 PolySwitch Resettable Devices - Telecommunications & Networking Devices
PolySwitch Resettable Devices Telecommunications & Networking Devices
PolySwitch devices for telecommunication and networking applications were initially designed over ten years ago to meet the growing demand for resettable overcurrent protection. These product families help provide protection against power cross and power induction surges as defined in ITU, Telcordia GR1089, and UL60950. Available in chip, surface-mount, and radial-leaded configurations, PolySwitch devices help improve the reliability of customer premise and network equipment world wide.
Benefits
* Many product choices give engineers more design flexibility * Compatible with high volume electronics assembly * Assist in meeting regulatory equipment requirements * Improved line balance * Applicable for legacy POTS and modern digital communications equipment
Features
* RoHS compliant * Resettable overcurrent protection * Surface-mount, radial-leaded, and chip form factors * Fast time-to-trip * Agency recognition: UL, CSA, TUV * Resistance sorted and matched devices available * Low parasitic capacitance/flat impedance with frequency
Applications
* Modems * Phone sets * Fax machines * Phone wall outlets * Alarm systems * PBX systems * MDF modules * Analog and digital line cards * T1/E1 equipment * xDSL modems and splitters * Powered ethernet systems * VoIP (Voice over IP equipment) * LAN, WAN equipment * Customer premise equipment * Access network hardware
15
221
Protection Application Guide for Telecommunications and Networking Devices*
To use this guide, follow the steps below: 1. Select your equipment type from the guide below. 2. Select the type of protection depending on the agency and regional specifications in the second column. 3. Select the form factor for your application. 4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application based on the agency requirements. 5. Parts with fast time-to-trip or low resistance are available. Please consult a Tyco Electronics Circuit Protection product representative.
Overcurrent Protection Region/ Specification North America TIA-968-A, UL 60950, GR1089 Port Type 3 Europe/Asia/ South America ITU K.21 TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 Access network equipment () Remote terminals, line repeaters, multiplexers, cross-connects, WAN equipment North America GR1089 Port Type 5 TRF600-160 TRF600-400 TS600-170F TS600-200F TS600-400F TSM600-250F TSM600-400F FT600-1250 Europe/Asia/ South America ITU K.45 TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 Central office switching equipment () Analog/POTS linecards, ISDN linecards, xDSL modems, ADSL/VDSL splitters, T1/E1 linecards, multiplexers, CSU/DSU, servers Europe/Asia/ South America ITU K.20 TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 Primary protection modules () MDF modules, Network Interface Devices (NID) North America Telcordia GR-974 Europe/Asia/ South America ITU K.20 TRF250-183 TRF250-184 TRF250-080U TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 Short-haul/intrabuilding communications equipment () LAN equipment, VoIP cards, cable telephony NIUs, wireless local loop handsets Europe/Asia/ South America ITU K.21 North America GR1089 Port Type 2 GR1089 Port Type 4 TRF250-080U TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 TS250-130F TSV250-130F TVBxxx(N)SA-L TVAxxx(N)SA-L TSL250-080F TS250-130F TSV250-130F TVBxxx(N)SA-L TVAxxx(N)SA-L TSL250-080F TS250-130F TSV250-130F TCF250-100T TCF250-120T TCF250-145T TCF250-180 TVBxxx(N)SA-L TVBxxx(N)SB-L TVBxxx(N)SC-L N/A North America GR1089 Port Type 1 TRF600-160 TRF600-400 TS600-170F TS600-200F TS600-400F TSM600-250F TSM600-400F FT600-1250 TS250-130F TSV250-130F TCF250-180 TVBxxx(N)SA-L TVAxxx(N)SA-L TVBxxx(N)SC-L TS250-130F TSV250-130F TVBxxx(N)SA-L TVAxxx(N)SA-L TVBxxx(N)SC-L Form Factor Radial-leaded TRF600-150 TRF600-160 TRF600-400 Surface-mount TS600-170F TS600-200F TSM600-250F TSM600-400F TS250-130F TSV250-130F TVBxxx(N)SA-L TVAxxx(N)SA-L Chip Overvoltage Protection SiBar Thyristor Surge Protectors** TVBxxx(N)SA-L TVBxxx(N)SB-L TVAxxx(N)SA-L
Application Customer Premises equipment IT equipment Analog modems, V.90 modems, ISDN modems, xDSL modems, ADSL splitters, phone sets, fax machines, answering machines, caller ID, internet appliances, PBX systems, POS terminals, wall plugs
15
222
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Protection Application Guide for Telecommunications and Networking Devices*
Overcurrent Protection Region/ Specification North America GR1089 Port Type 4 Form Factor Radial-leaded TRF250-080U TRF250-120 TRF250-120T TRF250-145 TRF250-183 TRF250-184 IEEE 802.3AF/AT Power over ethernet protection Powered ethernet switches and terminals, IP phones, wireless LAN base stations, microcellular base stations, VoIP cards Cable telephony powering system Power passing taps BBRF550*** BBRF750*** N/A decaSMDC050F/60-2 Surface-mount TSL250-080F TS250-130F TSV250-130F Chip
... Cont'd
Overvoltage Protection SiBar Thyristor Surge Protectors** TVBxxx(N)SA-L TVAxxx(N)SA-L
Application LAN intrabuilding power cross protection LAN equipment, VoIP cards, IP phones
TVB058(N)SA-L TVB058NSB-L TVB058NSC-L
* This list is not exhaustive. Tyco Electronics welcomes our customers' input for additional application ideas for PolySwitch resettable devices. For improved line balance in these applications, resistance-matched parts are recommended. May require additional impedance or coordination with primary protector. ** For more information on Raychem Circuit Protection SiBar thyristor surge protectors, refer to the SiBar Thyristor Surge Protectors Section. FT600-1250 are surface mount telecom fuse devices. FT600-0500 and FT600-2000 reference also available. See Telecom Fuses Section. For details on decaSMDC050F/60-2, see Surface-mount Devices Section. *** For details on BBRF series, see Radial-leaded Devices Section.
Agency Specification/Selection Guide for Telecommunications and Networking Devices
Use the guide below to select the PolySwitch devices which are typically used in your application. The following pages contain the specifications for the part numbers recommended below. PolySwitch devices assist telecommunication equipment in meeting the applicable protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics. Users should independently evaluate the suitability of, and test each product for their application.
Family TCF250 Product* TCF250-100T Lightning ITU K.20 - 1.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level Power Cross/Contact/Induction PRC YD/T694 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s GR-1089 Port Type 4 - 120VAC, 25Asc TCF250-120T TCF250-145T TCF250-180 ITU K.20/21/45 - 1.5kV 10/700s ITU K.20/21/45 - 4.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level ITU K.20/21/45 - 230VAC, 10 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s ITU K.20/21/45 - 10A2s GR-1089 Port Type 4 - 120VAC, 25Asc
* ** Applies to all products which share the same prefix. Tested with 230V gas discharge tube primary protector. Tested with 350V gas discharge tube primary protector. See SCD for additional application fault ratings. May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000s). See Telecom Fuses Section.
15
223
Agency Specification/Selection Guide for Telecommunications and Networking Devices
Family TRF250 Product* TRF250-080U Lightning ITU K.20 - 1.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level Power Cross/Contact/Induction ITU K.20 - 230VAC, 10 ITU K.20 - 0.2A2s ITU K.20 - 1A2s GR-1089 Port Type 4 - 120VAC, 25Asc TRF250-110U TRF250-120 TRF250-120T TRF250-120U TRF250-120UT TRF250-145 TRF250-145U TRF250-183 TRF250-184 ITU K.20/21/45 - 1.5kV 10/700s ITU K.20/21/45 - 4.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level ITU K.20/21/45 - 230VAC, 10 ** ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s ITU K.20/21/45 - 10A2s GR-1089 Port Type 4 - 120VAC, 25Asc TS250/TSV250 TSV250-130F TS250-130F ITU K.20/21/45 - 1.5kV 10/700s ITU K.20/21/45 - 4.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level ITU K.20/21/45 - 230VAC, 10 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s ITU K.20/21/45 - 10A2s GR-1089 Port Type 4 - 120VAC, 25Asc TS250-130F-RB ITU K.20/21/45 - 1.5kV 10/700s ITU K.20/21/45 - 4.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level ITU K.20/21/45 - 230VAC, 10 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s ITU K.20/21/45 - 10A2s GR-1089 Port Type 4 - 120VAC, 25Asc TSL250 TSL250-080F GR-1089 Port Types 2 & 4 - 1st Level ITU K.20 - 1.0kV 10/700s GR-1089 Port Type 4 - 120VAC, 25Asc ITU K.20/21/45 - 230VAC, 10 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s TRF600 TRF600-150 TRF600-160 TRF600-400 TS600 TS600-170F TS600-200F-RA TIA-968-A Types A & B UL60950 - 600VAC, 40Asc ITU K.20/21/45 - 1.5kV 10/700s ITU K.20/21/45 - 4.0kV 10/700s GR-1089 Port Types 2 & 4 - 1st Level ITU K.20/21/45 - 230VAC, 10 ITU K.20/21/45 - 0.2A2s ITU K.20/21/45 - 1A2s ITU K.20/21/45 - 10A2s GR-1089 Port Type 4 - 120VAC, 25Asc
... Cont'd
GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level Telcordia GR-1089 - 600VAC, 60Asc GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level TIA-968-A Types A & B Telcordia GR-1089 - 600VAC, 60Asc UL60950 - 600VAC, 40Asc
GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level Telcordia GR-1089 - 600VAC, 60Asc
15
TSM600
TS600-400F TSM600-250F TSM600-250F-RA TSM600-400F TIA-968-A Types A & B UL60950 - 600VAC, 40Asc
GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level Telcordia GR-1089 - 600VAC, 60Asc TIA-968-A Types A & B GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level UL60950 - 600VAC, 40Asc Telcordia GR-1089 - 600VAC, 60Asc UL60950 - 600VAC, 40Asc
FT600
FT600-0500 FT600-1250 FT600-2000
TIA-968-A - Types A & B
GR-1089 Port Types 1, 3, & 5 - 1st & 2nd Level
Telcordia GR-1089 - 600VAC, 60Asc
* **
Applies to all products which share the same prefix. Tested with 230V gas discharge tube primary protector. Tested with 350V gas discharge tube primary protector. See SCD for additional application fault ratings. May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000s). See Telecom Fuses Section.
224
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Table T1
Product Series: Size, Current Rating, Voltage Rating, Typical Resistance for Telecommunications and Networking Devices
TS600 TSM600 600
TCF250 Voltage Rating (VAC)* (Interrupt) 250
TRF250 250
TS250 250
TSV250 250
TSL250 250
TRF600 600
Specification Hold Current (A) 0.080 0.100 0.110 0.120 0.130 0.145 0.150 0.160 0.170 0.183 0.184 0.200 0.250 0.400
ITU GR-1089 Ports 2 & 4
ITU GR-1089 Ports 2 & 4
ITU GR-1089 Ports 2 & 4
ITU GR-1089 Ports 2 & 4
GR-1089 Ports 2 & 4
UL60950 GR-1089 Ports 1, 3, & 5
UL60950 GR-1089 Ports 1, 3, & 5
-- 11.0 -- 10.5 -- 7.0 -- -- -- -- -- -- -- --
17.0 -- 7.0 8.0 -- 4.5 -- -- -- 1.3 1.9 -- -- --
-- -- -- -- 9.0 -- -- -- -- -- -- -- -- --
-- -- -- -- 5.5 -- -- -- -- -- -- -- -- --
8.0 -- -- -- -- -- -- -- -- -- -- -- -- --
-- -- -- -- -- -- -- -- 11.0 -- -- 8.5 3.5 1.2
-- -- -- -- -- -- 8.0 6.0 -- -- -- -- -- 1.2
Voltage Ratings for Telecommunications and Networking Devices For Raychem Circuit Protection telecommunications devices there are two applicable voltage ratings. These are VMax Operating and VMax Interrupt. To help understand the nature of these two different voltage ratings, the following definitions are provided: VMax Operating : For telecommunications devices this is the voltage used to obtain component recognition under UL1434. Most Raychem Circuit Protection devices are certified at 60V but can withstand higher VMax Interrupt conditions as noted above. See Table T3 for its VMax Operating. *VMax Interrupt : Under specified conditions this is the highest voltage that can be applied to the device at the maximum current. Devices have been designed to trip safely under higher power level cross conditions, as listed above, to assist equipment in meeting the appropriate industry conditions.
15
225
Table T2
Thermal Derating for Telecommunications and Networking Devices [Hold Current (A) at Ambient Temperature (C)]
Maximum Ambient Temperature
Part Number Chip* -- 250VAC TCF250 TCF250-100T TCF250-120T TCF250-145T TCF250-180 Radial-leaded* -- 250VAC TRF250 TRF250-080U TRF250-110U TRF250-120 TRF250-145
NEW NEW
-40C
-20C
0C
20C
40C
50C
60C
70C
85C
0.155 0.186 0.225 0.269
0.138 0.165 0.199 0.240
0.119 0.143 0.172 0.211
0.100 0.120 0.145 0.180
0.083 0.099 0.119 0.153
0.073 0.088 0.106 0.138
0.064 0.077 0.093 0.123
0.055 0.066 0.080 0.109
0.042 0.050 0.060 0.087
0.124 0.171 0.186 0.225 0.284 0.286
0.110 0.151 0.165 0.199 0.251 0.252
0.095 0.131 0.143 0.172 0.217 0.218
0.080 0.110 0.120 0.145 0.183 0.184
0.066 0.091 0.099 0.119 0.149 0.150
0.059 0.081 0.088 0.106 0.133 0.134
0.051 0.071 0.077 0.093 0.117 0.118
0.044 0.061 0.066 0.080 0.101 0.102
0.033 0.046 0.050 0.060 0.075 0.075
TRF250-183 TRF250-184 Surface-mount* -- 250VAC TS250/TSL250/TSV250 TSL250-080F TS250-130F TSV250-130F Radial-leaded -- 600VAC TRF600 TRF600-150 TRF600-160
0.124 0.208 0.208
0.110 0.182 0.182
0.095 0.156 0.156
0.080 0.130 0.130
0.066 0.104 0.104
0.059 0.091 0.091
0.051 0.078 0.078
0.044 0.065 0.065
0.033 0.045 0.045
0.233 0.249 0.640
0.206 0.219 0.560
0.178 0.190 0.480
0.150 0.160 0.400
0.124 0.132 0.320
0.110 0.117 0.270
0.096 0.103 0.230
0.083 0.088 0.190
0.062 0.066 0.130
NEW
TRF600-400 Surface-mount -- 600VAC TS600/TSM600 TS600-170F TS600-200F-RA-B-0.5
0.264 0.310 0.640 0.400 0.400 0.640
0.230 0.275 0.560 0.350 0.350 0.560
0.200 0.238 0.480 0.300 0.300 0.480
0.170 0.200 0.400 0.250 0.250 0.400
0.140 0.165 0.320 0.198 0.198 0.320
0.125 0.147 0.270 0.170 0.170 0.270
0.109 0.128 0.230 0.140 0.140 0.230
0.094 0.110 0.190 0.117 0.117 0.190
0.070 0.083 0.130 0.083 0.083 0.130
NEW
TS600-400F TSM600-250F TSM600-250F-RA TSM600-400F
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Product is not currently available in a resistance matched or sorted option.
Figure T1 Thermal Derating [Hold Current (A) at Ambient Temperature (C)]
15
A B
= =
TCF250-180 All other TCF TRF , , TSx, TSM series devices
Figure T1
200
% of Rated Hold and Trip Current
B
150
A
100
50
A B
0
-40
-20
0
20
40
60
80
Device's Ambient Temperature (C)
226
RoHS compliant, ELV compliant
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Table T3 Electrical Characteristics for Telecommunications and Networking Devices
Part Number IH (A) IT (A) VMax Operating Interrupt (VDC) (VRMS) IMax* Interrupt (A) PD TYP (W) Typical Time-to-trip (s) (A) RMin () RMax () R1 Max ()
NEW NEW
NEW
NEW
Chip* -- 250VAC TCF250 0.100 TCF250-100T 0.120 TCF250-120T TCF250-145T 0.145 0.180 TCF250-180 Radial-leaded* -- 250VAC TRF250 0.080 TRF250-080T 0.080 TRF250-080U TRF250-110U 0.110 TRF250-120 0.120 0.120 TRF250-120T 0.120 TRF250-120T-RA TRF250-120T-RC 0.130 TRF250-120T-RF 0.120 0.120 TRF250-120T-R1 TRF250-120T-R2 0.120 TRF250-120U 0.120 TRF250-120UT 0.120 TRF250-145 0.145 0.145 TRF250-145-RA 0.145 TRF250-145-RB TRF250-145T 0.145 TRF250-145U 0.145 0.183 TRF250-183 TRF250-184 0.184 Surface-mount* -- 250VAC TS250/TSL250/TSV250 TSL250-080F 0.080 TS250-130F 0.130 -- TS250-130F-RA 0.130 -- TS250-130F-RB 0.130 -- TS250-130F-RC 0.130 -- TSV250-130F 0.130 Radial-leaded -- 600VAC TRF600 TRF600-150 0.150 TRF600-150-RB 0.130 TRF600-160 0.160 TRF600-160-RA 0.160 TRF600-160-R1 0.160 TRF600-400 0.400 Surface-mount -- 600VAC TS600/TSM600 TS600-170F 0.170 TS600-200F-RA-B-0.5 0.200 TS600-400F 0.400 TSM600-250F 0.250 TSM600-250F-RA 0.250 TSM600-400F 0.400
0.150 0.240 0.290 0.650
60 60 60 60
250 250 250 250
3.0 3.0 3.0 3.0
0.6 1.0 1.0 0.9
1.0 1.0 1.0 1.0
0.2 0.6 1.5 15.5
14.0 6.3 5.0 1.0
18.0 12.0 9.0 2.2
24.0 18.0 14.0 4.0
0.160 0.160 0.220 0.240 0.240 0.240 0.260 0.240 0.240 0.240 0.240 0.240 0.290 0.290 0.290 0.290 0.290 0.685 1.000
60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 100 100
250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250
3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 10.0 10.0
0.6 0.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.9 0.9
0.35 0.35 1.00 1.00 0.35 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 3.00 3.00
2.5 2.5 0.8 1.5 0.7 1.2 1.5 0.9 1.0 0.8 1.0 0.7 2.5 2.5 2.0 1.5 2.0 0.6 0.5
15.0 14.0 5.0 4.0 7.0 7.0 5.4 6.0 6.0 8.0 6.0 7.0 3.0 3.0 4.5 5.4 3.5 0.8 1.2
22.0 20.0 9.0 8.0 12.0 9.0 7.5 10.5 9.0 10.5 10.0 12.0 6.0 5.5 6.0 7.5 6.5 2.2 2.4
33.0 33.0 16.0 16.0 16.0 16.0 14.0 16.0 16.0 16.0 16.0 16.0 14.0 12.0 14.0 14.0 14.0 3.4 3.1
0.160 0.260 -- 0.260 -- 0.260 -- 0.260 -- 0.260
80 60 60 60 60 60 60 60 60 60
250 250 600 250 600 250 600 250 600 250
3.0 3.0 1.0 3.0 1.0 3.0 1.0 3.0 1.0 3.0
1.2 1.1 -- 1.1 -- 1.1 -- 1.1 -- 1.5
1.0 1.0 -- 1.0 -- 1.0 -- 1.0 -- 1.0
0.8 0.9 -- 1.4 -- 0.7 -- 1.1 -- 2.0
5.0 6.5 -- 6.5 -- 9.0 -- 7.0 -- 4.0
11.0 12.0 -- 9.0 -- 12.0 -- 10.0 -- 7.0
20.0** 20.0** -- 15.0** -- 20.0** -- 17.0** -- 12.0**
0.300 0.260 0.320 0.320 0.320 1.000
250 250 250 250 250 60
600 600 600 600 600 600
3.0 3.0 3.0 3.0 3.0 3.0
1.0 1.0 1.0 1.0 1.0 2.4
1.0 1.0 1.0 1.0 1.0 3.0
1.4 1.0 7.5 9.5 9.0 4.0
6.0 9.0 4.0 4.0 4.0 0.95
10.0 12.0 10.0 7.0 8.0 1.45
17.0 22.0 18.0 16.0 17.0 1.90
15
0.400 0.400 1.000 0.860 0.860 1.000 60 60 60 250 250 250 600 600 600 600 600 600 3.0 3.0 3.0 3.0 3.0 3.0 2.5 2.5 2.0 2.0 2.0 2.0 1.0 1.0 3.0 3.0 3.0 3.0 10.0 12.0 5.0 0.8 1.0 5.0 4.0 4.0 0.5 1.0 1.0 0.5 9.0 7.5 1.5 3.5 3.0 1.5 18.0 13.5 2.0 7.0 5.0 2.0
Notes: IH : Hold current: maximum current device will pass without interruption in 20C still air. IT : Trip current: minimum current that will switch the device from low resistance to high resistance in 20C still air. VMax Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434. VMax Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices have been designed to trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950, or GR1089 industry requirements. IMax Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434. Devices have been designed to trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950, or GR1089 industry requirements. PD : Power dissipated from device when in the tripped state in 20C still air. RMin : Minimum resistance of device as supplied at 20C unless otherwise specified. : Maximum resistance of device as supplied at 20C unless otherwise specified. RMax R1Max : Maximum resistance measured one hour post-trip or post-reflow at 20C. * ** 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Product is not currently available in a resistance matched or sorted option. R1Max measured 1 hour post-trip, or 24 hours post-reflow at 20C.
RoHS compliant, ELV compliant
227
Warning :
* Users should independently evaluate the suitability of and test each product selected for their own application. * Operation beyond the maximum volatge or current ratings or improper use may result in device damage and possible electrical arcing and flame. * The devices are intended for protection against occasional overcurrent or overtemperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. * Operation in circuits with a large inductance can generate a circuit voltage (L di/dt) above the rated voltage of the PolySwitch resettable device. This product should not be used in an application where the maximum interrupt voltage can be exceeded by inductive spikes. * A PPTC device is not a fuse - it is a nonlinear thermistor that limits current. Under a fault condition all PPTC devices go into a high resistance state but do not open circuit, so hazardous voltage may be present at PPTC locations. * Contamination of the PPTC material with certain silicon based oils or some aggressive solvents can adversely impact the performance of the devices. * Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and mechanical procedures for electronic components. * PPTC devices are not recommended to be installed in applications where the device is constrained such that its PPTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices
Figure T2
A C
Figure T3
A C
Figure T4
A
C
B
B B
D E E C to C LL C to C LL
D
Figure T5
Figure T6
A C
Figure T7
C B D B F B E D A E D
C
E
15
D
A
Figure T8
Figure T9
C
C F B E A D F D A D E G E
B
228
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Figure T2-T13 Dimension Figures for Telecommunications and Networking Devices
Figure T10
A C
... Cont'd
Figure T11
A C
Figure T12
A C
B
B
B
D
D E C to C L L E C to C L L
D
E C L
to
C L
Figure T13
A C
B
D E C to C LL
Table T4 Dimensions for Telecommunications and Networking Devices in Millimeters (Inches)
A Part Number TCF 250V* TCF250-100T TCF250-120T TCF250-145T TCF250-180 TRF250 250V* TRF250-080T TRF250-080U TRF250-110U TRF250-120 TRF250-120U TRF250-145 TRF250-145U
NEW
B max min max min
C max min
D max min
E max min
F max min
G max Figure
min
4.6 (0.18) 5.4 (0.21) 5.4 (0.21) 6.9 (0.27)
4.9 (0.19) 5.6 (0.22) 5.6 (0.22) 7.1 (0.28)
4.6 (0.18) 5.4 (0.21) 5.4 (0.21) 6.9 (0.27)
4.9 (0.19) 5.6 (0.22) 5.6 (0.22) 7.1 (0.28)
2.0 (0.08) 2.0 (0.08) 2.0 (0.08) 1.3 (0.05)
2.3 (0.09) 2.3 (0.09) 2.5 (0.10) 1.6 (0.06)
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
-- -- -- --
T4 T4 T4 T4
-- -- -- -- -- -- -- -- --
TRF250-183 TRF250-184
NEW
5.8 (0.23) 4.8 (0.19) 5.3 (0.21) 6.5 (0.26) 6.0 (0.24) 6.5 (0.26) 6.0 (0.24) 7.5 (0.29) 7.7 (0.30)
-- -- -- -- -- -- -- -- --
9.9 (0.39) 9.3 (0.37) 9.4 (0.37) 11.0 (0.43) 10.0 (0.39) 11.0 (0.43) 10.0 (0.39) 10.5 (0.41) 10.5 (0.41)
-- -- -- -- -- -- -- -- --
4.6 (0.18) 3.8 (0.15) 3.8 (0.15) 4.6 (0.18) 3.8 (0.15) 4.6 (0.18) 3.8 (0.15) 4.1 (0.16) 4.6 (0.18)
4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19) 4.7 (0.19)
-- -- -- -- -- -- -- -- -- --
5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20) 5.0 (0.20)
-- -- -- -- -- -- -- -- --
-- -- -- 7.0 (0.28) 6.0 (0.24) 7.0 (0.28) 6.0 (0.24) -- --
-- -- -- -- -- -- -- -- --
-- -- -- -- -- -- -- -- --
-- -- -- -- -- -- -- -- --
T2 T11 T11 T3 T10 T3 T10 T2 T12
15
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Indicates dimension is typical, not minimum. RoHS compliant, ELV compliant
229
Table T4 Dimensions for Telecommunications and Networking Devices in Millimeters (Inches)
A Part Number TS250/TSL250/TSV250 250V* TSL250-080F TS250-130F TSV250-130F TRF600 600V TRF600-150 TRF600-160
NEW
... Cont'd
B max min max min
C max min
D max min
E max min
F max min
G max Figure
min
6.7 (0.27) 8.5 (0.34) --
7.9 (0.31) 9.4 (0.37) 6.1 (0.24)
2.7 (0.11) -- --
3.7 (0.15) 3.4 (0.14) 6.9 (0.27)
4.8 (0.19) -- --
5.3 (0.21) 7.4 (0.29) 3.2 (0.13)
0.2 (0.01) 0.3 (0.01) 0.56 (0.02)
0.4 (0.02) -- --
2.5 3.8 (0.15) --
3.1 -- 1.9 (0.08)
-- -- 1.6
-- -- 2.3
-- -- --
-- -- --
T7 T5 T6
(0.10) (0.12)
(0.07) (0.09)
-- -- --
9.0 (0.35) 16.0 (0.63) 14.8 (0.58)
-- -- --
12.5 (0.49) 12.6 (0.50) 13.1 (0.52)
-- -- --
4.6 (0.18) 6.0 (0.24) 4.6 (0.18)
4.7 (0.19) 4.7 (0.19) 4.7 (0.19)
-- -- --
5.0 (0.20) 5.0 (0.20) 5.0 (0.20)
-- -- --
-- -- --
9.0 (0.35) 10.0 (0.39) --
-- -- --
-- -- --
T3 T3 T13
TRF600-400 TS600/TSM600 600V TS600-170F TS600-200F-RA
18.3 (0.72) 18.3 (0.72) 18.3 (0.72) 17.00 (0.67) 17.00 (0.67)
19.4 (0.77) 19.4 (0.77) 19.4 (0.77) 17.60 (0.69) 17.60 (0.69)
11.6 (0.46) 11.6 (0.46) 11.6 (0.46) 11.20 (0.44) 11.20 (0.44)
12.3 (0.49) 12.3 (0.49) 12.3 (0.49) 11.70 (0.46) 11.70 (0.46)
7.2 (0.29) 7.2 (0.29) 7.2 (0.29) 10.40 (0.41) 10.40 (0.41)
8.3 (0.33) 8.3 (0.33) 8.3 (0.33) 11.20 (0.44) 11.20 (0.44)
1.7 (0.07) 1.7 (0.07) 1.7 (0.07) 4.80 (0.19) 4.80 (0.19)
2.4 (0.10) 2.4 (0.10) 2.4 (0.10) 5.20 (0.20) 5.20 (0.20)
9.9 9.9 9.9 2.50 2.50
10.4 10.4 10.4 2.80 2.80
1.5 1.5 1.5 0.60 0.60
2.3 2.3 2.3 1.0 1.0
-- -- -- 2.2 (0.09) 2.2 (0.09)
-- -- -- 3.1 (0.12) 3.1 (0.12)
T8 T8 T8 T9 T9
(0.39) (0.41) (0.39) (0.41) (0.39) (0.41) (0.10) (0.11) (0.10) (0.11)
(0.06) (0.09) (0.06) (0.09) (0.06) (0.09) (0.02) (0.04) (0.02) (0.04)
NEW
TS600-400F TSM600-250F TSM600-400F
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Indicates dimension is typical, not minimum.
Figure T14-T17
Typical Time-to-trip Curves at 20C for Telecommunications and Networking Devices
Figure T14
100
15
TCF250 A = TCF250-180 B = TCF250-145T C = TCF250-120T D = TCF250-100T
A
10
B C
Time-to-trip (s)
D
1
A
0.10
B C D
0.01 0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
2.80
3.00
Fault Current (A)
230
RoHS compliant, ELV compliant
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Figure T14-T17
Typical Time-to-trip Curves at 20C for Telecommunications and Networking Devices
Figure T15
... Cont'd
TRF250 A = TRF250-180/183/184 B = TRF250-145/145U C = TRF250-120/120U D = TRF250-110U/120UT/120T E = TRF250-080T/080U/080US
Time-to-trip (s)
1000
A
100
B E C D
10
1
A
0.10
B C D E
0.01 0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
1.80
2.00
2.20
2.40
2.60
2.80
3.00
Fault Current (A)
Figure T16
TS250/TSV250/TSL250 A = TSV250-130F B = TS250-130F C = TSL250-080F
100
A B
10
C
Time-to-trip (s)
1
0.10
A B C
0.01 0.00
0.50
1.00
1.50
2.00
2.50
3.00
Fault Current (A)
Figure T17
TRF600/TS600/TSM600 A = TSM600-250F B = TS600-170F/200F C = TRF600-160 D = TRF600-150 E = TRF600-400/TS600-400/TSM600-400F
Time-to-trip (s)
1000
15
C A B E
100
D
10
E
1
A B C D
0.10 0.00
0.50
1.00
1.50
2.00
2.50
3.00
Fault Current (A)
231
Table T5
Physical Characteristics and Environmental Specifications for Telecommunications and Networking Devices
[Operating temperature range for all listed products is -40C to 85C, except for TRF250-080T and TRF250-184 (0C to 85C)]
TCF250* Physical Characteristics
Terminal material Nickel-plated copper foil
Environmental Specifications
Test Passive aging Humidity aging Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 1000 hours 125C, -55C (10 times) MIL-STD-202, Method 215F
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TRF250* Physical Characteristics
Lead material Insulating material Flammability Soldering characteristics Solder heat withstand Tin-plated copper, 22AWG Cured epoxy polymer per IEC 695-2-2 Needle Flame Test for 20s ANSI/J-STD-002, Category 3 IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260C5C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test Passive aging Humidity aging Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 1000 hours 125C, -55C (10 times) MIL-STD-202, Method 215F
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TS250/TSV250/TSL250* Physical Characteristics
Terminal material Soldering characteristics Tin-plated brass, Nickel under-plating EIC 60008-2-58
15
Environmental Specifications
Test Passive aging Humidity aging Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 500 hours 125C, -55C (10 times) MIL-STD-202, Method 215F
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85C/85% RH or 1000h at 60C/90% RH.
232
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Table T5
Physical Characteristics and Environmental Specifications for Telecommunications and Networking Devices
... Cont'd
[Operating temperature range for all listed products is -40C to 85C, except for TRF250-080T and TRF250-184 (0C to 85C)]
TRF600 Physical Characteristics
Lead material Insulating material Flammability Soldering characteristics Solder heat withstand Tin-plated copper, 22AWG Cured epoxy polymer per IEC 695-2-2 Needle flame test for 20s ANSI/J-STD-002, Category 3 IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: can withstand 10 seconds at 260C5C
Note: Devices are not designed to be placed through a reflow process.
Environmental Specifications
Test Passive aging Humidity aging Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 1000 hours 125C, -55C (10 times) MIL-STD-202, Method 215F
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TS600 Physical Characteristics
Terminal material Insulating material Flammability Soldering characteristics Solder heat withstand Tin-plated brass Nylon resin (UL94V-0), 1000V dielectric rating IEC 695-2-2 Needle Flame Test for 20s ANSI/J-STD-002, Category 3 IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
Environmental Specifications
Test Passive aging Humidity aging Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 1000 hours 125C, -55C (10 times) MIL-STD-202, Method 215F
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
TSM600 Physical Characteristics
Terminal material Insulating material Flammability Soldering characteristics Solder heat withstand Tin-plated brass Nylon resin (UL94V-0), 1000V dielectric rating IEC 695-2-2 Needle Flame Test for 20s EIC60068-2-58, Method 7 IEC-STD 68-2-20, Test Tb, Section 5 Method 1A
15
Environmental Specifications
Test Passive aging Humidity aging Storage humidity Thermal shock Solvent resistance Conditions 60C, 1000 hours 85C, 1000 hours 85C, 85% RH, 1000 hours IPer IPC/JEDEC J-STD-020A Level 2a 125C, -55C (10 times) MIL-STD-202, Method 215J
Note: Storage conditions: 40C max., 70% RH max., devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded.
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements. Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85C/85% RH or 1000h at 60C/90% RH.
233
Table T6 Packaging and Marking Information for Telecommunications and Networking Devices
Bag Quantity Tape & Reel Quantity Standard Package Quantity
Part Number Chip* -- 250VAC TCF250 TCF250-100T TCF250-120T TCF250-145T TCF250-180 Radial-leaded* -- 250VAC TRF250 TRF250-080U TRF250-080U-2 TRF250-080T TRF250-110U TRF250-110U-2 TRF250-120 TRF250-120-2 TRF250-120T TRF250-120T-2 TRF250-120U TRF250-120U-2 TRF250-120UT TRF250-145 TRF250-145-2 TRF250-145-RA TRF250-145U TRF250-145U-2
NEW NEW NEW
Part Marking
Agency Recognition
2,500 2,500 2,500 2,500
-- -- -- --
10,000 10,000 10,000 10,000
-- -- -- --
-- -- -- UL
500 -- 500 500 -- 500 -- 500 -- 500 -- 500 500 -- 500 500 -- 500 -- 500
-- 1,500 -- -- 1,500 -- 1,500 -- 1,500 -- 1,500 -- -- 1,500 -- -- 1,500 -- 1,500 --
10,000 7 ,500 10,000 10,000 7 ,500 10,000 7 ,500 10,000 7 ,500 10,000 7 ,500 10,000 10,000 7 ,500 10,000 10,000 7 ,500 10,000 7 ,500 10,000
-- -- 08F -- -- 20F 20F 20F 20F 20F 20F 20F 45F 45F 45F 45F 45F 83F 83F 84F
UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV
TRF250-183 TRF250-183-2 TRF250-184 Surface-mount* -- 250VAC TS250/TSL250/TSV250 TSL250-080F-2 TS250-130F-2 TSV250-130F-2 Radial-leaded -- 600VAC TRF600 TRF600-150 TRF600-150-2 TRF600-160 TRF600-160-2
-- -- --
1,500 1,500 1,200
7 ,500 7 ,500 6,000
T08 T13 T13V
UL,CSA,TUV UL, CSA, TUV UL, CSA, TUV
500 -- 500 -- 500
-- 1,500 -- 600 --
10,000 7 ,500 10,000 3,000 10,000
150F 150F 160F 160F 400F
UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA, TUV UL, CSA
NEW
15
NEW
TRF600-400 Surface-mount -- 600VAC TS600/TSM600 TS600-170F-2 TS600-200F-RA-2 TS600-400F-2 TSM600-250F-2 TSM600-250F-RA-2 TSM600-400F-2
-- -- -- -- -- --
300 300 300 200 200 200
900 900 900 1,000 1,000 1,000
T20 T20 T40 TSM600 TSM600 TSM600
UL, CSA UL, CSA UL, CSA UL, CSA UL, CSA UL
* 250VAC interrupt products are designed to help equipment pass ITU K.20, K.21, & K.45 recommendations and Telcordia GR-1089 Port Type 2 & 4 requirements. 600VAC interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 & 5 requirements.
234
RoHS compliant, ELV compliant
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Agency Recognition for Telecommunications and Networking Devices
UL CSA TUV File # E74889 File #78165C Per IEC60730-1
Certificate # for individual products available upon request.
Table T7
Device TS250 (All) TSV250 (All) TSL250 (All) TS600 (All) TSM600 (All)
Recommended Pad Layouts for Surface-mount Telecommunications and Networking Devices in millimeters (inches) Nominal
A 4.60 (0.180) 2.29 (0.090) 3.60 (0.140) 10.42 (0.410) 5.20 (0.205) B 1.80 (0.070) 2.41 (0.095) 1.80 (0.070) 3.30 (0.130) 17.80 (0.701) C 6.10 (0.240) 6.35 (0.250) 5.50 (0.220) 3.35 (0.132) 5.54 (0.218) D -- -- 3.43 (0.135) -- -- -- -- 6.75 (0.266) E -- -- -- -- -- -- -- -- 2.08 (0.082) F -- -- -- -- -- -- -- -- 3.12 (0.123) G -- -- -- -- -- -- -- -- 8.39 (0.331) Figure T18 T19 T18 T18 T20
Figure T18
Figure T19
Figure T20
B
A A B B C B C B A
D A EG F C D
Solder Reflow and Rework Recommendations for Telecommunications Surface-mount Devices
Solder Reflow * Recommended reflow method: IR, vapor phase oven, hot air oven. * Surface-mount devices are not designed to be wave soldered to the bottom side of the board. * Recommended maximum paste thickness of 0.25mm (0.010 in). * Devices can be cleaned using standard industry methods and solvents. Rework * If a device is removed from the board, it should be discarded and replaced with a new device.
Figure T21
300 Temperature (C) 250 200 150 100 50 0 30-90 10 to 20 Time (s) 120
Preheating
Soldering
Cooling
15
Wave Soldering and Rework Recommendations for Telecommunications Radial-leaded Devices
Recommended Wave Soldering * Soldering temperature profile Temperature characteristic at component terminal with dual wave soldering Rework * If a device is removed from the board, it should be discarded and replaced with a new device.
Figure T22
300 250 245C ... 260C Temperature (C) 200 150 100 50 0
100C ... 130C Forced cooling 10s
0
50
100 Time (s)
150
200
250
235
Table T8
TRF250/TRF600 Tape and Reel Specifications for Telecommunications and Networking Device
TRF250/TRF600 devices are available in tape and reel packaging per EIA 468-B standard. See Figures T23 and T24 for details.
Dimension Description Carrier tape width Hold down tape width Top distance between tape edges Sprocket hole position Sprocket hole diameter Abcissa to plane (straight lead) Abcissa to plane (kinked lead)* Abcissa to top Overall width w/lead protrusion Overall width w/o lead protrusion Lead protrusion Protrusion of cut-out Protrusion beyond hold down tape Sprocket hole pitch Device pitch: TRF250 & TRF600-150 Device pitch: TRF600-160/400 Pitch tolerance Tape thickness Tape thickness with splice* Splice sprocket hole alignment Body lateral deviation Body tape plane deviation Lead spacing plane deviation Lead spacing* Reel width Reel diameter Space between flanges less device Arbor hole diameter Core diameter Box Consecutive missing pieces* Empty places per reel*
* Differs from EIA specification.
EIA Mark W W4 W6 W5 D0 H H0 H1 -- -- L1 L I2 P0 -- -- -- t t1 -- h p P1 F w2 a w1 c n -- -- --
IEC Mark W W0 W2 W1 D0 H H0 H1 C1 C2 I1 L I2 P0 -- -- -- t -- -- h p P1 F w d -- f h -- -- --
Dimension (mm) 18 5 3 9 4 18.5 16 32.2 43.2 42.5 1.0 11 Not specified 12.7 12.7 25.4 20 consecutive 0.9 2.0 0 0 0 0 5.08 56 370 4.75 26 80 56/372/372 3 maximum Not specified
Tolerance -0.5/+1.0 Minimum Maximum -0.5/+0.75 0.2 3.0 -0.5/+0.6 Maximum Maximum Maximum Maximum Maximum -- 0.3 -- -- 1 Maximum Maximum 0.3 1.0 1.3 0.7 0.6 Maximum Maximum 3.25 12.0 Maximum Maximum -- --
15
236
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Figure T23 EIA Referenced Taped Component Dimensions for TRF Devices
h h p p
Reference plane H1 P1 F L A B W4 H0 W5 W I2 L1 P0 D0 Direction of unreeling H H1 C1 C2
Cross section A-B t
Figure T24 Reel Dimensions for TRF Devices
Reel Upper side n Type a Direction of unreeling Lower side
c
w1 w2 Cross section Optional shape: Circular or polygonal
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
TS250/TSL250/TSV250
Dimension Description Carrier tape width Sprocket hole pitch EIA Mark W P0 P1 P2 A0 B0 B1 MAX. Sprocket hole diameter D0 F E1 E2 MIN. Tape thickness Tape thickness with Splice cover tape thickness K0 Leader min. Trailer min. 3.4 300 300 0.15 -- -- 7.0 390 160 0.1 -- -- 3.70 390 160 0.10 -- -- TMAX. T1 MAX. TS250 Dimension(mm) Tolerance(mm) 16 4.0 12.0 2.0 6.9 9.6 12.1 1.5 7.5 1.75 14.25 0.4 0.1 0.30 0.10 0.10 0.10 0.23 0.15 -- -0/+0.1 0.10 0.10 -- -- -- TSV250 Dimension(mm) Tolerance(mm) 16.0 4.0 8.0 2.0 5.5 6.2 8.0 1.55 7.5 1.75 -- 0.45 0.1 0.3 0.1 0.1 0.1 0.1 0.1 -- 0.05 0.10 0.10 -- -- -- TSL250 Dimension(mm) Tolerance(mm) 16 4.0 8.0 2.0 5.5 7.9 9.2 1.55 7.5 1.75 -- 0.35 0.1 0.3 0.10 0.10 0.10 0.10 0.10 -- 0.05 0.10 0.10 -- -- --
15
237
Table T9 TS Tape and Reel Specifications for Telecommunications and Networking Devices
TS devices are packaged per EIA 481 and EIA 481-2 standards. See Figures T25 and T26 for details.
... Cont'd
TS250/TSL250/TSV250
Dimension Description Reel dimensions Reel diameter Core diameter Space between flanges less device Reel width A max. N min. W1 W2 MAX. 340 50 16.4 22.4 -- -- -0/+2.0 -- 340 50 16.4 22.4 -- -- -0/+2.0 -- 340 50 16.4 22.4 -- -- -0/+2.0 -- EIA Mark TS250 Dimension(mm) Tolerance(mm) TSV250 Dimension(mm) Tolerance(mm) TSL250 Dimension(mm) Tolerance(mm)
TS600
Dimension Description Carrier tape width Sprocket hole pitch EIA Mark W P0 P1 P2 A0 B0 B1 max. Sprocket hole diameter D0 F E1 E2 min. Tape thickness Tape thickness with splice Tmax. T1 max. K0 Leader min. Trailer min. Reel Dimensions Reel diameter Core diameter Space between flanges less device Reel width A max. N min. W1 W2 max. 360 50 32.4 40 -0/+2.0 Dimension (mm) 32 4.0 16 2.0 10 19.2 21.6 1.5 14.2 1.75 28.4 0.50 0.1 13.2 390 160 0.1 -0/+1.0 0.1 0.1 0.1 0.5 Tolerance 0.3 0.1 0.1 0.1 0.1 0.1
TSM600
Dimension Description Carrier tape width Sprocket hole pitch EIA Mark W P0 P1 P2 A0 B0 B1 max. Sprocket hole diameter D F E1 E2 min. Tape thickness Tape thickness with splice T max. T1 max. K0 Leader min. Trailer min. Reel Dimensions Reel diameter Core diameter Space between flanges less device Reel width A max. N min. W1 W2 max. 360 50 32.4 40 -0/+2.0 Dimension (mm) 32 4.0 24 2.0 11.2 17.8 23.45 1.5 14.2 1.74 28.4 0.5 0.1 11.9 390 160 0.1 -0/+1.0 0.1 0.1 0.1 0.5 Tolerance 0.3 0.1 0.1 0.1 0.1 0.1
15
238
PolySwitch Resettable Devices - Telecommunications & Networking Devices
Figure T25 EIA Referenced Taped Component Dimensions for TS Devices
P0 T D0 P2 E1 Embossment
Cover tape A0
F E2 B0
W
B1
K0
T1 Center lines of cavity
P1
Figure T26 EIA Referenced Reel Dimensions for TS Devices
W2 (measured at hub)
Cover tape
A
N (hub dia.)
Carrier tape Embossed cavity
W1 (measured at hub)
Resistance-sorted and Resistance-matched Devices
Most TCF TRF and TS devices are available in resistance-sorted and/or resistance-matched versions. ,
Resistance-sorted Devices
Resistance-sorted devices (part number suffix "Rx" where x = 1, 2, A, B, C, F etc.) are supplied with resistance values that are within , specified segments of the device's full range of resistance. Feature * Narrow resistance range. Benefits * Greater flexibility for design engineers. * Lower resistance devices can allow for increased loop length on line card designs. * Higher resistance devices may provide greater protection by offering faster time-to-trip.
15
Resistance-matched Devices
Resistance-matched devices are supplied such that all parts in one particular package (or reel) are within 0.5 of each other (1.0 for TRF250-080T devices). Individual matched packages are supplied from the full resistance range of the specified device. Feature * Tighter resistance balance between any two parts in a package. Benefits * Resistance-matched devices may reduce the tip-ring resistance differential, reducing the possibility of line imbalance.
239
Part Numbering System for Radial-leaded Telecommunications and Networking Devices
TRF*250 -120 T -RA -B-0.5 -2
Packaging 2 = Tape and Reel 0.130 = special lead length in inches (Blank) = Bulk B-x.x = Resistance matched in bins of x.x (optional) Rx = Resistance range (optional) Modifier (optional) U = Uncoated S = Straight lead T = Fast Trip device Hold Current (mA) Product Series (TRF250, TRF600)
* F = RoHS compliant, ELV compliant
Part Numbering System for Surface-mount Telecommunications and Networking Devices
TSx -200 F -RA -B-0.5 -2
Packaging = Tape and Reel 2 (Blank) = Bulk B-x.x = Resistance matched in bins of x.x (optional) Rx = Resistance range (optional) F = RoHS Compliant, ELV Compliant Hold Current (mA) Product Series (TS250, TSV250, TSL250, TS600, TSM600)
Part Numbering System for Chip Telecommunications and Networking Devices
TCF*250 -120 T -RA -B-0.5
B-x.x = Resistance matched in bins of x.x (optional) Rx = Resistance range (optional)
15
* F = RoHS compliant, ELV compliant
Modifier (optional) T = Fast Trip device Hold Current (mA) Product Series
240


▲Up To Search▲   

 
Price & Availability of TRF250-145-B-05

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X