ranges 0.05 sec to 60 hours I 16 timing ranges, front panel selectable I Indications for time range, output status and power on I DPCO output relay I Easy-set dual concentric knob I Independent on/off time units I 48-DIN I Plug-in octal base I Sockets available for panel, surface or rail mounting I Approved by standards: UL and CSA TA8-TA M New od els Guarantee Year 3 Ordering code T A 8 - TA 2 4 V A C / D C T A 8 - TA 1 0 0 - 2 4 0 V A C Specifications Timing ranges (selectable) Calibrated timing range 0-6 0-12 0-30 0-60 Controlled timing range Time unit: 0.1 sec. 0.05-0.6 sec. 0.1-1.2 0.25-3 0.5-6 Time unit: sec. 0.5-6 sec. 1-12 2.5-30 5-60 Time unit: min. 0.5-6 min. 1-12 2.5-30 5-60 Time unit: hrs. 0.5-6 hr. 1-12 2.5-30 5-60 Repeat accuracy Max. switching frequency Allowable ambient temperature Mechanical life Electrical life Allowable operating voltage range Contact ratings Power consumption Supply frequency Dielectric strength Insulation resistance Vibration Shock 0.3% at max. setting time 1800 times/hour -10C to +55C (Avoid icing) 20 million operations or more 100,000 operations or more at 250 V AC 5A resistive load 0.85 to 1.1 times input voltage (0.9 to 1.1 at 55C) 5A at 250 V AC resistive load 10VA at 240 V AC 50/60 Hz 2,000 V AC rms. 1 min. between current carrying part and non current carrying part 2,000 V AC rms. 1 min. between output contacts and control circuit 1,000 V AC rms. 1 min. between open contacts 100 M or more at 500 V DC megger Mechanical durability: 10 to 55Hz, 0.75mm double amplitude Malfunction durability: 10 to 55Hz, 0.5mm double amplitude Mechanical durability: 500m/S2 (Approx. 50G) Malfunction durability: 100m/S2 (Approx. 10G) Telephone: +44 (0)208 452 6444 IMOnline: www.imopc.com TA8-TA Timing and wiring diagrams TA8-A Power Timed NO Timed NC LED POWER LED OUTPUT 2-7 1-3 8-6 1-4 8-5 T * When power is applied, the NO timed contacts make after the set time has elapsed. * When power is removed the timer resets. TA8-SA Power Timed NO Timed NC Inst. NO Inst. NC LED POWER LED OUTPUT 2-7 T 8-6 8-5 1-3 1-4 * Timed contact When power is applied, the NO contact makes after the set time has elapsed. When power is removed, the timer resets. * Instantaneous contact When power is applied, the NO contact makes instantly. When power is removed, the timer resets. * When power (2-7) is ON, the NO timed contacts (1-3, 8-6) are instantly closed. When power is OFF, they are opened after the set time has elapsed. TA8-DA Power 2-7 Timed NO 1-3 8-6 Timed NC 1-4 8-5 TA8-TA Power Timed NO Timed NC 2-7 1-3 8-6 1-4 8-5 * When power (2-7) is ON, the NO (1-3, 8-6) and the NC (1-4, 8-5) timed contacts are alternately closed to repeat the ON-OFF operations. * When power is OFF the timer resets. LED POWER LED OUTPUT Dimensions (mm) Flush mounting panel cut-out Adaptor CTB Net weight : Approx. 15g Note: Net weight : Approx. 100g For flush mounting, an adaptor CTB is required (sold separately). When ordering, specify the adaptor type. Sockets Surface/track mounting - screw terminal STD-8 Flush mounting - screw terminal Net weight : Approx. 40g STF-8 Net weight : Approx. 50g Flush mounting - solder terminal ZSV8 Telephone: +44 (0)208 452 6444 IMOnline: www.imopc.com |
Price & Availability of STF8
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |